Huayi: Professional Transformer DC Resistance Tester siamtu a ni a, a man pawh a tlawm hle.

 

A rilru a buai em em a, a rilru a hah em em bawk a. (Huayi for short) hi China rama professional manufacturer a ni a, electric testing equipment zirchiang leh siamchhuah a ni. Huayi chuan mahni inrintawkna neia hmasawn leh hralh chhuah a tum tlat a, thil siam quality tihsan, sum senso tihtlem leh efficiency tihchangtlunna kawngah theihtawp a chhuah bawk.

 

 
 
Engvangin nge min thlan .

Thil tawn hausa tak .

Company hi kum 2005 khan din a ni a, kum sawm chuang zet professional experience a nei tawh a ni. China rama high-voltage testers siamtu hmasa ber zinga mi a ni.

Professional Technology hmanga tanpui theih a ni.

Kum 18 chuang zet testing leh solutions lama specialist a ni. Mahni engineer tawnhriat ngah tak tak an awm. Professional on delivery, installation, debugging, leh training te.

ISO certification pek a ni.

Kan professional R&D technical team leh quality control khauh tak kan nei a, hei hian himna, dikna leh efficiency a neih theih nan a pui a ni. pass ISO9001 certification pass a ni a, patent certificate kaihhnawih a dawng bawk.

A hnu darkar 24 ah-Sales .

Professional after-sales service, thil siam chungchanga customer-te ngaihdan ngaihven; darkar 24 chhunga solution pek, customer-te harsatna an neih chuan; Hmanhmawh tak leh tangkai takin hma la rawh.

 

Product Parameter 1000 a ni.

 

Output current a awm em?

50a,20a,10a,5a,1a,0.2a,10mA,<1mA

Zau zawng

50 a gear 75uω-0.4Ω a ni.

20 a gear 0.5mω- 1 Ω a ni.

10 a gear 1.0mω- 2 Ω a ni.

5 a gear 10 mω- 4 Ω a ni.

1 a gear 0.1Ω- 20Ω chu a ni.

0.2a gear 1.0Ω- 100Ω a ni.

10MA Gear 50Ω- 2kΩ a ni.

<1mA gear 500Ω~ 25kΩ

Dik chiahna

±(Chhiar tur ×0.2%{{1}it)

Power supply a awm em?

AC220V±10%, 50/60Hz a ni.

Lum leh vawt tehna

-10℃-50℃a ni.

relative humidity .

<90%,No RH

Ri rin lam tehna

428mm×350mm×230mm a ni.

Buk

13.2 kg a ni.

 

50A Transformer DC Resistance Tester

 

Transformer DC Resistance Tester hmanga siam a ni.

Pawn lam casing:High-strength plastic emaw aluminum alloy emaw hmanga siam a ni a, field leh laboratory hmanna atana durability, impact resistance, leh insulation a pe thei.

 

Conductor te: 1.1.High-purity copper wire leh low-resistance terminal te hmangin tehna dik tak a awm theih nan leh power hloh tur a tih tlem theih nan.

 

Leads: 1.1.Silicone atanga siam-insulated flexible cables copper emaw gold emaw hmanga siam-plated clips, him taka hnathawh leh inzawmna nghet tak neih theihna tur.

 

Transformer DC Resistance Tester a thatna te
 

Precision testing tih a ni.
Transformer DC resistance tester hi winding resistance tehna atana siam a ni a, precision sang tak nen a ni. Hetiang level of accuracy hi transformer chhunga winding deformation emaw connection tha lo emaw ang chi thil hriatchhuahna kawngah a pawimawh hle a, test result chu enkawlna atana rintlak leh hriat tur pawimawh tak a nih theih nan a ni.

 

speed leh efficiency .
Traditional testing method chu hun-consuming a ni thei. Mahse, transformer DC tester hian winding pathumteah hian a rualin resistance a teh vek a ni. He rapid testing feature hian maintenance time nasa takin a ti tlem a, work efficiency zawng zawng a ti sang hle.

 

Portable leh on-site testing .
A design compact leh lightweight tak avangin transformer DC Resistance Tester hi phurh leh set up awlsam tak a ni. Technician-te chuan -site-ah direct-in test an nei thei a, transformer chu dedicated testing facility-a sawn a ngaihna chu an paih chhuak thei a, hei hi a bik takin remote emaw hard-to-access location-ah a hlu hle.

 

Multifunctional theihna .
Resistance testing tih lohah chuan he instrument hian transformer maintenance test dang, grounding resistance leh transformer ratio testing te pawh a handle thei a ni. He versatility hian technician te tan testing solution kimchang tak a pe a, test tam tak chu device remchang pakhatah a dah khawm a ni.

