Huayi: Professional Tan Delta Tester siamtute chuan an siam chhuak a.

 

A rilru a buai em em a, a rilru a hah em em bawk a. (Huayi for short) hi China rama professional manufacturer a ni a, electric testing hmanrua te zirchianna leh siamchhuah a ni. Huayi chuan mahni inrintawkna neia hmasawn leh hralh chhuah a tum tlat a, thil siam quality tihsan, sum senso tihtlem leh efficiency tihchangtlunna kawngah theihtawp a chhuah bawk.

 

 
 
Engvangin nge min thlan .

Thil tawn hausa tak .

Company hi kum 2005 khan din a ni a, kum sawm chuang zet professional experience a nei tawh a ni. China rama high-voltage testers siamtu hmasa ber zinga mi a ni.

Professional Technology hmanga tanpui theih a ni.

Kum 18 chuang zet testing leh solutions lama specialist a ni. Own engineer te pawh an awm. Professional on delivery, installation, debugging, leh training te.

ISO certification pek a ni.

Professional R&D technical team kan nei a, himna, dikna leh hman tangkai theihna tur quality control khauh tak kan nei bawk. pass ISO9001 certification pass a ni a, patent certificate kaihhnawih a dawng bawk.

Darkar 24 hnuah-Sales

Professional after-sales service, thil siam chungchanga customer-te ngaihdan ngaihven; darkar 24 chhunga solution pek, customer-te harsatna an neih chuan; Hmanhmawh tak leh tangkai takin hma la rawh.

 

Product Parameter 1000 a ni.

 

Hnathawh dan tur .

-15℃∽40℃a ni.

rh<80% a ni.

Anti-interference tih thupui hmanga thurin .

Frequency danglam thei .

Power supply a awm em?

AC 220V±10% a ni.

Generator phal a ni .

 

 

Output sang tak voltage .

0.5KV∽10KV(12KV siam theih a ni)

0.1KV apiangin .

Dik chiahna

2%

max current a ni.

200m a ni.

capacitance a awm em .

2000VA a ni tawh.

 

Mahni self-Power supply tha tak neih theihna tur .

 

AC 0V∽50V/15A a ni.

50Hz,60Hz Single Frequency,45Hz/55Hz,47.5Hz/52.5Hz,55Hz/65Hz,57.5Hz/62.5Hz,Automatic Frequency Automatic Converser a ni.

Thutlukna

TGΔ: 0.001% a ni.

CX: 0.001pf a ni.

 

Dik chiahna

△TGΔ:±(Chhiar*1.0%{{1}%) a ni.

△C x :±(reading*1.0%+1.00PF)

 

 

 

 

Test theihna hmun .

tgΔ .

Limitation a awm lo .

 

C x

15pf leh CX < 300nf a ni.

10kv a ni.

CX , 60 NF a ni.

5KV a ni.

CX , 150 NF 1000 a ni.

1KV a ni.

CX , 300 NF 1000 a ni.

CVT test a ni a.

CX , 300 NF 1000 a ni.

LCR test theihna hmun a ni.

L>20h(2KV) a ni.

R>10kΩ(2KV) a ni.

LCR test dikna .

1%

Angular resolution .

0.01

CVT Turn Ratio 1000 a ni.

10∽10000

CVT turn ratio dik tak a ni.

1%

CVT turn ratio resolution .

0.01

A lian zawng(host)(mm) .

350(L)×270(W)×270(H)

A lian zawng(accessory)(mm) .

350(L)×270(W)×160(H)

Memory theihna .

200 GB a support U disk data dahkhawmna .

A rih zawng(host) .

22.75kg a ni.

A rih zawng(accessory) .

5.25kg a ni.

 

 
Tan Delta Tester hlawkna .
 
01/

Enhanced equipment rintlakna .
Tan Delta Tester hian electrical equipment rintlakna nasa takin a tichak a ni. Insulation dinhmun a zir chian fo chuan maintenance team-te chuan an chak lohna awm thei chu an hlawhchham hmain an hmu thei a ni.

02/

Insulation hlawhchhamna hriat hmasak .
Tan Delta Tester hlawkna pawimawh tak pakhat chu an tir lamah insulation failure a hriat theihna hi a ni. Early detection hian a hun taka intervention a siam thei a, chhiatna rapthlak tak tak a thleng thei lo a, hnathawh chhunzawm zel a nih theih nan a veng thei bawk.

