Huayi: Professional VLF Hipot Tester siamtute chuan an siam chhuak a.
A rilru a buai em em a, a rilru a hah em em bawk a. (Huayi for short) hi China rama professional manufacturer a ni a, electric testing equipment zirchiang leh siamchhuah a ni. Huayi chuan mahni inrintawkna neia hmasawn leh hralh chhuah a tum tlat a, thil siam quality tihsan, sum senso tihtlem leh efficiency tihchangtlunna kawngah theihtawp a chhuah bawk.
-
VLF Hipot leh Tan Delta Test te a awm a.Model number: HYCDP-R. 1. Multi-Cable test hman zawh.. 2.Dielectric hloh, capacitance, leh insulation te test theih a ni.. 3.Small in size, a rit zawnga rit, hman awlsam.View More
-
0.1Hz VLF 90KV hipot tester a ni a, a changtute pawh an t...A rilru a buai em em a, a rilru a hah em em bawk a. Test range lian tak: 0.1Hz, 0.05Hz leh 0.02Hz multi-frequency thlan theih a ni.. 2. Hriselna leh rintlakna.. 3. Electrical hmanrua insulation tlukpui capacitance (power cable, powerView More
-
VLF 80KV hipot tester a ni a.Model: HYCDP-V. 1. VLF Hipot Tester hian test range lian tak a nei a, chungte chu 0.1Hz, 0.05Hz, leh 0.02Hz multi-frequency selection a ni.. 2. Volume tlem leh rit lo: pawn lama hnathawh nan a awlsam hle.. 3. output nghet leh performanceView More
-
VLF AC Hipot Tester a niMode number: HYCDP-H VLF AC Hipot Tester tih a ni. 1. A chhuahna frequency: 0.1,0.05, leh 0.02 Hz.. 2. Generator lian tak tak, cable, leh thil dangte a test thei a;. 3. Capacity resonant transformer a thlak thei..View More
-
Frequency hniam tak Hipot Test Kit a niUltra-low frequency insulation withstand voltage test hi a takah chuan power frequency withstand voltage test ai chuan a danglamna a ni. Generator lian tak tak, cable leh power frequency voltage test atana test product dangte tan chuanView More
-
VLF cable test nana hmanrua te .Ultra-Low frequency insulation withstand voltage test hi a takah chuan power frequency ai chuan voltage test a ni. Generator lian tak tak, cable leh test product dang power frequency voltage test atan chuan capacity lian tak tak resonantView More
Engvangin nge min thlan .
Thil tawn hausa tak .
Company hi kum 2005 khan din a ni a, kum sawm chuang zet professional experience a nei tawh a ni. China rama high-voltage testers siamtu hmasa ber zinga mi a ni.
Professional Technology hmanga tanpui theih a ni.
Kum 18 chuang zet testing leh solutions lama specialist a ni. Mahni engineer tawnhriat ngah tak tak an awm. Professional on delivery, installation, debugging, leh training te.
ISO certification pek a ni.
Professional R&D technical team kan nei a, himna, dikna leh hman tangkai theihna tur quality control khauh tak kan nei bawk. pass ISO9001 certification pass a ni a, patent certificate kaihhnawih a dawng bawk.
A hnu darkar 24 ah-Sales .
Professional after-sales service, thil siam chungchanga customer-te ngaihdan ngaihven; darkar 24 chhunga solution pek, customer-te harsatna an neih chuan; Hmanhmawh tak leh tangkai takin hma la rawh.
Product Parameter 1000 a ni.
