Insulation pakhata DC potential hman a nih chuan, a chhuak current flow chu 1000 atanga siam a ni.Components te hi hetiang hian a ni:
 
(1) Capacitance-Curngy Charging. Capacitance-Charging current chu bushing capacitance atanga lo chhuak capacitor atanga charge absorb atanga current lo chhuak a ni. He current hi hun hman dan a ni a, chu chu applied voltage, insulation resistance, leh circuit-a time constant-ah pawh a innghat a ni.
(2) Dielectric-absorption current. Dielectric-absorption current chu hmanrua pakhat charge lai a dielectric-a absorb leh trapped current a ni a, hmanrua a discharge hnua tihchhuah a ni. He current hi test voltage, capacitance, leh time atanga chhut theih a ni. Air-cooled leh hydrogen-cooled AC rotating machine-ah chuan dielectric absorption hi temperature a zirin a danglam thin.
(3) Lei chung lam a leakage current. A volume kal tlanga insulation chunglam atanga current kal tlang chu surface leakage current a ni. Rotating machine-a armature leh field windings-te insulation resistance tehnaah chuan (rated 1 hp, 750 W or greater), surface leakage current sang tak chu rotating machine-a awm, moisture emaw, partly conductive contamination chi dang emaw avanga lo awm a ni tlangpui.
(4) A then a chhuah (corona current). Hei hi voltage stress hian critical value a pelh chuan insulation system-a transient gaseous ionization atanga lo chhuak localized discharge chi khat a ni. Partial discharge hi duhthusam a ni lo va, tihbo a ngai a ni. Test voltage sang tak avanga conductor kil hrual hrual a boruak overstressing vang a ni. Shielded power cable system (rated > 5 kV) ah chuan humidity emaw thli emaw hian corona current a tisang thei a ni.
(5) Volumetric leakage current. Volume insulation ngeia current luang chhuak chu volumetric leakage current a ni. Insulation dinhmun endikna atana ngaihven ber chu current a ni. Shielded power cable system (rated > 5 kV), humidity, condensation, leh termination surface-a ruahtui tlak tamna chuan surface leakage current leh volumetric leakage current a tipung thei a ni. Surface leakage current leh volumetric current te chu a inzawm khawm chuan quotient a ni a, a voltage leh insulation resistance a awm bawk. AC rotating machine lian tak takah chuan 10,000 kVA aia sang leh 6000V aia sang rated, moisture, end windings-ah chuan surface leakage current leh volumetric leakage current a ti sang a, a bik takin bawlhhlawh pawh winding-ah a awm a ni. Hun kal zelah insulation hi a chak lo thei a, kum upat hian test laiin current hrang hrang a tisang thei a ni.
 
DC testing tih nan hian Wuhan Huayi Electric Power Company chuan DC Hipot Tester an siam a, hei hi an hlawhtling hle. He product hian technique thar, material thar leh component thar, output power sang tak nei, volume tlem, light weight, etc. te a hmang a, chu chu stable over-voltage, over-tuna, zero position switching protection, 0.75 times voltage latch function, time relay hmanga thuam a ni a, test-naah audio alarm a set thei a ni. Device pumpui hi rintlak a ni a, hman leh phurh awlsam a ni a, a bik takin Power Department field test-ah hman a ni.DC voltage hi 400kV thleng a ni thei a, hman a awlsam hle.