Operating impulse test chu eng nge ni .

 Mar 24, 2025

 Message pakhat dah la .

 

Operating impuse test hi operating overvoltage conditions hnuaia electrical equipment-a insulation performance endikna atana hman thin test method a ni. Power system-a switching operation, failure emaw, transient process dang emaw hmanga overvoltage siamte chu a simulate a, chu chuan hmanrua chu a tak taka hmannaah chutiang shock chu a tuar thei tih a tichiang a ni. A hnuaia tarlan te hi Operational Impact Test-a thil langsar ber berte chu an ni:

1. Waveform ziarang .
Standard Waveform: Operating shock test atan hian 250/2500μs waveform (Wavefront time 250μs, half-peak time 2500μs) hi operating overvoltage-a typical characteristics simulate nan hman a ni tlangpui.
Long duration: Lightning shock test (1.2/50μs) nen khaikhin chuan operating shock waveform hi a rei zawk a, a chak zawk bawk.

2. Test tum .
Insulation performance tehna: Operating overvoltage condition hnuaia hmanrua te insulation strength test la, a chhe lo emaw, a flash over loh nan.
Simulate tak tak working conditions: Transient process hmanga overvoltage lo chhuak chu switching operation leh power system-a fault removal ang chi, hmanrua rintlak leh rintlak loh finfiah nan simulate rawh.

3. Test voltage .
Voltage Level: Operation impulse test voltage chu hmanrua rated voltage aiin a let 2-3 in a sang tlangpui a, a value bik chu hmanrua chi hrang hrang leh standard mamawh dan azirin a ruat thin.
Polarity thlan dan: Test-ah hian insulation performance kimchang taka tehna atan positive leh negative polarity shock pahnih a tel tlangpui.

4. Test hmanrua .
Impulse Voltage Generator: Impulse waveform a siam chhuak thei.
Voltage divider leh oscilloscope: Voltage waveform leh device response tehna leh record nan hman thin a ni.
Test objects: transformer, cable, circuit breaker leh power hmanrua dangte ang chi te.

5. Test standard 10.1.
Operational impact test-te chuan international leh national standard kaihhnawih a zawm tur a ni a, chungte chu:

IEC 60060-1: Voltage sang tak test dan tur.
GB/T 16927.1: China ram pum huap standard, high voltage test technology hmanga siam a ni.
IEEE C62.41: Operational shock waveforms awmzia leh hman dan.

6. Test result thlirletna .
Passed standard: Test-ah hian hmanrua chu a chhe lo va, a flash over lo bawk a, insulation performance chuan a mamawh a tlin lo.
Failure Condition: Thil hmanrua hian breakdown emaw insulation chhiatna a neih chuan a chhan zirchian a, design siam that a ngai a ni.

Inquiry thawn rawh .