GIS-a partial discharge TES atana technology thar chu eng nge ni .

 Mar 10, 2025

 Message pakhat dah la .

 

Kum 2025 thleng khan GIS (GAS-insulated switchgear) partial discharge test technology chuan hmasawnna nasa tak a nei a, technology thar hian sensitivity, efficiency leh intelligence lamah pawh nasa takin a tichangtlung a ni. A hnuaia tarlan te hi technology thar engemaw zat leh GIS partial discharge test-a an nihna te an ni:

 

1. Ultra High Frequency (UHF) hmanga hmuhchhuah theih a ni.
Principle: GIS internal partial discharge atanga siam UHF electromagnetic wave signal (300MHz~3GHz) chu hmuhchhuah a ni.
A thatna:
Sensitivity sang tak chuan partial discharge signal chak lo tak tak a hmu thei a ni.
Anti-interference theihna chak tak, complex electromagnetic environment atana hman tlak.
Application: Online monitoring leh offline testing-ah te hman a ni nasa hle a, a bik takin GIS hmanrua lian tak tak te chu long-term operation status assessment atan a tha hle.
2. Ultrasonic detection technology .
Principle: positioning leh analysis atana partial discharge (20kHz~300kHz) atanga ultrasonic signal lo chhuak chu a dawng a ni.
A thatna:
Local power supply chu dik takin a awm thei.
Partial discharge hriat hmasak nan a tha hle.
A hman dan: On-site inspection leh fault location atan hman a ni fo thin a, a bik takin GIS-a mechanical defect hmuhchhuah nan hman a ni.

3. Ultra-high frequency (TEV) hmanga hmuhchhuah theih a ni.
Principle: Ground potential metal surface-a partial discharge atanga lo chhuak transient ground voltage (TEV) signal chu hmuhchhuah a ni.
A thatna:
Hman awlsam, endikna rang tak neih theihna tur a ni.
hmanrua khawih lovin a hriat theih.
A hman dan: GIS hmanrua enkawl dan pangngai leh troubleshooting atan hman thin a ni.
4. Artificial Intelligence (AI) leh Big Data Analytics .
Principle: AI algorithm leh big data analysis technology hmangin partial discharge signals te chu intelligent identification leh diagnosis atan hman a ni.
A thatna:
Signal hriat theihna dik leh tha zawk siam that.
Preventive maintenance atana hmanraw chhiat awm thei te chu lo thlir lawk rawh.
Application: Online monitoring system nena inzawm chuan GIS hmanrua fing taka hman leh enkawlna atan hman a ni.
5. Multi-sensor Fusion technology hmanga siam a ni.
Principle: UHF, ultrasonic, TEV, leh detection method dangte nena inzawm, partial discharge signal chungchang kimchang taka zirchianna.
A thatna:
Test-na hmun zau tak leh rintlakna tihchangtlun.
Partial discharge chi chu a awm thei a, a dik zawkin a hriat theih bawk.
A hman dan: GIS hmanrua te chu a kimchang taka hmuhchhuah leh fault diagnosis atan a tha hle.

Heng technology tharte hian GIS partial discharge test hman tangkai leh dikna chu nasa takin a tichangtlung a, hmanrua rintlak taka kalpui theihna tur guarantee nghet tak a pe bawk. Technology hmasawnna chhunzawm zel a nih chuan GIS partial discharge test hi nakin lawkah chuan a fing zawkin a dik zawk dawn a, power system him taka kalpui theihna tur pawh a huam zau zawk dawn a ni.

Inquiry thawn rawh .