|
Entawn tlak |
Rated voltage 1000 a ni. |
Load theihna . |
Power fuse a awm em? |
Reference rit zawng . |
|
VLF-30 (30KV) a ni. |
30KV/20mA a ni. (Peak hlutna) . |
0.1Hz, 0.5μF~1.1μf aia tlem emaw a aia tlem emaw |
5A |
Controller:4kg a ni. Booster:25kg a ni. |
|
0.05Hz, 0.5μF~2.2μF aia tlem emaw a aia tlem emaw |
||||
|
0.02Hz, 0.5μF~5.5μF aia tlem emaw a aia tlem emaw |
||||
|
VLF-50 (50KV) a ni. |
50KV/30mA a ni. (Peak hlutna) . |
0.1Hz, 0.5μF~1.1μf aia tlem emaw a aia tlem emaw |
7A |
Controller:4kg a ni. Booster:50kg a ni. |
|
0.05Hz, 0.5μF~2.2μF aia tlem emaw a aia tlem emaw |
||||
|
0.02Hz, 0.5μF~5.5μF aia tlem emaw a aia tlem emaw |
||||
|
VLF-60 (60KV) a ni. |
60KV/30mA a ni. (Peak hlutna) . |
0.1Hz, 0.5μF aia tlem emaw a aia tlem emaw |
9A |
Controller:4kg a ni. Booster 1(30kV):25kg a ni. Booster 2(30kV):25kg a ni. |
|
0.05Hz, 0.5μF~1μF aia tlem emaw a tlukpui emaw a ni. |
||||
|
0.02Hz, 0.5μF~2.5μF aia tlem emaw a aia tlem emaw |
||||
|
VLF-80 (80KV) a ni. |
80KV/30mA a ni. (Peak hlutna) . |
0.1Hz, 0.5μF aia tlem emaw a aia tlem emaw |
12A |
Controller:4kg a ni. Booster 1(30kV):25kg a ni. Booster 2(50kV):50kg a ni. |
|
0.05Hz, 0.5μF~1μF aia tlem emaw a tlukpui emaw a ni. |
||||
|
0.02Hz, 0.5μF~2.5μF aia tlem emaw a aia tlem emaw |
Video
VLF Hipot Tester-a ṭhatnate chu a hlawhtling hle.
Hriselna tihchangtlun:VLF hipot tester hman hian test object chhunga current luang zat chu nasa takin a tlahniam a. Hetianga current tihtlem hian insulation tihchhiat theihna leh operator-te hnena electrical shock theihna a tihtlem phah a ni.
Insulation defects te hriat hmasak dan:VLF hipot tester hman avanga long - thumal hman tam ber pakhat chu a tir lama insulation defects a hriat theihna hi a ni. Hei hian downtime man to tak a veng mai bakah electrical hmanrua te dam chhung a ti rei bawk.
Cost - A hlawhtlinna:VLF hipot testers te hi traditional high - frequency testers te nen khaikhin chuan energy - an hmang tangkai zawk a ni. Frequency hniam takah an thawh avangin testing process chhungin power an hmang tlem zawk thin. Hun a kal zel a, hei hian electric bill-a sum tam tak a humhim thei a ni.
Portability: 1.1.VLF Hipot testers te portability hian ON - site testing a phalsak a, hei hian hmanraw rit leh bulky tak tak testing facility-a phurh luh a ngai tawh lo.
Thil hmanrua hnathawh that zawk:VLF Hipot Tester hmanga test fo hian electrical hmanrua zawng zawng a ti tha thei a ni. Insulation defects te chu a hmaa hmuhchhuah leh siamthat a nih chuan electrical equipment te chu a thawk tha zawk thei a ni.
VLF Hipot Tester hman dan tur .
Utility leh power siam chhuah dan .
Power plant leh utility company te chuan cable hmangin voltage lian tak takah electric an thawn chhuak thin. VLF Hipot testers te hian heng cable sei tak takte hian load hi him takin an buaipui tih an nemnghet a ni. Harsatna a lo awm hmaa test neih fo hian power tlakchhamna nasa tak a thlen loh nan a pui a ni.
01
Thil siamchhuahna hmun .
Assembly plant leh factory lian dangte chuan internal electrical system atan cable an siam thin. VLF hipot testers te hian heng cable sei tak tak te hi an enfiah a, production machine te hian an mamawh power an neih theih nan an enfiah thin. Wiring-a harsatna eng pawh man chuan machine-te chu an thawk chhuak thei a, chu chuan output level a ti sang zawk a ni.
02
Transportation kalphung .
Subway, rel, leh bus thenkhatah chuan electric cable hmanga system pumpui power pek theihna an hmang a ni. VLF hipot testers te chuan heng cable te hi an enfiah a, rel te chu him tak leh a hun taka an tlan theih nan an enfiah thin. Hei hian passenger-te tan tihkhawtlai a awm loh nan a pui a, khar pawh a titawp thei bawk.
03
lawng leh aerospace .
Advanced electronics chu lawng lian tak tak, lawng leh thlawhna chhungah te hmuh tur a awm a. VLF hipot testers te chuan cable sei tak tak te hian thlipui emaw, hmun sang tak emaw ang chi dinhmun khirh tak tak an tuar thei tih an nemnghet. Flight emaw zin emaw hmaa cable test hian internal system zawng zawng a ti tha vek a ni.
04
Data Center hrang hrangte .
