RBX-H Sweep Frequency Response Analyzer(FRA Test)

Mar 12, 2020

Message pakhat dah la .

Grid transmission system-a hmanraw pawimawh ber chu transformer a ni. Chuvangin, transformer him taka hman hian grid safety-ah hmun pawimawh tak a chang a ni. Huayi Power-a Technical Engineer-te chuan transformer winding deformation awm chhan leh a rah chhuah hlauhawmte chu transformer-te common fault winding deformation an zirchianna hmangin an zirchiang a ni. Grid security system pumpui hnathawh dan pangngai atan chuan a pawimawh hle.

 

Kan engineer-te chuan transformer chu short-circuit current emaw, impact dang emaw a nih chuan deformation chu hetiang hi a ni ang tih an rawt a.

Winding deformation hi pawn lam thiltihtheihna, transportation laiin impact, inclination leh vibration te avanga lo awm a ni a, chu chuan winding displacement a thlen thin. He deformed winding hian size inang a nei a, mahse core-a relative displacement chauh a danglam thung. Winding inductance, inter-cake capacitance chu a awm reng a, capacitance pawh a danglam bawk. General capacitance a tlahniam a. Equivalent circuit-ah chuan resonance peak chu high frequency lam hawiin a inthlak a. Chuvangin spectrum hlui nena khaikhin chuan resonance point tin hi measured spectrum-ah a la awm reng a, danglamna a awm lo va, mahse peaks chu high frequency (dinglamah) lamah a inthlak a ni.

 

Cake inkara partial deformation, unfixed thread cake thenkhat chu short-circuit electromagnetic force action hnuaiah squeeze a ni a, a dangte chu elongated a ni a, (power pole pahnih nen direct-in, leh electrical appliances-ah current awm lo) cake inkar capacitance chu a danglam thei a ni. Deformation hian equivalent circuit-a inductance thenkhat chu a lian zawk a, thenkhat chu a te zawk a; Inductance nena inmil cake inkara capacitance pawh a danglam bawk. Spectrum tehnaah chuan resonance peak thenkhat chu high frequency lam panin an kal a, peak value chu a tlahniam a; Resonance point thenkhat chu low frequency lam panin a kal a, peak point chu a sang chho ta a ni. Cake inkar deformation area leh deformation℃chu resonance peak inthlak danglamna hmangin an teh thin.

 

Turn inkar short circuit (power pole pahnih nen direct-a inzawm, leh electrical appliances-a current awm lo)), theoretically, turn inkar short circuit a thlen hnuah inductance value a tlahniam a, spectrum curve a inthlak nasa a, amplitude a sang a, resonance point peak thenkhat a bo bawk. Mahse hei hi theory a ni a, a nihna takah chuan hmuh a harsa hle. Operation laiin inter-turn short circuit a lo awm chuan coil chu a kang chhuak ang a, gas rit tak chu a trip ang a, pressure relief valve chu a start ang. Hetih lai hian transformer (pressure variation) oil chromatography chu a tling lo ang a, transformer pawh a check ang.

 

Lead’s displacement leh deformation, a chhan chu lead hi a sei em em a, a nghet taka a awm loh chuan a hnathawh laiin displacement deformation a awm thin. Lead a displace chuan pahnih-port capacitance chu equivalent circuit-ah a inthlak ang. Signal luhna hmuna signal chu a inthlak a, mahse lead capacitance chu circuit dang nen a inmil a, chuvangin a chan0 hian spectral curve-ah nasa takin nghawng a nei lo. Mahse, output lead displacement a awm a, lead capacitance inthlak danglamna hian frequency response curve nasa takin a thlak danglam dawn a, a bik takin 300 kHz atanga 1 MHz curve inkar a ni. Chuvangin, test tak takah chuan source chu a chunga effects te ven nan neutral point inject a ni. Lead-to-ground capacitance a tlahniam chuan frequency band-a amplitude a sang a, a lehlamah pawh a ni. Lead-to-ground capacitance a lian zawk chuan lead chu shell lam hawiin a kal tih a tilang a, lead-ground capacitance chu a te zawk tih a tilang a, chu chuan lead chu winding lam pan turin a kal tih a tilang a ni.

 

Winding chu radial deformation a hmu a, winding chu radial force a nih chuan inner winding chu chhung lamah a inzawm a, diameter leh inductance te chu a te zawk a ni. Hetih lai hian inner leh outer windings inkar hlat zawng chu a lian zawk a, capacitance chu a te zawk a, chu chuan spectrum chhunga resonance peak point chu high frequency lam pan turin a siam ang a, amplitude a tisang ang.

