Transformer efficiency leh rintlakna atana dielectric dissipation factor chanvo .

 Jul 03, 2024

 Message pakhat dah la .

 

Transformer oil dielectric dissipation factor hi thil pawimawh tak a ni a, chu chuan oil dinhmun leh transformer insulate theihna a lantir a ni. Dissipation factor, Tan Delta tia hriat bawk hi AC voltage-in energy dahkhawm a hman laiin energy hloh zat ratio tihna a ni a, unitless quantity anga tarlan a ni bawk.

A tlangpuiin, low dissipation factor chuan oil chu insulator tha tak a nih thu a tarlang a, a danglamna chu, dissipation factor sang tak chuan insulation system integrity tichhe thei thil bawlhhlawh, tui, emaw thil dang emaw a awm tih a tilang thei a ni. Chuvangin, dissipation factor enkawl hi transformer maintenance-a thil pawimawh tak a ni a, harsatna lian tham takah a lo chang hmain harsatna awm thei turte hriatchhuahna kawngah a pui thei a ni.

Transformer oil dissipation factor tehna atana hmanraw engemaw zat a awm a, chung zingah chuan oil-immersed electrode method leh partial discharge method te pawh a tel. Heng method pahnih hian high-voltage AC signal chu oil-ah hman a, a result current teh a ni a, chu chu dissipation factor chhut nan hman theih a ni.

Dissipation factor enkawl mai ni lovin, oil dinhmun pum pui tehna tur leh maintenance emaw replacement emaw a ngai em tih hriat nan oil analysis neih fo a pawimawh bawk. Hei hian tui awm zat, acidity, oxidation leh oil tichhe thei leh a hnathawh tichhe thei thil dang test te a huam thei a ni.

Huayi siam model YJS-H oil tan delta resistivity tester hi insulating oil ang chi liquid insulating medium-a dielectric loss factor leh DC resistivity tehna atan hman a ni. a inzawm tlat a ni. Internal integrated dielectric loss oil cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power supply, standard capacitor, high resistance meter, DC high voltage source, leh a bulpui ber dangte a ni. Instrument chhungah hian full digital technology, intelligent automatic measurement zawng zawng a hmang a, screen lian tak 5.7 inch TFT pure color LCD touch display a nei bawk a, test result chu automatic-in a dah thei a, a print chhuak thei bawk.

Transformer oil-a dielectric dissipation factor hi transformer rintlak leh him taka hman theihna tura parameter pawimawh tak a ni. He thil neih hi enfiah a, oil analysis mumal tak tih hian, maintenance personnel-te chuan thil awm thei turte hriatchhuahna kawngah an pui thei a, downtime leh hmanrua chhiatna man to tak a thlen hmain siamthatna tur hmalakna an nei thei bawk.

Inquiry thawn rawh .
Inquiry thawn rawh .