SinoHipot hian high voltage testing hmanrua leh solution siamtu, lab, utilities, leh field service team te tan a supply thin a ni. AC/DC withstand voltage testing, VLF testing, resonant test system, HV tehna, leh specialized application dangte kan huam a ni.
I test object bik atana setup dik tak zawng turin a hnuaia category te hi browse la.
-
DC hipot generator tester a ni a, a man pawh a to hle.Model number: ZGS-120KV. 1. Voltage-doulbing electric circuit frequency sang tak nei a hmang.. 2. Voltage a stable a, ripple pawh a tlem.. 3. High-Thil chiang tak 0.75u1ma hnathawh dan button.. 4. Customization thlawp rawh..View More
-
1000KVA 500KV PD-A thlawna Variable Frequency Series Reso...Model number: HYWJF-1000KVA 500KV a ni. 1. PD-Free Variable Frequency Series Resonant leh induction test atan a tha.. 2. Test frequency 30-300Hz thleng a ni.. 3. PD value 10pC aia tlemView More
-
13860kVA 350kV AC Resonant Test System Cable Test leh GIS...Model number: XZB-13860KVA 350KV AC resonant test system hmanga siam a ni. 1. 220kV leh a hnuai lam GIS/switchgear AC hipot test atan a tha.. 2. Test frequency 30-300Hz thleng a ni.. 3. Test voltage 325kV aia tam lo, test hun 1min.View More
-
GIS Testing atan 500KV 1500KVA AC Resonant Test System a niModel number: XZB-1500KVA 500KV AC resonant test system hmanga siam a ni. 1. 220kV leh a hnuai lam GIS/switchgear AC hipot test atan a tha.. 2. Test frequency 30-300Hz thleng a ni.. 3. Test voltage 490kV aia tam lo, test hun 1min.View More
-
300kV PD-free Power Frequency AC Hipot Test Set a niModel: HYJF-300KVA 300KV hmanga siam a ni. Hming: PD free Power frequency AC hipot test system a ni. Partial discharge level: Rated voltage-ah 5 pC aia tlem emaw a tlukpui emaw, 80% rated voltage-ah 3 pC aia tlem emaw a tlukpui emawView More
-
4-channels 3-phase power quality analyzer a ni.Model number:SMG7000B 3-phase power quality analyzer a ni a, a man pawh a tlawm hle.View More
-
A rilru a buai em em a, a rilru a hah em em bawk a.Model: YDJ-350KVA 350KV Test voltage 350kVTest Frequency:50HzTest Current: 1AView More
-
240kV cascade test transformer system a ni.Product Introduction Test transformer voltage sang zawk nei tur chuan voltage sang zawk neih theih nan cascade method pawh hman theih a ni bawk. Figure 2-ah hian pathum-stage series test transformer-a principle wiring diagram tarlan a ni.View More
-
Multi-Frequency induction hian voltage tester a tuar thei...1. HYDBF hi single-piece, lightweight, easy-to-Field hmang thei a ni.. 2. Working mode pahnih a nei a, automatic leh manual a nei a, hei hi field situation a zirin flexibly thlan theihna a ni.. 3. DSP Platform Technology hman a ni..View More
-
600kV High Voltage (HV) Testing AC Resonant Test System o...Model Number: XZB-3200KVA 600KV AC Resonant Test System hmanga siam a ni.. 1. 400kV tan a tha a, GIS/Switchgear AC Hipot test hnuaiah a tha bawk.. 2. Test frequency 30-300Hz.. 3. Test voltage 595kV aia tam lo, test hun 1min.View More
-
1200KVA 600KV AC Resonance Test system chu 400KV GIS Test...AC resonant test system hi 400kV leh GIS/Switchgear AC hipot test hnuai lam tan a tha a, test frequency 30-300Hz, test voltage 520kV aia tam lo, test time 1min.View More
-
300KVA/300KV a awm a, a hlawhtlinna chu a hlawhtlinna a ni.Model: XZB-300KVA 300KV AC Resonant Test System.AC resonant test system hi 132kV leh a hnuai lam GIS/Switchgear AC hipot test, test frequency 30-300Hz, test voltage 300kV aia tam lo, test hun 1min a ni.View More
High Voltage Testing hmanrua chi hrang hrang
DC hipot tester te hian cable, transformer, arresters, switchgear, leh power equipment dangteah direct-current withstand voltage testing leh leakage current tehna an ti thin. Output voltage, current rating, leakage measurement range, leh standard hman tur te hmangin model thlan tur a ni.