03/

Enkawlna senso tihtlem .
Tan Delta Tester kalpui hian enkawlnaah sum senso tam tak a humhim thei a ni. Hei hian downtime a tih tlem mai bakah electrical hmanrua te dam rei theihna a pui bawk a, chu chuan maintenance expense zawng zawng a tihhniam phah a ni.

04/

Portable leh hman awlsam .
Tunlai Tan Delta testers te hi a compact a, a rit lo a, user- field leh laboratory hmanna tur interface tha tak tak a awm bawk. Voltage level hrang hrang leh boruak dinhmun hrang hrangah tehna an ti thei a ni.

 

Transformer Tan Delta Tester

 

Tan Delta Tester hman dan tur .

Transformer insulation tehna: 1.1.Tan Delta Tester hi a bul berah chuan transformer insulation dinhmun tehna atan hman a ni a, insulation chak lohna emaw, chhiatna emaw awm thei te hriatchhuah a ni.

 

Diagnostic testing tih hi a ni.Tan delta value te hi hun kal zelah khaikhin chuan insulation chhe zel te chu hriat theih a ni a, a hun taka enkawl emaw siamthat emaw hun tur ruahman theih a ni bawk.

 

Quality control: 1.1.Transformer siamnaah hian insulation system quality leh integrity a awm theih nan Tan Delta testing neih thin a ni.

 

Electrical enkawl dan: 1.1.Routine check atan emaw, hmanraw thar commissioning lai emaw pawhin, Tan Delta Tester hi high-voltage system him taka kalpui chhunzawm zel theihna turin a pawimawh hle.

 

 

Ruangam

Power supply unit: 1.1.Insulation tehna atana test voltage mamawh a siam chhuak.
 

capacitor:Loss angle tehna dik tak leh calibration atana reference a pe.
 

Connection terminal:Insulation sample emaw hmanrua emaw inzawmna interface.
 

Voltage sensor te:Analysis atan electrical signal te hriatchhuah leh thawn chhuah.
 

Display module:User interface, touchscreen emaw buttons emaw, results atan display a awm bawk.
 

Hriselna kalphung: 1.1.Grounding, overvoltage, leh interlock protection hmanga him taka hnathawh a nih theih nan a enkawl.

50A Transformer DC Resistance Tester

 

Testing neih chhunga himna tur ruahmanna siam .

Tan Delta test neih chhung hian himna a pawimawh hle. Mahni leh hmanrua te humhim turin heng kaihhruainate hi zawm rawh:

Invenna hmanrua ha rawh .

Electrical hliam awm loh nan insulated gloves leh safety goggles hmang ang che.

01

Grounding mumal tak neih theih nan .

Electrical shock awm loh nan hmanrua chu ground tha tak a nih leh nih loh enfiah rawh.

02

Voltage level enkawl dan .

Insulation overload loh nan applied voltage chu en reng ang che.

03

Hmun him tak vawng reng rawh .

Test laiin hmanrua atanga hla takah ding la, hlauhawm awm thei tur laka invenna tur a awm thei ang.

04

Test environment 1000 a ni.

Test hi controlled environment-ah kalpui la, chu chuan pawn lam thil, result-a nghawng thei tur, humidity emaw temperature emaw ang chi chu a tih tlem theih nan.

05

 

Kan thawhpui dan tur .

 

 

Chhuifiahna:Online emaw zawhna min thawn emaw theih a ni. I thil mamawh kimchang chu a chiang thei ang bera pe rawh. Chuvangin a vawi khatnaah offer chu kan rawn thawn thei ang che.
Phone number: (+86)-18062012971/WhatsApp:+8618064115448
E-Mail: sales@sinohipot.com/ tina@sinohipot.com tih a ni.

 

Custom plan siam dan: 1.1.Consultation neih chhung hian i mamawh bikte kan evaluate ang a, kan thawhhona chuan i mamawh ang zela siam custom quality assurance plan kan siam ang.

 

Inremna leh Setup:Plan-a i lungawi tawh chuan a chipchiar zawngin kan finalise ang a, a bul tanna tur zawng zawng kan set up ang.

 

Quality assurance kalpui dan tur:Chumi hnuah chuan kan team chuan i thil siam emaw, i process emaw thlan chhuahah quality assurance protocols te chu an kalpui ang.

 

Sem:Tuipui hmanga emaw, a tul angin emaw cargos deliver.

 

Packaging leh delivery .

 

 

Packing detail:

Thing cases nen packing, shipping way solution hrang hrang pe rawh.