Big data center-ah hian computer leh server-te tichaktu cable sang tam tak a awm a. VLF Hipot Testers te chuan heng cable te hian engkim online a awm reng theih nan electric mamawh chu an handle thei em tih an enfiah thin. Wiring hmasa lama harsatna awmte man hian downtime a veng thei a, hei hian a man a to thei hle.
05
VLF hipot testers te chuan cable emaw hmanrua emaw ah hian low-frequency AC voltage (a tlangpuiin 0.1 Hz atanga 0.1 kHz inkar ah) an hmang thin. VLF hman thatna chu frequency sang zawk emaw DC testing nena khaikhin chuan power consumption leh heating effects tlem zawk nei cable sei leh system lian tak tak test theihna a ni.
DC hipot testers te chuan cable emaw hmanrua emaw ah DC voltage sang tak (a tlangpuiin 5 kV atanga 100 kV emaw a aia tam emaw) an hmang thin. Test hian insulation chu high-voltage DC potential hmangin a stress a, chu chuan a chhe ber-case scenario a simulate a, high voltage condition hnuaia insulation chak lohna emaw breakdown emaw hriat theihna atan hman a ni.

Hman dan tur .

Test area chu tifai la, vawt rawh:Test neihna tur hmun chu a faiin a vawt em tih enfiah tur a ni. Tui ding emaw, thil hnim emaw awm apiang chu paih chhuak rawh.
Tester chu enfiah rawh:VLF Hipot Tester chu a chhiat emaw, a hnim emaw a awm leh awm loh enfiah rawh. Cables, connector, leh electrode te chu corrosion emaw thil dang emaw a awm leh awm loh enfiah thin ang che.
Test parameter dik tak thlang rawh:High - humidity condition-ah chuan test parameters te chu i siamrem a ngai mai thei. Mahse, test object-a rated voltage aia tam lo turin fimkhur rawh.
Grounding dik tak:VLF Hipot Tester chu a ground tha em tih enfiah tur a ni. Ground connection tha tak chuan stray current eng pawh a ti bo thei a, electric shock hlauhawmna a ti tlem bawk.
Leakage current a awm leh awm loh enfiah thin ang che:Leakage current readings te chu en reng ang che. Leakage current nasa taka a punna i hmuh chuan humidity sang tak avanga lei chung a leak tih chhinchhiahna a ni thei.
Tester chu tihfai la, uluk takin dah rawh:VLF hipot tester chu tifai la, a tui emaw, a bawlhhlawh emaw a awm chuan a chhuak thei ang. Hmun vawt takah dah hmain uluk takin vawt rawh. Tester chunglam chu puan nem leh vawt tak hmangin i phihfai thei bawk.
Kan thawhpui dan tur .
Chhuifiahna:Online emaw zawhna min thawn emaw theih a ni. I thil mamawh kimchang chu a chiang thei ang bera pe rawh. Chuvangin a vawi khatnaah offer chu kan rawn thawn thei che a ni.
Phone number: (+86)-18062012971/WhatsApp:+8618064115448
E-Mail: sales@sinohipot.com/ tina@sinohipot.com tih a ni.
Custom plan siam dan: 1.1.Consultation neih chhung hian i mamawh bikte kan evaluate ang a, kan thawhhona chuan i mamawh ang zela siam custom quality assurance plan kan siam ang.
Inremna leh Setup:Plan-a i lungawi tawh chuan a chipchiar zawngin kan finalise ang a, a bul tanna tur zawng zawng kan set up ang.
Quality assurance kalpui dan tur:Chumi hnuah chuan kan team chuan i thil siam emaw, i process emaw thlan chhuahah quality assurance protocols te chu an kalpui ang.
Sem:Tuipuiah emaw, a tul angin thlawhna hmangin emaw cargos thawn chhuak thin ang che.
Packaging leh delivery .
|
Packing detail: |
Thing cases nen packing, shipping way solution hrang hrang pe rawh. |
|
Pe: |
Payment term tam tak kan pawm a, chu chu T/T, Western Union, L/C te an ni. |
|
Warranty hun chhung: |
Pakhat-kum warranty, install leh commissioning thil chi hrang hrang. |
|
Delivery hun chhung: |
Kan thil siam tam zawk hi stock a awm a, pawisa pek hunah pawh pek theih a ni. Delivery hun hi a tlangpuiin ni 15 aia tam a ni lo. |

Kan certificate te .

China rama VLF Hipot Tester siamtu leh supplier professional ber pawl kan nih angin quality product leh competitive price te hian kan feature a ni. Kan factory atang hian China rama siam VLF Hipot Tester man tlawm tak lei turin inrintawkna nei rawh.
