Gas-insulated line (GIL), gas-insulated bus (GIB), leh gas-insulated system (GIS) te chu eng nge ni.

 Feb 18, 2025

 Message pakhat dah la .

 

Gas-insulated line (GIL), gas-insulated bus (GIB), leh gas-insulated system (GIS) te hi eng nge ni?
220KV GIS 2
Gas-insulated technology hi power transmission leh distribution-ah te hman a ni nasa hle a, a chhan chu a compactness, a rintlakna leh environment factors laka a inven avangin a ni. Gas-insulated line (GIL), Gas-insulated bus (GIB), leh gas-insulated system (GIS) te hi tunlai high-voltage power transmission leh distribution system-a component pawimawh tak tak an ni vek a.

1. Gas-inhalna line (GIL) .
Gas-insulated line (GIL) chu transmission system a ni a, aluminum conductors inzawmkhawm, insulating gas-a khat tube chhunga inkhung, a tlangpuiin sulfur hexafluoride (SF3) emaw gas mixture (SF3/N₂ ang chi) emaw a ni.

GIL-a thil pawimawh tak takte chu:
Long-Distance underground emaw tunnel-based power transmission atan hman a ni.
Overhead line nena khaikhin chuan transmission loss a hniam zawk.
Pawn lam boruak thil (tui, boruak bawlhhlawh, chi awm thei) laka inven theihna.
Overhead transmission line aiin space a mamawh tlem zawk.

GIL hman dan tur:
Underground High-voltage transmission (a bik takin khawpuiah chuan).
Power plant leh substation inzawmna.
Tunnel, bridge, leh boruak tichhe thei lo hmun, overhead line hman theih loh.


2. Gas-inhalna bus (GIB) .
Gas-insulated bus (GIB) hi substation chhunga power transmission atan hman a ni a, transformer, switchgear leh electrical component dangte chu enclosed SF₆{{1} insulation system chhungah connect a ni.
GIB-a thil pawimawh tak takte chu:
Traditional air ai chuan compact alternative a pe thei-insulated busbars.
Insulation property tha tak tak te hian dielectric loss tlem ber a pe a ni.
Khaw lum leh vawt, leivut leh boruak bawlhhlawh lakah a venghim.
Pawn lam bawlhhlawh avanga short circuit awm theihna a ti tlem.
GIB hman dan tur:
High-voltage substation (a bik takin GIS-type substation) te hi a ni.
Power plant leh industrial setup te chu space a tlem hle.
Electrical installation lian tak takah chuan rintlakna sang tak a ngai a ni.


3. Gas-inhalna system (GIS) .
Gas-insulated system (GIS) chu SF₆-insulated environment-a inkhung, high-voltage substation sang tak a ni. Circuit breaker, disconnectors, current leh voltage transformer, leh busbars te a huam a, chu chu sealed gas compartment chhunga dah vek a ni.GIS system-ah chuan component hrang hrang a awm tlangpui a, circuit breaker, disconnectors, leh voltage transformer te pawh a tel a, gas hmanga insulation a awm a, chu chuan efficiency leh reliability a ti tha zawk a ni. GIS hi substation leh power plant-ah te hman a ni nasa hle a, hei hian electric sem dan a ti awlsam a, enkawlna senso a tihtlem phah bawk.


Gas-insulated technology hian power transmission leh distribution system-ah rintlakna sang tak, efficiency, leh compact design a pe a ni. Enfiah fo thin, enkawl, leh SF3 monitoring te hian hun rei tak-Term Operational Safety a tichiang a ni. Gas-insulated line (GIL), Gas-insulated bus (GIB), leh gas-insulated system (GIS) te hian tunlai electrical infrastructure-ah hian hmun pawimawh tak an chang a ni. Gas chu insulating medium anga hman a nih chuan heng system te hian hlawkna tam tak an pe a, chung zingah chuan transmission capacity sang zawk, electrical hloh tlem zawk, leh rintlakna tihchangtlun te pawh a tel. Technology a lo thang zel a, gas-insulated systems chu power industry-ah a hluar zual zel a rinawm a, hei hian energy transmission tha leh nghet tak mamawhna sang zel phuhrukna kawngah a pui hle a ni.

Inquiry thawn rawh .
Inquiry thawn rawh .