 

A winding twists leh a deforms te chu axially. Transformer inkar coil space (pressure variation) a lian emaw, a then chu a inthlak danglam emaw a nih chuan, electromagnetic force hnathawh nen chuan winding chu axially-in s shape-ah an twist a. Hetih lai hian cake capacitance leh ground capacitance thenkhat chu a tlem hle. Measured spectrum-ah chuan resonance peak thenkhat chu high frequency direction lam panin an kal a, resonance peak amplitude chu low frequency range-ah a tlahniam a, middle frequency-a peak chu a sang deuh a, high frequency range chu a danglam lo.

 

Base on the measurement of internal winding characteristic parameters of transformer, huayi power developed rbx-H transformer winding deformation tester, leh ram changkang zawka chhui chhuah internal fault frequency response analysis (FRA) method a hmang a, chu chuan transformer chhungril lama fault-ah rorelna dik tak a siam thei a ni. Device chu transfer-te internal winding parameters frequency hrang hrang nei te chu quantified a ni a, chu chuan transformer internal winding chu a danglamna lian tham a nih dan, frequency response amplitude, region inthlak dan leh frequency response inthlak dan azirin, tehna result a zirin, transformer chu nasa taka chhiat a nih leh nih loh leh maintenance a ngai em tih hriat theih a ni. Running transformer tan chuan frequency domain characteristic map chu a hmaa save a nih pawhin, a fault℃chu transformer dik lo coil inkara characteristic map danglamna tehkhin chuan a rel theih a ni. Dik tak chuan, transformer-a original winding characteristic map chu save a nih chuan, operation atana basis dik zawk pek a awlsam zawk a, post-accident analysis leh maintenance of transformers.

Huayi Power Transformer Winding Deformation Tester a thil awm dan te.

 

Hardware movement hian DDS digital high-speed sweep- frequency technique hmangin faults dik taka hriat theihna tur a hmang a, chu chu twisting, bulging, displacement, tilt, turn-to-Tun short- circuit deformation leh phase-to-Phase contact short{{{7}circuit te hi a ni.

Acquisition control hian high-integration microprocessor a hmang a, precision leh high{{1}stability nei component a thlang a, high- speed dual-channel 16-bit A/D sampling (Field test alters tap- changer, waveform curve changes alters alters alters alters alters alters alters alters alters alters alters alters alters alters alters alters alters alters alters alters alters alters alters alters alters alters Tap- changes obviously), repeat the same phase, the same phase is above 99.

 

He instrument hian measuring system pahnih, linear sweep frequency measurement leh segmented sweep frequency measurement a nei a, hei hi tun dinhmunah chuan domestic two technical genre measurement modes nen a inmil a ni.

Testing process-ah chuan transformer connecting bus chauh lakchhuah a ngai a, test zawng zawng chu cover chawi leh transformer disassemble lovin tihfel vek a ni.

 

Transformer tehnaah chuan wiring personnel te chuan signal te chu input leh output leads ah random takin an dah thei a, hei hian measurement result ah nghawng a nei lo. Wiring personnel te chu transformer tank-ah an awm thei a, break an nei thei a, chutiang chuan labor intensity an ti tlem thei ang.

Amplitude-frequency characteristics chu amplitude-frequency characteristic tester-a national technical indicator-te nen a inmil a ni. Abscissa (frequency) hi linear indexing leh logarithmic indexing hmanga siam a ni a, a siam dan pawh a inang lo hle. Chuvangin, printed curve chu linear indexing curve emaw logarithmic indexing curve emaw a ni thei a, a hmangtute chuan an mamawh angin an thlang thei bawk.

 

Instrument hi a intelligent hle a, signal output amplitude scale pawh software hmangin automatic in a siamrem bawk. Amplitude sang ber chu ±10V a ni a, sampling frequency pawh automatic in a siamrem bawk.

Instrument hian linear sweep- frequency system hrang hrang tehna function a nei a, linear sweep measurement scan frequency 2MHz thleng, frequency scan interval chu 0.25kHz, 0.5kHz leh 1kHz a ni a, chuvangin transformer deformation atan analysis tam zawk a pe a ni.