Pe:

Payment term tam tak kan pawm a, chu chu T/T, Western Union, L/C te an ni.

Warranty hun chhung:

Pakhat-kum warranty, install leh commissioning thil chi hrang hrang.

Delivery hun chhung:

Kan thil siam tam zawk hi stock a awm a, pawisa pek hunah pawh pek theih a ni. Delivery hun hi a tlangpuiin ni 15 aia tam a ni lo.

 

productcate-1-1

 

Kan certificate te .

 

productcate-1-1

 

FAQ a ni.

Q: Engtikah nge a man hi ka hmuh theih ang?

A: A tlangpuiin i zawhna kan hmuh hnu darkar 24 chhungin kan quote thin.

Q: I order quantity minimum chu eng nge ni, sample min thawn thei ang em?

A: Kan order quantity tlem ber chu 1 set a ni a, sample shipping fee hi nangmahin i pek a ngai a ni.

Q: A products te hi stock ah i nei em .

A: Kan tester tam zawk hian stock an nei a.Stock.

Q: A thawn chhuah hmain a thil siam test a awm em?

A: Kan thil siamte hian factory testing an nei a, report nen an inzawm bawk.

Q: Discount i nei dawn em ni?

A: Yes i order quantity a zirin discount hrang hrang kan pe thei. Kum tin promotional activities mumal tak kan nei bawk.

Q: I thil siamte chu export a ni tawh em?

A: Kum 10 chuang zet export lama tawnhriat kan nei tawh a. Local partner a awm leh awm loh confirm turin min rawn biak theih reng e.

Q: Transportation chungchang hi engtin nge ni ang?

A: A tlangpuiin kawngkhar to door》delivery kan la thin ,cause a awlsam zawk a, a rang zawk bawk.

Q: Tan Delta tester tih hi eng nge ni?

A: Tan Delta tester, dissipation factor emaw dielectric loss tester tia hriat bawk hi electrical hmanrua, transformer, cable, bushings, leh generator te insulation quality tehna hmanrua a ni. Dielectric loss angle (TAN Δ) tangent a tichiang a, hei hian insulation material-a heat anga energy hloh zat a tarlang a ni.

Q: Electrical test-naah hian "Tan Delta" tih hian eng nge a sawi tum?

A: "Tan Delta" (Tan Δ) chu insulating material-a resistive current (loss component) leh capacitive current (charging component) ratio a ni. Tan Δ value sang zawk chuan dielectric loss tam zawk leh insulation quality tha lo zawk a kawk a ni.

Q: Tan Delta Tester hi engzat nge i perform ang?

A: Kum tin hmanraw pawimawh tak tak i test thin tur a ni. System pawimawh lo zawk tan chuan kum hnih atanga kum thum danah test hi a tawk. Environment dinhmun leh hmanrua hman dan a zirin frequency siam that.

Q: Tan Delta testers hmangin eng hmanrua nge i test theih ang?

A: Tan Delta testers te hian transformer, cable, bushing leh generator te an thawk a. Kit thenkhat chu versatile an ni a, thenkhat erawh chu substation ang chi application bik atan an siam thung.

Q: Tan Delta value te hi engtin nge i hrilhfiah thin?

A: Test result hi industry standard emaw baseline value emaw nen khaikhin rawh. Reading pangngai chuan insulation hrisel tak a kawk a ni. Abnormal values ​​chuan moisture emaw contamination emaw ang chi issues, siamthat ngai tur a rawt a ni.

Q: Tan Delta Tester hi oil-eng hmanruaa hman atan hman theih a ni em?

A: Ni e, Tan Delta test hi oil-filled transformer leh bushings-a insulation condition tehna atan hman tlanglawn a ni a, chutah chuan oil chhunga tui awm emaw, bawlhhlawh emaw ang chi thil awmte hriatchhuahna kawngah a pui a ni.

Q: Tan Delta tehna hnuaia principle awm chu eng nge ni?

A: Tan Delta Tester hian insulation-ah AC voltage a apply a, specimen leh voltage leh current inkar phase angle hmangin current pahnih a teh vek a ni. Total current leh ideal capacitive current inkara phase angle danglamna tangent chuan tan Δ value a pe a.

China rama Tan Delta tester siamtu leh supplier professional ber pawl kan nih angin quality product leh competitive price te hian kan feature a ni. Kan factory atang hian China rama siam Tan Delta Tester man tlawm tak lei turin min lo hrilh la.

Inquiry thawn rawh .
Inquiry thawn rawh .