XZB-5000KVA/1000KV A rilru a hah lutuk chuan a rilru a buai em em a, a rilru a hah lutuk chuan a rilru a buai em em bawk a.

 May 17, 2024

 Message pakhat dah la .

 

Test hman dan leh a mamawh .

750kV leh 750kV hnuai lam GIS AC withstand Voltage Test, Test Frequency 30-300Hz,Test voltage 1000kV aia tam lo, test hun 1min.

Hnathawh dan tur .

Environment Temperature:-10 .0C –50 0C;

2. Relative Humidity: 90%RH aia tlem emaw, a tlukpui emaw .

3. Altitude: 1000m aia tlem emaw, a tlukpui emaw

Technical parameter leh function pawimawh ber berte .

rated theihna:5000KVA;

Input power: 3 Phase 380V, 50Hz;

Rated voltage:1000KV;

rated current: 5A;

Hnathawh tam dan:30-300Hz;

Output waveform:Sine wave .

Waveform Deviation Factor:Distortion rate of output voltage waveform 1% aia tlem emaw, a tlukpui emaw;

Hnathawh hun:Rated load hnuaiah hna thawh chhunzawm zel 60min;over voltage vawi 1.1 1min;;

Temperature rise:Rated load hnuaiah chuan continuous working 60min a phalsak a, chu mi hnuah chuan temperature chu 65K aia tlem emaw a tlukpui emaw a ni.

Quality factor: Q 30(f=45Hz) aia tam emaw, a tlukpui emaw a ni.

Defensive function: Over-Tunlai, over-Voltage leh flashover protection te chu test tawh product atan dah a ni (Frequency Conversion Power Supply en la, a chipchiar zawkin en rawh).

A dikna:System A hman tangkai dan 1.5;

Test standard a ni a .

GB10229-88 《Reactor Express

GB1094 《Power Transformer Express ah hian a awm a.

GB50150-2016 《Electrical hmanrua hman dan tur tehfung leh Commission Test Express

DL/T 596-2021 《 Electrical hmanrua hmanga invenna test dan Express

GB1094.1-GB1094.6-96 《Shell venhimna grade Express

GB2900 《Electrotechnical terminology hmanga thil tih theih a ni.

GB/T16927.1~2-1997 《High voltage test dan Express

Capacity tehna 1.1.

Test system A vaiin 5000KVA/1000KV, Design 4 Reactors, leh Single Reactor tan 1250KVA/250KV/5A/140H a ni.

Verification: Reactor pali hmangin series-ah (coefficient 1.2), chutah chuan L{{1}*4*1.2=672h

Test frequency:F=1/2π√LC=1/(2×3.14×√672×0.015×10-6)=50.13Hz 1000 a ni.

Test current:i=2πFcutest =2π×50.13×0.015×10-6×1000×103=4.72A

Test inzawmkhawm .

Inkawpchawi

Test object .

Reactor 1250KVA/250KV*4 a ni.

Excitation transformer atanga chhuak tur thlan chhuah .

Test voltage (KV) 1000 a ni.

750KV GIS a ni.

Reactor 4 hmang la, series ah .

40KV a ni.

1000KV aia tlem emaw a aia tlem emaw

 

System leh Parameters te .

Transformer ngaihnawm tak . jlb a ni.-200kva/ a ni.20/40KV/ a ni.0.4KV a ni. 1ruahman

A chhuahna tur hmun:200KVA;

input voltage:0-400V,a phase pakhat;

A chhuahna tur voltage:20/40KV

structure:oil chi hrang hrang;

A rih zawng:1t;Frequency chak thei tak power supply a awm bawk. CHXB- tih a ni.200KW/380V a ni. 1 ruahman

Rated output theihna:200kw

Hnathawh theihna tur power supply: 380±10%V(single/3phase),power frequency

Output voltage:0 –400V,single,

Rated Input Current:500A

rated output current:500A a ni.

Voltage a awm chuan 0.01KV a ni ang.

Voltage tehna dik tak:1.5% .

A chhuah tam dan:30 – 300Hz

Frequency control resolution: 0.1Hz aia tlem emaw, a tlukpui emaw

Requency dinhmun nghet tak: 0.1% a ni.

Running time:Rated capacity 5min chhunzawm zel tur a ni.

Continuous at rated capacity 5minmax temperature 65K aia tlem emaw a tlukpui emaw a temperature

The Noise Level: 50DB aia tlem emaw, a tlukpui emaw .

A hnuaia function te hi implement theih a ni .

Variable frequency power supply chu vertical leh horizontal-a dah a ni a, a bik takin field operation leh observation atan a tha hle.

A chhung leh pawnah chuan special shock- rubber support feet leh protective aluminum box absorbing a awm a, hei hian a phurh chhuah laiin bump vibration a ti tlem thei a, lifting laiin shock a ti tlem thei bawk. guaranteed long-Term stability leh variable frequency power supply rintlak tak;

Parameter Display:Thawhtlin emaw pawn lam mouse emaw screen lian LCD display system. Resonant voltage (test hmaa target voltage set), test frequency, measurement frequency, low-voltage voltage, low-voltage current, voltage hun tuar thei, overcurrent protection, overcurrent protection, flasover protection, step boosting leh timing, operation mode switching, capacitance, capacitance, frequency te, frequency te inthlak danglamna te, voltage query te pawh a lang thei a, voltage curve leh curve te chu a ni thei bawk. fiahna.

Parameter Setting:Large Screen Touch LCD color screen leh external mouse direct-a parameter hrang hrang setting chu a zo a, start frequency, stop frequency, start voltage, phase boost leh timing, voltage divider variation ratio tehna, excitation variation ratio tehna, overvoltage protection, overcurrent protection, flashover protection, test mode, capacitance leh inductance frequency interchange, parameter setting, parameter setting leh help, etc.

