Transformer DC Resistance Tester hmanga siam a ni
ZZC-10A DC Resistance Tester hian transformer winding leh tap-changer contact resistance - standard check a teh a, chu chu commissioning leh overhaul laiin lead weld, inter-turn shorts/open, leh tap-changer contact quality a awm leh awm loh enfiah a ni. QJ44 double bridge a thlak a: bridge-a mA-level current-in reading khatah minute a mamawhna hmunah chuan ZZC-10A hian stable DC current 100× thleng a rang zawk a pe chhuak a ni.
Four-wire Kelvin tehna chuan lead resistance a cancel. Dual LCD (4.5-digit result + 3.5-digit temp/current) te hi ni eng ah chhiar theih a ni. Automatic arc suppression hian winding chu him takin a discharge thin. 12V battery hmanga siam-a siam bakah AC/DC operation - field-ready a ni a, a size tlem berah a awm bawk.
Thil pawimawh tak tak
Multi-range DC current, instrument pakhat
Constant-current ladder 10A / 100mA / 5mA / 500μA / 50μA - hian transformer windings chu micro-ohm contact joint thlengin device switch lovin a khuh a ni.
±0.2% dikna, pali-wire tehna a ni
Current leh potential lead hrang hrang hian test-lead resistance chu reading atang hian a paih chhuak a; resolution chu 10μΩ thlengin a tlahniam a ni. Repeatable phase-to-phase tehkhin dan.
Inductive load te tan auto discharge a ni
Winding hian DC test laiin magnetic energy a khawlkhawm thin. A tawpah chuan tester chuan chu chakna chu controlled internal path hmangin a dump a - no arc back at you, no voltage spike, safe to disconnect.
AC/DC chakna pahnih, ~10 kg
Battery emaw AC 220V mains-a siam-, 15W aia tlem emaw a tlukpui emaw . Transformer bay-ah phur la, connect la, chhiar - test bench a ngai lo.
Product Parameter a ni
| Parameter a ni | A sawifiahna |
|---|---|
| Product chi hrang hrang | DC Resistance Tester a ni |
| A tehna range | 1μΩ–20kΩ |
| A dikna tehna | ±(0.2% + 2d) |
| Max resolution a ni | 1μΩ |
| Current source awm reng | 10A / 100mA / 5mA / 500μA / 50μA a ni |
| Hnathawh dan lum leh vawt | 0–40℃a ni |
| Relative humidity a awm lo | 85% RH aia tlem emaw, a tlukpui emaw a ni |
| Hnathawh voltage a awm | DC 12–16.8V a ni a; AC 220V a ni |
| Power hmanralna a ni | 15W aia tlem emaw, a tlukpui emaw a ni |
| Dimension hrang hrang | 365 × 330 × 180 mm a zau a ni |
| Buk | 10 kg a ni |

Dilna hrang hrang
DC resistance test tih dan pangngai leh commissioning te chu:
- Power transformer hmanga siam a ni- winding do theihna; inter-turn short (reading hniam) emaw lead weld chhe / loose contact (high emaw open reading) emaw a ni thei.
- On-load tap changer te chu- tap position tinah contact resistance a awm
- Thil siam chhuahna QC- winding leh connection verification chu delivery hmain
- Generator te pawh a awm- stator leh rotor winding / lead chhunzawm zelna
- Switchgear, bus joint, cable, weld te pawh a awm bawk- hniam-resistance joint tehna
Accessory a ni
|
Serial Number a ni |
Hming |
Belhkhawm |
|
1 |
Mainframe a ni |
pakhat |
|
2 |
AC 220V Power line a ni |
pakhat |
|
3 |
Test line (8m) a ni. |
pakhat |
|
4 |
Ground-ah hmahruaitu a ni |
pakhat |
|
5 |
2A Fuse a ni |
pathum |
|
6 |
A sawifiahna |
pakhat |
|
7 |
Inspection Report neih a ni |
pakhat |
|
8 |
Certification pek a ni |
pakhat |

Prodect Qualification neih theihna tur

FAQ
Q1: DC resistance tester hian transformer ah eng nge a check thin?
Winding tin resistance a teh thin. Phase tehkhin hian harsatna a flag: reading hniam chuan inter-turn short a kawk a; reading sang emaw, open emaw chuan lead weld chhe, loose tap-changer contact, emaw connection chhe emaw a kawk a ni.
Q2: Engvangin nge winding lian tak hian chhiar nan hun a mamawh?
Windings hi inductive sang tak an ni - reading a stabilize hmain core chu magnetize a ngai a ni. Current tam zawk chuan a saturate rang zawk. He model top range hi 1A * a ni a; transformer lian tak tak tan chuan current model sang zawk-chu a settle rang zawk thei. Transformer capacity leh expected resistance min hrilh la, current dik tak kan match ang.
Q3: Engtiang chiahin nge a dik a, eng range nge a huam?
±(0.2% + 2 digit) across 1μΩ–20kΩ *, pali-wire Kelvin method, resolution 1μΩ * thlenga tlahniam.
Q4: Leads mid-test unclip hi a him em?
Awle. Automatic arc suppression hian test zawh hunah controlled path hmangin magnetic energy dahkhawm chu a discharge - disconnect hmain discharge zawh hun nghak rawh.
Q5: Mains power tel lovin field-ah ka hmang thei ang em?
Awle. Built-in battery plus AC 220V, ~10 kg *, bay inkar ah a leads neiin a kal thin.
Q6: Transformer tan chauh a ni em?
Range chhunga thil -resistance hniam tak tak - awm lo: generator, CT/PT winding, bus joint, cable, weld.
Q7: Eng warranty leh support nge i pek?
Unit-a warranty bakah dam chhunga technical support; i transformer size atana current rating dik tak (1A / 5A / 10A) i thlan theih nan kan pui che a ni.
Quote dil rawh
Test object, transformer chi leh rated capacity, resistance range beisei, leh site power supply te min rawn thawn rawh. Kan team hian current class dik tak chu a confirm a, darkar 24 chhungin spec sheet - quote chu a thawn chhuak thin.
hot tags .: 10a dc resistance tester, China 10a dc resistance tester siamtu, supplier, factory