 

Historic curve comparison analysis pe la, a rualin historical curve observation tam tak load la, arbitrary curves a thlang thei a, horizontal leh vertical analysis a ti thei bawk. Expert intelligent analysis leh diagnosis system hmanga thuam a nih avangin, transformer winding dinhmun chu automatic-in a diagnose thei a, a rualin curve 6 a load thei a, curve tina parameter inzawmte chu automatic-in a chhut thei a, winding-a deformation chu automatic-in a diagnose thei a, reference conclusion of diagnosis a pe thei bawk.

 

Software management function hi a chak hle a ni. Huayi Power-a product design engineer-te chuan field service mamawh chu an ngaihtuah kim vek a, software hian transformer winding deformation diagnosis atana basis pe turin environmental condition parameters a save nghal vek a ni. Measurement data chu automatic-in analyze leh saved a ni a, electronic document (word) chu save a ni a, color printing function pek a ni a, chutiang chuan user chuan test report chu a output thei ang.

 

Measurement leh hman dan .

news-364-304

Transformer detect dan tlangpui chu a chunga kan sawi ang hian a ni. Huayi Power Transformer Winding Deformation Tester hi main measuring unit leh notebook computer atanga siam a ni ber a, chubakah measuring cable bik pathum, measuring clip leh grounding wire te a awm bawk. Main measuring unit system leh test sample te chu high frequency coaxial cable 50 hmangin an inzawm a, sweep frequency signal chu output port (excitation output) kaltlangin a kal a, signal clip (yellow) chu test tawh object chhungah cable connect hmangin a inject a Signal chu test tawh object atang chuan signal clip (green) hmangin lak a ni a, cable hmanga thawn chhuah a ni (response input); Synchronous reference signal chu test tawh object injection point atang chuan signal measurement hmangin kan la a, cable hmangin input (reference input) ah kan thawn chhuak thin. Test case-a shield leh testing cable chu rintlak taka connect leh grounded a ngai a ni. Transformer lian tak wire leh fuel tank te hi iron-core earthing bushing hmangin an inzawm tlangpui a, common ground point angin, transformer case chu grounded a ni.

 

Rorelna thurin .

1. Waveform tehkhin dan .

Normally operating transformer windings te hi pathum-phase characteristic pathum nen an inzawm tha hle. Accident pakhatin winding deformation a thlen loh chuan accident hma leh a hnua curve te chu a inmil ber a ni.

Winding a deformed hnuah chuan accident hma leh a hnua curve te chu a inthlak danglam tih a chiang a, a inmil lo a, correlation pawh a tha lo hle. Deformation lai hian lower frequency band 0.5-200kHz-a curve peak value chu a shift ang a, frequency a dah belh emaw a tlahniam emaw a ni ang. Peak value nena inmil decibel zat pawh a danglam ang a, peak point awm zat pawh a tlangpuiin a tlahniam ang.

 

2. Rorelna Theory .

Accident hmaa transformer frequency response curve nen khaikhin chuan transformer hian original frequency response curve data a neih a ngai a ni.

Model inang leh siamtute nen khaikhin la, a rualin thil siamtute nen khaikhin bawk ang che.

Phase-to-phase comparisons chu pathum-phase emaw single-phase transformer pathum tan chuan a awm thei.

Rorelna chu characteristic value pahnih atanga siam a ni a, chungte chu mean square error exy leh correlation coefficient PXY a nih chuan exy a tlem poh leh curve pahnih tan a hnai zawk a ni. PXY hnaih poh leh 1 a nih chuan curve pahnih inmilna a sang zawk. Frequency band pahnih emaw a aia tam emaw chuan pxy .<0.98 and Exy>3.0 a ni a; emaw PXY emaw a ni thei bawk.<0.9 and Exy>1.5, or Exy>4.5 leh PXY chu 0.99 chauh a ni a, transformer tan deformation a thlen dawn a ni. Method dang, "Oil chromatographic analysis", "winding DC resistance measurement" "short-circuit impedance" "No-Load Test" leh transformer winding a deformed em tih te kimchang taka endik theihna tur te nen a inzawm chuan.

Huayi hi China rama electric power hmanrua (repair, test) qualification leh power test equipment atana enterprise professional research leh developing a ni a. Configuration hrang hrang nei electrical test products customize-naah a specialise a, chu chu voltage hrang hrang a ngai a ni..

Huayi hian high-voltage electrical testing equipment leh instrument hrang hrang zirchianna leh hmasawnna kawngah a thiam hle! Darkar 24 chhung service a pe a: 400-060-1718. Huayi chungchang hrechiang duh tan kan website: www.wh-huayi.com ah hian en theih a ni.

Inquiry thawn rawh .
Inquiry thawn rawh .