Test mode:Screen leh pawn lam mouse hman dan,State pathum kal mek a awm a, chungte chu automatic, semi-automatic leh manual a ni. Boosting, tuning (manual leh automatic te pawh tel), segmenting pressurization leh timing, running state, mode switching, fault warning, frequency interchange capacitance leh inductance hman dan, etc. te neiin, etc.

Protection function leh information prompt: pressure sang lutuk overvoltage venna, pressure hniam lutuk venna, overcurrent protection, leh detuning protection, zero, flasover protection, emergency shutdown, voltage venna leh protection function dang tam tak nen

Data Storage Function:Test Results Saving (Manual Saving), Print, Upload, Check back, etc.

Test Result:Manual emaw automatic test zawh hnuah test result interface-ah hian test-a parameter chipchiar tak takte chu a lang thei a. Test tihtawp a nih chuan interrupt status chu a rawn lang thei a ni. Parameters te hi memory ah save theih a ni a, chu chu non-volatile memory a ni a, test record 50 a nei thei bawk.;

Data Review:Test result saved data chu screen-ah a lang thei. USB interface a nei bawk a, chu chuan data output a print thei a, device-in a phurh printer chu a hmang thei bawk(printer chu customer duhthlanna a ni. Customer chuan he thil phut hi a nei a nih chuan contract-ah a tarlang tur a ni)

Automatic Voltage Stabilizing Function: System chuan set test voltage emaw manual boost result emaw angin stable test voltage chu automatic-in a track a, a vawng reng bawk a,Voltage stability chu 1.0% thlengin a thleng thei a

Frequency range leh frequency resolution chu set theih a ni:Frequency modulation range chu {{0}Hz, {{1}Hz,200-300Hz, set ngai ang zelin, tuning process ti chak thei ang berin set theih a ni a;frequency resolution chu a tul angin set theih a ni a, chu chu 0.1Hz,0.5Hz,0H.0H.

Frequency regulation chu rough leh fine tuning-ah then a ni a,test resonance point chu automatic-in hmuh theih a ni a,test process pumpuiah resonant frequency chu a drift lo tih hriat a ni ang

A rih zawng:85kg vel a ni.

HV reactor 100 a ni. dk- a ni.1250kva/ a ni.250kV 4nos a ni.

A chhuahna tur hmun:1250KVA;

Rated voltage:250KV;

rated current:5A;

Inductance:140h /nos a ni.

Quality factor:Q 30 aia tam emaw, a tlukpui emaw (f=45Hz);

structure:oil chi hrang hrang;

A rih zawng:1.2t vel;

Capacitive voltage hmanga in\\henna a ni. FR 10 a ni.C-1000KV/ a ni.500Pf 1 a ni.ruahman

Rated voltage:1000KV;

HV capacitance:500pf;

dielectric loss:tgσ 0.5% aia tlem emaw, a tlukpui emaw;

Voltage divider ratio:10000:1.

A tehna dikna:Active value 1.5 .

A rih zawng:150kg vel;

Packing list a awm em .

Configuration hmanrua list .

Aih

hming

Model leh specification .

hlawm khat

QTY 100 a ni.

Remarlk 100 a ni.

1

Transformer ngaihnawm tak .

JLB-200KVA/20/40KV/0.4kv

ruahman

1

 

2

Variable-Frequency power supply a awm bawk.

CHXB-200KW/380V a ni.

ruahman

1

 

3

voltage sang tak a awm a, reactor a awm bawk.

DK-1250KVA/250KV a ni.

ruahman

4

 

4

Capacitive voltage hmanga in\\henna a ni.

FRC-1000KV/500pf a ni.

ruahman

1

 

6

Internal connection wire te .

 

ruahman

1

 

Document list 100 a awm.

Aih

hming

hlawm khat

QTY 100 a ni.

Thusawi .

1

Ex-Factory test report a ni.

Copy 100 a ni.

1

 

2

kuta thawh

Copy 100 a ni.

1

3

Product certificate leh customer te .

Comment Card 100 a awm bawk.

ruahman

1

 

After-Sales service .

Received, Terms of Contract about related commissioning of equipment, a tul chuan supplier chuan On-Site Technical Support Services of relevant technicians of the equipment-ah mawhphurhna a nei ang. Buyer chu hmanruaa site acceptance test hmasa ber leh Buyer-a operation personnel kaihhnawih technical training zawhfel turin kaihhruaina leh puih. A pawm zawh chuan Buyer chuan a pawm zawh tawhna finfiahna atan supplier-in a pek equipment acceptance/maintenance report (attached table en rawh) chu a fill up ang.

Supplier chuan hmanrua set atan warranty a nei ang a, warranty hun chhung chu a pek chhuah atanga kum khat a ni ang. Warranty hun chhung hian supplier chuan a thil siam part leh component te chu a thlawna enfiah leh thlak a nih theih nan mawhphurhna a nei tur a ni (equipment part leh components te chu wiring ang chi consumable accessories tel lovin)

Warranty hun chhung kum khat a pelh chuan product supplier chuan lifetime maintenance a pe ang. Warranty hun chhung chu kum khat aia rei a nih chuan supplier chuan maintenance fee pangngai (maintenance hour fee, material fee, leh additional fee) a pe ang.

Implement all-Weather Technical Response Service, he set of products hman chungchanga harsatna awm thei chungchangah phone emaw fax emaw i dawn hnu darkar 8 chhungin technical solution pe rawh.

Hman dan dik lo avanga hmanrua a chhiat emaw, hman theih loh emaw a nih chuan he warranty hian a huam lo.

Inquiry thawn rawh .
Inquiry thawn rawh .