 

Automation a awm chuan a dik lo tih a tlahniam thei.
Transformer DC resistance testers tam tak chuan automated data recording leh report generation an nei a. He feature hian testing process a ti awlsam mai bakah mihring tihsual a ti tlem bawk a, a chhan chu results consistent, automatic documentation a siam theih avangin.

 

 
Transformer DC Resistance Tester hmanga industry hman dan tur .
 
01/

Power siam chhuah dan .
Power plant te hian generator lian tak tak hmangin electric an siam chhuak thin. Heng power plant te hian transformer DC resistance tester hmangin plant-a transformer awmte chu an enfiah thin a ni. User-te chu resistance chungchangah eng thil pawh an hriat theih nan an pui thin.

02/

Power sem dan .
Utility company te hian testers te hi substation-a high voltage transformer te enkawl leh test turin an hmang thin. Company-te chu transformer chhunga thil dik lo awm thei tur an hmuh theih nan an pui thin.

03/

Thil siamchhuahna .
Factory hrang hrang chu an machine power pe thei tur transformer-ah a innghat a ni. Transformer DC resistance testers te hi heng factory ah hian transformer te enfiah fo nan an hmang thin. Hei hian hnathawkte chu hmun him takah an thawk thei a ni.

04/

Aerospace 1000 a ni.
Aerospace industry hian transformer tlemte, resistance sang tak nei an hmang a. Transformer DC resistance testers te hian heng thil pawimawh tak takte hi an vawng reng thei a, thlawhnaah pawh a hlawhchham loh nan an pui bawk.

05/

Thilthawnna
Transportation system, rel leh subway ang chi te hian transformer DC resistance testers hmangin an electrical network te an enfiah thin. Tester-te hian rel-a power tihbuai lohna tur an pui a ni.

06/

Renewable Energy 1000 a ni.
Thli leh ni chakna ang chi renewable energy source a pun zel avangin heng power plant tharah hian transformer DC resistance testers te pawh hman a ni bawk. Solar panel emaw wind turbine emaw atanga DC output nena inzawm transformer te chu an vawng reng thei a ni.

 

 

Transformer DC Resistance Tester hman dan tur fimkhur dan tur .

Coil temperature a stable laiin teh la, transformer tank chunglam leh hnuai lam inkar temperature danglamna chu 3℃aia tam lo tur a ni .

 

Transformer coil inductance avang hian tehna hun chhunga charging current chu a nghet lo va, chuvangin current chu a stable hnuah counting chu tih a ngai a, a tul chuan charging time tih tawi theihna tur measures pawh lak a ngai bawk.

 

Test circuit chhunga wire awmte contact resistance tih tlem. Transformer tap hman mek hi oil film leh thil dang bawlhhlawh te hian an tawk fo thin a, chu chuan an biak theih loh phah thin. A tlangpuiin, thliar hranna dik lo awm lo turin tehna hmain vawi tam tak inthlak a ngai a ni.

 

Transformer DC resistance tester-a low-voltage lam tehnaah chuan, mi zawng zawng chuan high-voltage lam atanga him taka hlat taka awm tur a ni.

 

Transformer DC resistance tester hi transportation, storage leh work laiin vibration chak tak, direct sunlight leh magnetic field atanga ven tur a ni.

 

Instrument dahkhawm leh dahkhawm hian boruak lum leh vawt (ambient temperature and humidity) ngaihven rawh. A vawt, a luhchilh a, a ni lo, a ni lo -corrosive place-ah dah tur a ni. A hnim, ruah sur, ni chhuahna hmuna inhnimhnawih loh tur a ni. A hman hunah chuan fimkhur takin enkawl la, thlak suh.

50A Transformer DC Resistance Tester

 

Accessory 1000 a ni.

 

Hming

Zat

DC Resistance Tester Host 1000 a ni.

1

Power line a awm em?

1

Testing wire bik a awm bawk.

1

fuse a ni .

2

Standard dodalna .

1

Printing paper 100 a ni.

2

Ground wire 100 a ni.

1

Instruction hmanga zirtirna hman dan tur .

1

Certificate a ni a .

1

Warranty Card 1000 a awm bawk.

1

Packing list a awm em .

1

 

Kan thawhpui dan tur .

 

 

Chhuifiahna:Online emaw zawhna min thawn emaw theih a ni. I thil mamawh kimchang chu a chiang thei ang bera pe rawh. Chuvangin a vawi khatnaah offer chu kan rawn thawn thei ang che.
Phone number: (+86)-18062012971/WhatsApp:+8618064115448
E-Mail: sales@sinohipot.com/ tina@sinohipot.com tih a ni.

 

Custom plan siam dan: 1.1.Consultation neih chhung hian i mamawh bikte kan evaluate ang a, kan thawhhona chuan i mamawh ang zela siam custom quality assurance plan kan siam ang.