AC hipot tester hi electrical hmanrua leh insulation system-a AC withstand voltage testing atana siam a ni. Test configuration dik tak chu rated voltage, insulation characteristics, test object, leh test mamawh tur hman danah a innghat a ni.
Frequency hniam tak (VLF) hipot tester hian application thlan bikte tan power-frequency AC testing ai chuan a dang a pe a, a bik takin medium-voltage cable testing procedure thenkhatah. A remchan dan chu cable chi hrang hrang, standard hman tur leh test dan mamawh danah a innghat a ni.
Resonance test system hi capacitive load tling tak tak high-voltage AC testing atan hman a ni. Resonant circuit hmang hian system hian test object electrical characteristics atana configuration thlan chhuah hmangin high-voltage testing mamawh bik a tlin thei a ni.
System thlannaah hian test voltage mamawh, capacitance, test frequency leh operating condition dangte ngaihtuah tur a ni.
High Voltage tehna leh a kaihhnawih Testing hmanrua te
High voltage divider hi high voltage chu level hniam zawka scale nan hman a ni a, chu chu tehna hmanrua inmil hmanga teh theih a ni. Divider mamawh chu voltage range, AC emaw DC emaw tehna mamawh, dikna leh tehna system-ah a innghat a ni.
Primary current injection tester hi electrical installation leh venhimna hmanrua te current sang-crient test nan hman a ni a, a tulna hmunah chuan circuit breaker, current transformer, leh protective relay system te pawh a tel a ni.
Hipot tester ang lo takin heng instrument te hian current injection leh electrical functions kaihhnawih verification te hi an ngaih pawimawh ber a ni. Output current mamawh, duration, leh test configuration te chu test object leh procedure atanga teh tur a ni.
Electrical insulating appliances-ah hian hmanraw chi leh himna tehfung hman tur nena inmil test neih a ngai a ni. Test dan, voltage leh acceptance criteria te hi insulating product leh a hman tum dan azirin a inang lo.
High Voltage Testing hmanga thil tih dan tur
AC Hipot Testing System hrang hrang a awm bawk
AC hipot test-naah hian instrument pakhat aia tam a ngai fo thin. System configuration hi test object, voltage level, load characteristic leh site condition ah a innghat a ni.
GIS Partial Discharge leh Hipot Testing neih a ni bawk
GIS testing hian a tlangpuiin withstand voltage testing leh partial discharge assessment te a huam vek a ni. System thlan dan hi GIS design, test kalphung, leh project mamawh danah a innghat a ni.

Measurement mamawh: 1.1.Test atana voltage, current, emaw partial discharge tehna mamawh te hriatchhuah.
Hnathawhna hmun: 1.1.Thil hmanrua chu laboratory, thil siamna hmun, field-testing environment-ah hman a ni dawn em tih chiang takin sawi rawh.
I application nena inmil category i hriat chian loh chuan kan team biak hunah test object, test voltage mamawh, applicable standard, leh intended use environment te pe rawh.
High Voltage Testing Equipment dik tak thlan dan
Tester emaw test system kimchang emaw i thlan hmain a hnuaia thilte hi ngaihtuah hmasa phawt ang che:
Test thil: 1.1.Test tur hmanrua, cable, transformer, switchgear, GIS, emaw insulating appliances te chu hriatchhuah tir rawh.
Test dan: 1.1.Procedure mamawh chuan AC, DC, VLF, resonant testing, current injection, emaw method dang emaw a tarlang em tih finfiah rawh.
Voltage leh current mamawh zat:Test voltage mamawh, output current, leh test hun chhung chu a hman dan tur angin ruat rawh.
Load ziarang hrang hrang:Test object electrical characteristics ngaihtuah la, a bik takin resonant test system evaluate hunah.
Measurement mamawh: 1.1.Test atana voltage, current, emaw partial discharge tehna mamawh te hriatchhuah.
Hnathawhna hmun: 1.1.Thil hmanrua chu laboratory, thil siamna hmun, field-testing environment-ah hman a ni dawn em tih chiang takin sawi rawh.
