Electrical system leh hmanrua a lo than chhoh zel chuan thil siamtu leh engineer-te tan chuan an rintlak, an rei theihna leh an himna tur chu an dah hmain uluk taka test an nih theih nan a pawimawh hle. Test chi hrang hranga hman critical component pakhat chu test transformer hi a ni.

Test transformer hi chi thum-ah then theih a ni a – oil-immersed, dry{1}}type, leh SF6 gas test transformer te. Type tin hian feature leh application danglam tak tak an nei a, chu chuan testing mamawh hrang hrang atan a tha hle.

Oil-Immersed test transformer te hi voltage sang leh current pe thei leh power output lian tak tak an handle theih avangin an hmang tam ber a ni. Transformer, cable, leh switchgear te ang chi power hmanrua test nan an hmang thin. Heng test transformer-a insulation medium hi oil a ni a, chu chuan dielectric property tha tak a pe a, self-healing a ni. Heng transformer chi hrang hrangte hi high-voltage testing application atan an hmang a, chutah chuan dikna leh rintlakna a pawimawh hle.

Dry-Type test transformer te hian an safety level a san avangin an lar chho ta hle a ni. Heng transformer te hian oil emaw cooling system emaw an mamawh lo va, chu chuan eco-comfined space atan a tha a, a tha ber a ni. A lian lo zawk a, hmun khat atanga hmun danga phurh awlsam a ni bawk. Dry-Type transformer hi insulation resistance test, voltage withstanding testing, leh transformer testing te atan hman theih a ni.

SF6 gas test transformer te hian insulation property tha tak tak an nei a, hei hian high voltage leh high current testing atan a tha hle. Heng transformer te hian SF6 gas hi insulating medium atan an hmang a, maintenance requirement hniam tak an nei a, design lamah pawh an compact hle. Research laboratory-ah te, industrial testing-ah te, leh high voltage power equipment, circuit breaker, transformer, leh switchgear test-naah te an hmang tlangpui a ni.

Insulated cylindrical test transformer: hmanrua kimchang tak, a inmil theihna tur, voltage capacity series kimchang, a hnathawh dan famkim; Impedance a hniam a, system impedance pawh 5% aia tam a ni lo a, hei hian AC pollution test-a thil mamawh a tlin a; Electronic venhimna hmanrua rang tak, rintlakna sang tak.

Series High Voltage Test Transformer: Capacity tlem, voltage hniam, rit lo, phurh awlsam, connection tam tak, man to tak.

Test transformer hi electrical hmanrua test-na atana thil pawimawh tak a ni a, an himna tur leh rintlakna tur a ni. Transformer hman tur chi chu test mamawh, voltage leh current specification-ah te, a size leh safety requirement-ah te a innghat a ni. Chuvangin, result dik leh rintlak tak neih theih nan test transformer chi dik tak thlan a pawimawh hle.

 