The Variable Frequency Method — engtin nge 40V hian 2000V khup point chu a test theih ang?

 Jun 16, 2026

 Message pakhat dah la .

 

Q: Tunlai analyzer te hi kg 9 chauh an rit a, 120V hmangin an tlan a, chutih rualin khup point 4000V an teh thei. Engtin?

 

A: Physics bulpui ber a ni. A thuruk chu Variable Frequency Method a ni a, induced voltage formula hmanga hnathawh a ni.

 

Physics Formula chungchang hi:

• V=4.44 × f × N × Φm (chutah chuan Φm chu magnetic flux sang ber a ni a, N chu turn a ni a, f chu frequency a ni)

 

A Hmasawnna chu:

• Magnetic saturation hi maximum flux (Φm) ah CHAUH a innghat a ni.

• Flux atan ziah thar leh a ni: Φm=V / (4.44 × f × N).

• 50 Hz power frequency-ah chuan saturate turin 2,000 V kan mamawh a ni.

• 1 Hz test frequency (f hi a let 50 in a hniam zawk) ah chuan voltage a let 50 in kan mamawh tlem zawk: 2000V / 50=40 V!

 

A hnathawh dan:

• Analyzer hian 1 Hz emaw 0.1 Hz signal a inject → core chu < 40V ah a saturate → curve a teh → mathematically voltage chu 50 in a scale a, 50 Hz equivalent chu a plot thin.

 

Inquiry thawn rawh .
Inquiry thawn rawh .