I application nena inmil category i hriat chian loh chuan test object, test voltage mamawh, applicable standard, leh intended use environment engtikah ngekan team te biak pawh theih a ni.
Operation Video hmanga tih a ni
Production Line siamna tur a ni

Kan Thawhho Dan
Product, service, technology chungchangah zawhna i neih chuan min rawn biak theih reng e. Kan awm reng ang a, i mamawh kan ngaithla reng ang.
Kan address
China ram Wuhan khawpuiah Gaoxin 4th Road, No.40-ah a awm a
Phone Number a ni
(+86)-18062012971
whatsapp:+8618064115448 tih a ni.
E-mail hmanga thawn a ni
Packaging leh Delivery te pawh a awm bawk
|
Packing chungchang chipchiar takin: |
Thing case nen packing, shipping way solution hrang hrang pe rawh. |
|
Pe: |
Payment term tam tak kan pawm a, chu chu T/T, Western Union, L/C te hi a ni. |
|
Warranty hun chhung: |
Kum khat- warranty, Installation, leh thil chi hrang hrang commissioning. |
|
Delivery hun chhung: |
Kan thil siam tam zawk hi stock-ah a awm a, pawisa pek veleh kan rawn thawn thei bawk. Delivery hun hi ni 15 aia rei lo a ni tlangpui. |

Kan Certificate te hi

FAQ
Q: AC leh DC hipot testing hi eng nge a danglamna?
A: AC hipot testing hian insulation-a operating stress tak tak simulate turin alternating voltage a hmang a, DC hipot testing hian steady direct voltage hmangin leakage current tehna atan minimal capacitive charging a hmang thung. AC testing hi a tlangpuiin AC power hmanga kal hmanrua tan chuan a aiawh zawk a ni a; DC testing hi high-capacitance object cable sei tak tak tan chuan duhthusam a ni fo a, chutah chuan test power a mamawh tlem zawk a, leakage reading chiang zawk a pe bawk. Standard hman danin a phal loh chuan method pahnih hi inthlak danglam theih a ni lo.
Q: Engtikah nge VLF hipot tester hi ka ngaihtuah ang?
A: VLF hipot tester hi medium-voltage cable testing atan ngaihtuah a ni tlangpui a, a bik takin a kalphung chuan power-frequency AC emaw DC emaw ai chuan frequency hniam tak AC phalsak a nih chuan. Commissioning leh preventive maintenance neih laiin XLPE leh solid-insulation cable dangte tan hman a ni tlangpui a, a chhan chu cable sei tak tak chu portable setup nei zawkin a test thei a, DC-related insulation stress risk a tlem zawk bawk. VLF unit thlan hmain cable type, test standard, leh acceptance criteria te chu confirm hmasa phawt ang che.
Q: Engtin nge test voltage mamawh chu ka thlan theih ang?
A: Test voltage chu standard hman tur, equipment rating, insulation type, leh test procedure atanga lo chhuak tur a ni—tester output sang ber atanga lo chhuak tur a ni lo. Voltage hniam-voltage product thenkhat tan chuan rule of thumb hman tlanglawn tak chu 2 × working voltage + 1,000 V a ni a, mahse hei hi khawvel pumah hman a ni lo. Power hmanrua atan chuan AC, DC, emaw VLF test value tarlan angin zawm la, hmanrua thlan bik ah voltage margin tling tak dah rawh.
Q: Testing system kimchang emaw, individual instrument emaw ka mamawh em?
A: Test object leh site mamawh danah a innghat. Tester pakhat chauh hi withstand emaw leakage check awlsam tak atan a tawk thei a, test lian zawk emaw, complex zawk emaw—cable, GIS, transformer, emaw partial-discharge testing ang chi te erawh chuan control unit, HV source, divider, measuring device, leh protection accessories te a mamawh thei thung. Test standard, voltage level, load capacitance, leh hna chu lab-ah emaw field-ah emaw tih a nih leh nih loh te chu thutlukna siam hmain sawifiah hmasa phawt ang che.
China rama high voltage tester siamtu leh supplier professional ber pawl kan nih angin, quality product leh competitive price-in kan rawn pholang a ni. Kan factory atang hian hetah hian China rama siam high voltage tester man tlawm zawk lei turin inring reng ang che.