 

Inremna leh Setup:Plan-a i lungawi tawh chuan a chipchiar zawngin kan finalise ang a, a bul tanna tur zawng zawng kan set up ang.

 

Quality assurance kalpui dan tur:Chumi hnuah chuan kan team chuan i thil siam emaw, i process emaw thlan chhuahah quality assurance protocols te chu an kalpui ang.

 

Sem:Tuipuiah emaw, a tul angin thlawhna hmangin emaw cargos thawn chhuak thin ang che.

 

Packaging leh delivery .

 

 

Packing detail:

Thing cases nen packing, shipping way solution hrang hrang pe rawh.

Pe:

Payment term tam tak kan pawm a, chu chu T/T, Western Union, L/C te an ni.

Warranty hun chhung:

Pakhat-kum warranty, install leh commissioning thil chi hrang hrang.

Delivery hun chhung:

Kan thil siam tam zawk hi stock a awm a, pawisa pek hunah pawh pek theih a ni. Delivery hun hi a tlangpuiin ni 15 aia tam a ni lo.

 

productcate-1-1

 

Kan certificate te .

 

productcate-1-1

 

FAQ a ni.

Q: Engtikah nge a man hi ka hmuh theih ang?

A: A tlangpuiin i zawhna kan hmuh hnu darkar 24 chhungin kan quote thin.

Q: I order quantity minimum chu eng nge ni, sample min thawn thei ang em?

A: Kan order quantity tlem ber chu 1 set a ni a, sample shipping fee hi nangmahin i pek a ngai a ni.

Q: A products te hi stock ah i nei em .

A: Kan tester tam zawk hian stock an nei a.Stock.

Q: A thawn chhuah hmain a thil siam test a awm em?

A: Kan thil siamte hian factory testing an nei a, report nen an inzawm bawk.

Q: Discount i nei dawn em ni?

A: Yes i order quantity a zirin discount hrang hrang kan pe thei. Kum tin promotional activities mumal tak kan nei bawk.

Q: I thil siamte chu export a ni tawh em?

A: Kum 10 chuang zet export lama tawnhriat kan nei tawh a. Local partner a awm leh awm loh confirm turin min rawn biak theih reng e.

Q: Transportation chungchang hi engtin nge ni ang?

A: A tlangpuiin kawngkhar to door》delivery kan la thin ,cause a awlsam zawk a, a rang zawk bawk.

Q: Transformer DC resistance tester tehna range hian a versatility a nghawng thei em?

A: Ni e, tester, measurement range zau tak nei chuan application-ah versatility a siam a, chu chuan resistance measurement task hrang hrang atan a tha hle.

Q: Engvangin nge transformer DC resistance tester hi a chhe thei lo a pawimawh?

A: Durability hi a pawimawh ber a, tester chuan boruak khirh tak tak a tuar thei a, maintenance cost a tihtlem bakah investment atanga return tha zawk a pe thei bawk.

Q: Temperature compensation feature hian engtin nge transformer DC resistance tester a hlawkpui?

A: Temperature compensation hian boruak dinhmun hrang hranga resistance reading-te chu nasa takin a nghawng thei a, hmanrua chu parameter him leh tangkai tak chhungah a thawk thei tih a tichiang thei a ni.

Q: Engtin nge ka transformer DC resistance tester hi hun kal zelah a dikna ka vawn reng theih ang?

A: Device calibration neih fo hi a dik a, chubakah test laiin insulated connection him leh dik tak neih a nih theih nan a pawimawh hle bawk.

Q: Engvangin nge transformer DC resistance tester-ah hian tehna dikna hi a pawimawh?

A: Measurement dik tak, ±0.5% emaw a aia sang emaw hian resistance evaluation-a tihsual awm theihna a ti tlem a, hei hi hmanraw tha ber hman theihna tura pawimawh tak a ni.

Q: Transformer DC Resistance Tester thlan dawnin eng key feature nge ka ngaihtuah tur?

A: Thil pawimawh ngaihtuah tur pawimawh tak takte chu tehna range, accuracy, testing current, hman awlsam, data logging, leh connectivity option te a ni.

Q: Transformer DC resistance tester hmanga test neih lai hian eng condition nge ka ngaihtuah ang?

A: Pawn lam thil, temperature leh humidity te tih tlem nan controlled environment-a test neih a tha a, hei hian resistance readings a nghawng thei a ni.

China rama transformer DC Resistance Tester siamtu leh supplier zingah professional ber pawl kan nih angin quality product leh competitive price te hian kan feature a ni. Kan factory atang hian China rama siam transformer DC resistance tester man tlawm tak lei turin inrintawkna nei la.

Inquiry thawn rawh .
Inquiry thawn rawh .