Huayi: Professional primary current injection tester siamtu a ni a, a man pawh a tlawm hle.

 

A rilru a buai em em a, a rilru a hah em em bawk a. (Huayi for short) hi China rama professional manufacturer a ni a, electric testing equipment zirchiang leh siamchhuah a ni. Huayi chuan mahni inrintawkna neia hmasawn leh hralh chhuah a tum tlat a, thil siam quality tihsan, sum senso tihtlem leh efficiency tihchangtlunna kawngah theihtawp a chhuah bawk.

 

 
 
Engvangin nge min thlan .

Thil tawn hausa tak .

Company hi kum 2005 khan din a ni a, kum sawm chuang zet professional experience a nei tawh a ni. China rama high-voltage testers siamtu hmasa ber zinga mi a ni.

Professional Technology hmanga tanpui theih a ni.

Kum 18 chuang zet testing leh solutions lama specialist a ni. Mahni engineer tawnhriat ngah tak tak an awm. Professional on delivery, installation, debugging, leh training te.

ISO certification pek a ni.

Professional R&D technical team kan nei a, himna, dikna leh hman tangkai theihna tur quality control khauh tak kan nei bawk. ISO9001 certification pass a ni a, patent certificate kaihhnawih a dawng bawk.

A hnu darkar 24 ah-Sales .

Professional after-sales service, thil siam chungchanga customer-te ngaihdan ngaihven; darkar 24 chhunga solution pek, customer-te harsatna an neih chuan; Hmanhmawh tak leh tangkai takin hma la rawh.

 

Product Parameter 1000 a ni.

 

Entawn tlak

A capacity (KVA) 1.1.

input .

Output 1000 a ni.

A zau zawng (mm)l×W×H .

Buk

(kg) a ni.

Thusawi .

voltage a ni a, a .

Tun

voltage a ni a, a .

Tun

SLQ-500 a ni.

3

220

15

6

500

430×338×550

48

productcate-1-1

SLQ-1000 a ni.

6

220

27

6

1000

500×380×600

80

Integrated structure 1.1.

SLQ-2000 a ni.

10

220

46

5

2000

600×430×790

130

Integrated structure 1.1.

SLQ- 2500 ah a awm.

15

380

39.5

6

2500

600×430×790

145

Integrated structure 1.1.

SLQ- 4000 ah a awm.

24

380

63

6

4000

640×450×820

180

Integrated / inthenna .

SLQ- 5000 ah a awm.

30

380

79

6

5000

600×430×900

300×500×500

145

135

A inzarpharh dan .

SLQ- 6000 ah a awm.

36

380

95

6

6000

600×430×900

300×500×500

150

140

A inzarpharh dan .

SLQ- 8000 ah a awm.

48

380

126

6

8000

600×450×950

350×550×550

180

A inzarpharh dan .

SLQ-10000 a ni.

60

380

158

6

10000

800×600×1100

380×550×600

200

A inzarpharh dan .

 

Video

 

 

 

 
Primary current injection tester a thatna te .
 
01/

Invenna hmanrua pe rawh .
Primary current injection tester hman thatna pawimawh tak pakhat chu protective devices performance chungchanga time data tak tak a pek theihna hi a ni. He feedback nghal hian technician-te chu hmanrua a chhiat emaw, himna atana hlauhawm emaw a thlen hmain thil awm thei tur awm thei apiang chu a hriat theih phah a ni.

02/

User-A design tha hle mai .
Primary current injection tester ah hian user-friendly design a awm a, electrical professional ten tester chu training tlem ber nen an operate thei tih a tichiang a ni. Digital display a awm a, awlsam taka enkawl theihna tur leh test scenario hrang hrang atana programm theih setting a awm bawk.

03/

Dik chiahna
Primary current injection testers te hi test mek hmanrua rintlak leh him leh him loh enfiah nan test result dik tak pek theih nan siam a ni. Electrical testing atana international standard leh regulations zawm tura ruahman an ni fo thin,test neihte chu rintlak leh inmil tura enkawl an ni.

04/

Portable a ni a .
Heng testers te hi field testing atan portable theih a ni a, lab emaw workshop setting-a hman tur stationary pawh a ni thei bawk. System thenkhat chuan data logging theihna an nei a, chu chuan test result chu analysis leh documentation atan a record thei a ni.

 

2000A Primary Current Injection test kit with triping time

 

Primary current injection tester leh secondary current injection tester inkar danglamna chu .

