Lei hnuaia cable dah hmanga power transmission an hmuh chu lei hnuaia power cable an ti a. Heng cable te install man hi a sang hle nachungin rintlak anga ngaih a ni.

Overhead lines chu hmun hla tak atanga landscape kal tlangin hmuh theih a ni fo a, chutih laiin lei hnuaia cable te chu overhead line hman a nih loh chuan hman theih loh a ni a, chu chu thing leh mau chhehvel emaw, maintenance conditions in overhead construction hman phal lohna hmunah emaw a ni.

Lei hnuaia cable test dan .

Cable te hi a hnuaia fault te hi test a ni.

1. A tawi-circuit dan .

2. Discontinuity .

3. Leilung sualna .

Underground cable-a fault awmte chinfel nan kan company chuan cable fault detecting test equipment kan siam a. Chumi

HYDGC-H cable fault tester hi cable fault detection instrument kimchang tak a ni a, a hman dan tur pawh a hriat theih loh. High-resistance flashover faults, high- leh low-resistance grounding, short circuit, cable disconnections, poor contacts, etc. te tan cables a test thei a, acoustic factory point instrument hmanga thuam a nih chuan fault point awmna dik tak chu dik takin a hriat theih a ni. Cable leh communication cable chi hrang hrang leh voltage level test na atan a tha. Power cable fault testers set kimchang chu hmun thum a awm a, chungte chu flash detection, tracing, leh positioning te an ni.

Cable Fault Tester (Flash Tester) hmang hian resistance hniam, resistance sang, short circuit, open circuit, leakage fault, leh cable hrang hranga flasover fault te hriat theih a ni. Lei hnuaia cable awmte fault point awmna hmun, cable sei zawng, leh cable sei zawng dik takin a hmu thei a ni. Kawngpui phum a ni. Test dik tak, intelligence sang tak, wide adaptability, stable performance, lightness, leh portability te mizia a nei a ni. Instrument hian high-definition display a nei a, interface pawh a friendly hle bawk.

Cable tracing leh fault location te hi path meter, point meter, t-type probe, A-frame, earpiece, etc. te atanga siam a ni a, he instrument hi cable fault location testing atana hmanraw bik a ni. Cable hrang hrang metal conductor hmanga test nan a tha hle (line pairs, sheaths, shielding layers). A hnathawh ber chu ground insulation point dik lo positioning leh test te, cable paths hmuhchhuah te, leh cable burial depth test te a ni.

Tester tangkai tak a ni. Testing chu fail-safe, fast, leh dik tak a ni. Low{-voltage pulse method leh high-Voltage flashover method hmangin cable fault hrang hrang an hmu thei a. Flasover leh high-Cable-a resistance faults te chu direct-in kang lovin direct-in test theih a ni. Fault awmna dik tak chu acoustic legal point meter hmangin dik takin a hriat theih a;

 