Kan company siam PDS800 handheld partial discharge tester hi multi-functional handheld instrument a ni a, chu chuan transient ground voltage, ultrasonic, ultrasonic, leh high-frequency current detection methods hmanga hmanrua partial discharge conditions a hmuchhuak a Cables atan a tha a, electrical equipment GIS, switch cabinet leh transformer te partial discharge detection a ni. Tin, a hnathawh dan chu a hnuaia mi ang hian a ni a;

1. Lei voltage hun rei lo te chhunga .

High-voltage electrical equipment-a partial discharge a awm chuan, discharge electric chu discharge point bula grounded metal part-ah a pungkhawm hmasa a, electromagnetic wave a siam a, kawng tinrengah a darh vek a ni. Discharge atanga electromagnetic wave lo chhuak chu metal box emaw gas-insulated switch emaw seams kaltlangin a kal a. Gasket chu a darh chhuak a, chutih rual chuan transient ground voltage a siam bawk a, chu chu hmanrua metal box chunglam atang chuan leiah a kal kual a ni.

Transient ground voltage partial discharge monitoring chu normal power equipment hian 3 leh 100MHz inkar transient ground wave signal a pe chhuak tam lo tih thudik bulpui atanga siam a ni. He principle hi partial discharge enfiah nan hman a nih chuan pulse signal leh voltage phase inzawmna ngaihtuah a ngai lo va, chuvangin power grid hmanrua tam tak routine state monitoring atan hman theih a ni.

Power station-a auxiliary equipment, electronic ballast hmanga lighting system, voltage regulation atana semiconductor switching elements hmanga charging system, main circuit charged display atana charging system, etc. te hian a chunga frequency band-a signal a siam theih avangin, he method hi partial discharge monitoring technology siam chhuah hunah chuan hman tur a ni a, chutiang interference signal tihbo leh thliar hran chu ngaihven tur a ni. A tul chuan test instrument dang, spectrum analyzer leh oscilloscope te hmangin partial discharge tihchian theih a ni a, interference signal te pawh thliar hran theih a ni bawk.

2. Ultrasound 1000 a ni.

Electrical equipment hian discharge laiin sound wave a siam chhuak thin. Discharge atanga sound wave lo chhuak frequency spectrum chu a zau hle a, Hz sawm atanga MHz engemaw zat thlengin, chutah chuan 20kHz hnuai lama signal frequency chu mihring bengin a hriat theih a, he frequency chung lam ultrasonic signal hi ultrasonic sensor hmangin a dawng tur a ni. Discharge-in a tihchhuah energy leh sound energy inzawmna ang chuan, ultrasonic signal-a sound pressure inthlak danglamna hian partial discharge-in a chhuah chhuah energy inthlak danglamna chu a entir a, chu chu ultrasonic signal-a sound pressure tehna hmangin a chakna chu a infer theih a, chu chu ultrasonic signal detection of partial discharge principle bulpui ber a ni.

3. UHF .

Insulation strength leh breakdown field strength of power equipment insulators te hi a sang hle. Range tlemtea partial discharge a awm chuan breakdown process a rang hle a, steep pulse current tak tak a siam ang a, rise time 1Ns aia tlem leh GHz engemaw zat thlenga electromagnetic waves excitation frequency a siam ang. Ultra-high frequency (UHF) partial discharge detection method-a principle bulpui ber chu Ultra-high frequency electromagnetic wave signals chu power equipment-a partial discharge laiin a lo chhuak a, chu chuan partial discharge chungchangah information pawimawh tak tak a hmu a, partial discharge monitoring leh ultra-high frequency detection a hmu thei a ni. Frequency band chu 300MHz-1.5GHz a ni. On-site equipment condition a zirin UHF sensor leh external UHF sensor te pawh hman theih a ni.

On-site corona interference hi 300MHz frequency band hnuaiah a awm ber avangin UHF method hian-site corona leh interference dangte chu effective takin a pumpelh thei a, sensitivity sang tak leh anti-interference ability a nei a, partial discharge charged detection, positioning, leh defect type identification te pawh a thleng thei a ni. leh advantage dangte pawh a awm bawk.

4. Frequency sang tak current .

Insulation strength leh breakdown field strength of power equipment insulators te hi a sang hle. Range tlemtea partial discharge a awm chuan breakdown process a rang hle a, pulse current steep tak tak a siam ang. Partial discharge hi high-voltage electrical equipment chhungah a awm a, chu discharge current chu ground wire-ah leiah a darh a ni. Partial discharge atanga pulse current lo chhuak chu equipment ground wire-ah hmuh theih a ni. High-Hetiang hmanga siam Frequency Current Sensors (HFCT) hian a tlangpuiin Rogowski coil an hmang thin. High-frequency current sensor hmanga electrical hmanrua grounding wire hmuhchhuah hi non-intrusive detection method a ni. Thil hmanrua hmuhchhuah mek chu khar a ngai lo va, a awlsamin a rintlak bawk.