Primary leh secondary current injection testers te chu an approach leh scope ah an danglamna ber. Primary current injection test set set chuan fault-breaker-a rated current chu breaker kaltlangin multiple a inject a, trip time a teh a ni. Hetiang method hian breaker chu real-khawvel dinhmun a hnaih thei ang bera scenario-ah a test thin. A lehlamah chuan secondary current injection test kit chuan fault-prear chu trip unit-ah direct-in a inject a, breaker trip hun chhung a teh a ni. Hetiang method hian breaker system pumpui aiin trip unit-a timing leh function test a tum zawk a ni.

 

Primary current injection tester hman dan tur .
1

Power hman dan tur .

Protective relay leh circuit breaker test-na hmanga transmission leh distribution system rintlakna tur ngaihtuah. Entirnan, utility te hian heng testers te hi commissioning leh routine maintenance hun laiin an hmang a, chu chuan outage a awm loh nan a pui thin.

2

Industrial facility te .

Thil siamtu plant lian tak takte chuan heng testers-te hi an electrical protection scheme an finfiah theih nan an ring a, downtime an tih tlem bakah hmanrua an tihchhiat loh nan an hmang bawk.

3

Renewable Energy 1000 a ni.

Wind farm leh solar power plant te hian primary current injection tester hmangin an inverter leh transformer te protection system te chu an nemnghet a, hei hian him taka hnathawh a nih theih nan a pui a ni.

4

Data Center hrang hrangte .

Data center ang chi infrastructure pawimawh tak takte chu an electrical system-te test dik takah an innghat a, chu chuan uptime a vawng reng a, electrical fault avanga data hloh a awm loh nan a pui bawk.

 

 

Primary current injection tester a component hrang hrang te .

Typical components te chu:

  • High-Tunlai output transformer emaw amplifier emaw a ni.
  • control unit a ni.
  • Tuna tehna hman mek a ni.
  • Timer/Trip Detection Module a ni.
  • cooling system a ni.
  • Safety interlocks te pawh a awm thei.
5000A Primary Current Injection tester

 

Fimkhur tur .

 

Hman dan dik tak .

Tester chu uluk takin enkawl rawh. Vibration tam lutuk hnuaia dah emaw, dah emaw loh tur. Accident-a chhiatna thleng tur venna atana hman loh hunah venhimna hmunah dah tur a ni.

01

Environment dinhmun .

Temper hi temperature leh humidity range tarlan chhunga environment-ah hmang rawh. Extreme conditions hian hmanrua dik leh dam rei theihna a nghawng thei a ni.

02

Electrical a himna tur .

Tester hman hunah electrical safety protocol zawm fo ang che. Circuit breaker leh a kaihhnawih hmanrua te chu tester connect hmain de-energized a nih leh nih loh enfiah hmasa phawt ang che. Electrical hlauhawm lo tur ven nan mimal invenna hmanrua (PPE) remchang hmang ang che.

03

Training leh inhriatthiamna .

User zawng zawngte chu tester enkawl dan tur training tha tak an neih theih nan enfiah rawh. Hriselna atana hmanraw hman dan leh a tih theih chin hriat chian hi him leh tangkai taka hman theih nan a pawimawh hle.

04

Documentation 10 a awm.

Maintenance activities zawng zawng, calibration date zawng zawng, leh harsatna i tawh apiangte chu chipchiar takin ziak vek rawh. He documentation hian troubleshooting leh industry standards zawm a nih theih nan a pui thei a ni.

05

 

Kan thawhpui dan tur .

 

 

Chhuifiahna:Online emaw zawhna min thawn emaw theih a ni. I thil mamawh kimchang chu a chiang thei ang bera pe rawh. Chuvangin a vawi khatnaah offer chu kan rawn thawn thei ang che.
Phone number: (+86)-18062012971/WhatsApp:+8618064115448
E-Mail: sales@sinohipot.com/ tina@sinohipot.com tih a ni.

 

Custom plan siam dan: 1.1.Consultation neih chhung hian i mamawh bikte kan evaluate ang a, kan thawhhona chuan i mamawh ang zela siam custom quality assurance plan kan siam ang.

 

Inremna leh Setup:Plan-a i lungawi tawh chuan a chipchiar zawngin kan finalise ang a, a bul tanna tur zawng zawng kan set up ang.

