Test program eng pawhah hmanraw dik tak hman a pawimawh hle. Thil hmanrua te chu calibrate tur a ni a, a dinhmun a tha tur a ni a, operator thiam tak takte hman tur a ni. Calibration atana hman tur test equipment eng pawh hian test tur hmanrua chu a let hnih zetin a dik zawk tur a ni. Thil hmanrua atana quality emaw regulated power source emaw hmanga voltage, frequency, leh waveform variation te hian result dik lo a siam theih avangin fimkhur tur a ni. Thil hmanrua zawng zawng chu a instruction manual angin hman vek tur a ni.
Electrical power system hmanrua test-naah hian insulation adequacy, electrical property, protection leh control, operation, leh thil dangte chu system pumpui nena inzawm angin enfiah a ni. Heng check thenkhat hi DE{-energized component tests, instrumentation leh relay operation leh calibration test hmanga tih theih a ni a, control circuits te energized functional testing, power circuits megger testing, phase-power circuit test te, leh service testing te hmanga tih theih a ni bawk.
System leh an component-a electrical testing neih chhan chu pahnih-fold a ni. A hmasa ber chu hmanrua dah dan enfiah a, component leh systems test te tih a ni a, chu chuan, chak taka a awm chuan system chu a thawk tha ang tih enfiah a ni. A pahnihna chu hmanraw chhe zel hriat theihna turin nakin lawka test-naah tehkhin nan baseline test result set siam a ni. System chu a tir lamah chuan hmanrua siamtuin a tarlan component check, inspection, leh test bik hmangin a chhiat leh chhiat leh chhiat loh enfiah tur a ni. Tichuan, system components te inzawmna chu enfiah tur a ni a, de-energized leh energized method hmangin, components te inzawmna leh hnathawh dan dik tak, on/off control, system process interlocks, leh protective relaying function te pawh a awm tih finfiah tur a ni. A chunga test te hi a zawh chuan system chu energized theih a ni a, operational test leh measurement te pawh tih tur a ni. Test-naa step leh result zawng zawng chu uluk taka enfiah tur leh nakin lawka test tur atana hman tur leh nakin lawka test result nena khaikhin tur a ni. Component test inang tam tak a tir lama kalpui chu maintenance program-a tel angin regular interval-ah tih a ni ang. Results thar hi a tir lama result nen khaikhin a ni ang a, chutah chuan variation te hian insulation chhiatna emaw hmanrua bawlhhlawh emaw ang chi harsatna a lantir thei a ni. Step hrang hrangte chu system leh hmanrua te enfiah a, general system leh specific equipment test plan siam te, inspection leh check te, component testing tih te, wiring kal zel dan te, check control function te enfiah te, instrument leh relay te calibrate te, circuit thenkhat te energize te leh order bik a hnathawh dan dik te enfiah te a ni a, a hmasa berah chuan a hnathawh dan tur dik leh dik loh enfiah a ni bawk.
