DC Hipot Test hi electrical hmanrua emaw thil emaw insulation performance tehna atana hmanraw pawimawh tak a ni a, mahse test process chhung hian a hnuaia point te hi chhinchhiah a ngai a, test dik leh him loh enfiah a ngai a ni:
1. Test hmaa inbuatsaihna .
Thil hmanrua enfiahna: Test instruments (DC High-voltage generator ang chi) te chu a dinhmun a tha a, a calibrate dik em tih enfiah tur a ni.
Environment dinhmun: Test environment chu a vawt a, a thianghlim tur a ni a, humidity sang tak emaw conductive dust emaw a awm loh nan, test result a nghawng loh nan.
Device Status: Test hnuaia device awm chu power-off state-ah a awm tur a ni a, a chhungah residual charge a awm loh nan enfiah tur a ni.
2. Test voltage thlan dan .
Standard Voltage: Test voltage chu hmanrua emaw, a kaihhnawih standard emaw (IEC, GB, etc. ang chi) technical specification angin hriat tur a ni a, a tlangpuiin rated voltage aiin a let 1.5 atanga 3 velin a sang thei ang.
Step Up Rising Voltage: Test neih chhung hian voltage sang tak avanga device a chhiat loh nan voltage chu tihpun zauh zauh tur a ni.
Voltage Stability: Test result nghawng thei inthlak danglamna awm lo turin test voltage chu a nghet em tih enfiah tur a ni.
3. Testing neih chhunga fimkhur dan tur .
Time Control: Test hun hi a tlangpuiin (minute 1 atanga 5 vel ang chi) a ni a, chu chuan hun rei tak pressure sang tak avanga a lum lutuk emaw, insulation aging emaw a awm loh nan a ni.
Monitoring Current: Test neih chhung hian leakage current chu enfiah a ni. Current chu a pangngai lovin a pung a nih chuan insulation a chhiat thu a tarlang thei.
Safety Protection: Operator chuan invenna hmanrua, insulation gloves leh pheikhawk te a ha tur a ni a, a hlat zawng pawh a him tur a ni.
4. Attention hnua-Test treatment .
Discharge Operation: Test zawhah test mek device chu residual charge avanga electric shock hlauhawmna awm lo turin a chhuak kim vek tur a ni.
Result Recording: Test voltage, leakage current, test hun leh data dangte chu a hnua zirchianna atan chipchiar takin record rawh.
Thil hmanrua enfiah: Test zawha hmanrua awm dan leh insulation dinhmun enfiah la, a chhe emaw, a chhe emaw a awm loh nan.
5. Case bikte enkawl dan .
High Humidity: Ambient humidity a sang lutuk chuan test result a dik lo thei. Chuvangin, boruak vawt takah test chu ti leh turin kan fuih a che.
Device Exception: Test neih chhunga exception (smoke emaw rim ang chi) a awm chuan test kha titawp nghal la, a chhan zawng rawh.
Long distance cables: Long distance cable tan chuan capacitance effects ngaihtuah tur a ni a, voltage pawh zawi zawiin tihpun a ngai a, test hun pawh tihzauh a ngai bawk.