 

Quality assurance kalpui dan tur:Chumi hnuah chuan kan team chuan i thil siam emaw, i process emaw thlan chhuahah quality assurance protocols te chu an kalpui ang.

 

Sem:Tuipuiah emaw, a tul angin thlawhna hmangin emaw cargos thawn chhuak thin ang che.

 

Packaging leh delivery .

 

 

Packing detail:

Thing cases nen packing, shipping way solution hrang hrang pe rawh.

Pe:

Payment term tam tak kan pawm a, chu chu T/T, Western Union, L/C te an ni.

Warranty hun chhung:

Pakhat-kum warranty, install leh commissioning thil chi hrang hrang.

Delivery hun chhung:

Kan thil siam tam zawk hi stock a awm a, pawisa pek hunah pawh pek theih a ni. Delivery hun hi a tlangpuiin ni 15 aia tam a ni lo.

 

productcate-1-1

 

Kan certificate te .

 

productcate-1-1

 

FAQ a ni.

Q: Engtikah nge a man hi ka hmuh theih ang?

A: A tlangpuiin i zawhna kan hmuh hnu darkar 24 chhungin kan quote thin.

Q: I order quantity minimum chu eng nge ni, sample min thawn thei ang em?

A: Kan order quantity tlem ber chu 1 set a ni a, sample shipping fee hi nangmahin i pek a ngai a ni.

Q: A products te hi stock ah i nei em .

A: Kan tester tam zawk hian stock an nei a.Stock.

Q: A thawn chhuah hmain a thil siam test a awm em?

A: Kan thil siamte hian factory testing an nei a, report nen an inzawm bawk.

Q: Discount i nei dawn em ni?

A: Yes i order quantity a zirin discount hrang hrang kan pe thei. Kum tin promotional activities mumal tak kan nei bawk.

Q: I thil siamte chu export a ni tawh em?

A: Kum 10 chuang zet export lama tawnhriat kan nei tawh a. Local partner a awm leh awm loh confirm turin min rawn biak theih reng e.

Q: Transportation chungchang hi engtin nge ni ang?

A: A tlangpuiin kawngkhar to door》delivery kan la thin ,cause a awlsam zawk a, a rang zawk bawk.

Q: Primary current injection testing hian molded case circuit breaker a tichhia thei em?

A: Test hi dik taka kalpui a nih loh chuan molded case circuit breakers (MCCBS) chu primary injection test hmangin a chhiat theih a ni. Primary injection test hian circuit breaker chhunga thil awmte chu stress leh chhiatna a thlen thei a ni. MCCBs tihchhiat loh nan test current chu equipment-a rated current range chhunga awm a nih theih nan leh circuit breaker testing eng pawh controlled condition hnuaia tih a nih theih nan a pawimawh hle.

Q: Primary current injection tester tih hi eng nge ni?

A: Primary current injection tester hi high-voltage electrical equipment hnathawh leh himna finfiah nana hman thin electrical engineering process pawimawh tak a ni. He testing method hian equipment circuit-a controlled current inject a, engineer-te’n load condition hrang hrang hnuaia hmanrua an thawh dan an zirchian theihna tur a ni.

Q: Primary current injection tester hian engtin nge hna a thawh?

A: Power source atanga controlled high current siamin primary circuit-ah a feed lut a, a thawk a ni. Tester hian test trip hnuaia device chu a hun bituk chhunga a awm leh awm loh a enfiah theih nan current leh time pahnih a enfiah thin.

Q: Test procedure pangngai chu eng nge ni?

A: Tester chu primary circuit-ah connect rawh.
Current level duh chu set rawh.
circuit chu zawi zawiin energize rawh.
Trip current leh hun tehna tur.
A result chu record rawh.
de-Energize la, him takin disconnect rawh.

Q: Engvangin nge primary injection test-naah hian high current a mamawh?

A: A chhan chu a tum ber chu fault dinhmun tak tak simulate a nih avangin, chu chuan current flow sang tak a huam a ni. Hei hian protective devices te chu actual fault condition hnuaiah an thawk dik em tih a nemnghet a ni.

China rama primary current injection tester siamtu leh supplier professional ber pawl kan nih angin quality product leh competitive price te hian kan feature a ni. Kan factory atang hian hetah hian China rama siam primary current injection tester man tlawm tak lei turin inrintawkna nei la.

Inquiry thawn rawh .
Inquiry thawn rawh .