Very Low Frequency (VLF) cable tester hmanga cable test huna kan hriat tur chu eng nge ni .

 Jun 10, 2025

 Message pakhat dah la .

 

Cable test nan frequency hniam tak (VLF) hipot tester i hman hian a hnuaia mi te hi hriat tur a ni:

Test hmain .

Engineer-te chu an hmanrua an hman theih hmain an zirtir a, assessment an pass hmasak phawt a ngai a ni. Equipment parameters thlak danglam khap tlat a ni.

VLF tester chu rintlak takin grounded a ngai a; Grounding terminal chu test neih chhunga thil test mek nen nghet taka inzawm tur a ni a, circuit hawn chu khap tlat a ni High-voltage output chu 0 a nih leh nih loh enfiah a ngai a, test object connect hunah reset state-ah a awm bawk.

Tester calibrate leh loading awm lovin voltage sang tak siamrem hian leakage current indicator a lantir a, chu chu initial current a ni a, chu chu normal a ni a, test accuracy a nghawng lo.

Insulation resistance tester hmangin test hmasa la, cable te chu electrical hmanrua dang hmangin discount rawh. Cable sei zawng hi a tawi (meter 300 aia tlem lo) a, test specimen capacitance 0.05 μF aia tlem a nih chuan test voltage tihpun a ni thei lo. Chutiang a nih chuan high-voltage capacitor chu parallel-in connect rawh.

Test neih chhung hian .

Test hi phase tinah tih theih a ni. Test sample cable-a capacitance value chu test equipment-a load capacity range chhunga a awm chuan, test sample cable-a phase conductor pathum- chu parallel-in a inzawm thei a, withstand voltage test chu a rualin a ti thei bawk. Test Voltage Peak: UMAX=3UO, UO chu cable conductor leh ground inkar emaw, metal shield inkar emawa rated operating voltage a ni.

Power supply on la, test frequency, time, leh voltage te chu set la, chutah chuan voltage rise test chu start rawh. Voltage rise process chhung hian high-voltage circuit chu ngun takin enfiah la, test specimen cable atanga aw pangngai lo awm apiang chu ngaithla rawh. Test voltage a thlen chuan test hun recording tan la, test voltage value chhiar tan rawh.

Power generator chu 8kW aia tam a ni tur a ni. Generator output frequency chu a stable tur a ni. Frequency converter power supply emaw digital frequency generator emaw hmang la.

Test zawhah .

Test hun a lo thlen chuan instrument chu a khar nghal mai ang. Power on leh voltage rise process tan hnuah, i interrupt a ngai a nih chuan power switch kha off suh. Chu ai chuan, power off hmain test sample chu a full discharge theih nan stop button leh discharge rod hmang ngei ngei tur a ni.Power indicator light a eng lo emaw, screen-in device a on laiin display a lantir loh emaw chuan fuse a kang chhuak tawh mai thei. Fuse thar hmangin thlak mai tur a ni.

Inquiry thawn rawh .
Inquiry thawn rawh .