Power data logger hi power signal record atana siam a ni. Power generator test item te chu tester ah hian a inzawm khawm a. Chutiang test items hmang chuan Motor (Power Generator) NO-Load test, short circuit test, motor excitation step response test, motor excitatory de-excitation test, motor load rejection test, leh grid synchronous connection test te, leh on te pawh a awm thei ang.
Software components te hi curve analysis, math calculation, RMS calculation, power analysis, three-phase sequence analysis, frequency spectrum analysis, harmonic analysis, curve correlation analysis, picture editing vector sequence analysis leh a dangte siam nan hman theih a ni. Test data leh curve zawng zawng chu word/excel test report document-ah a chantir theih vek a ni. Tester huam chhunga curve zawng zawng chu JPG file-ah a chantir theih a, report siam belh zel turin PC-ah a save theih bawk.
Analog signal input channel 12 a awm a, binary signal input 12 a awm a, tester-ah hian relay contact output pathum a awm bawk. Tester sample rate sang ber chu 100kHz a ni. Power system test pangngai atana data record task zawng zawng deuhthaw chu a zo vek thei. Input channel zawng zawng chu pakhat leh pakhat atanga inhlat an nih avangin tester nena inzawm circuit hrang hrang zawng zawng chu an influence vek dawn lo.
Tester chhunga software system chak takah chuan data sample a awm a. Data Compression, Signal Statistics, leh Analysis, Curve Picture-Hmanrua siamna, Frequency Spectrum hmanrua, Curve Math hmanrua, Harmonic Analysis hmanrua, RMS chhiar dan, Power chhiar dan, Three{2}}Phase Signal Analysis Tool, leh Vector Analysis Tools. A nihna leh a thatna lian ber berte chu hetiang hian sawi theih a ni:
1 Recorded signal chu curve-ah scope hmangin tester-ah real-time-in a lang a. Multi-Curve analysis chu tester-ah hian a tel a. User te chuan sampled curves atang hian zoom in/out leh data location an nei thei.
2 Recorded curve te chu edit theih a ni a, text tag add theih a, a rawng a thlak theih a, a dang dang pawh a awm bawk. chutiang chuan users te chuan an duh zawk curve leh display mode ah report an siam thei ang.
3 Fourier transformer tools hian recorded curves amplitude leh phase spectrum a hmu thei a.
4 Curve zawng zawng chu X coordinate leh y coordinate atan thlan theih a ni a, chu curve pahnih inzawmna curve siam turin.
5 Harmonic tools te hian recorded curve atan harmonic vawi 1024 aia tam an hmu thei a ni.
6 Math tools hian scope chhunga curve eng pawh tan add, decrease, multiply, divide leh integration te a siam thei a.
7 User te chuan scope chhunga record curve eng pawh atan RMS, Power Watt calculation an siam thei.
8 Recorded pathum-phase voltage leh current signal te chu sequence, active power, reactive power, apparent power, power factor leh a dangte chhut nan hman theih a ni.
9 AC signal record zawng zawng atan vector group picture siam rawh.
10 Signal curve display mode chu software hmangin a set theih. Instantaneous curve emaw RMS curve pahnih hi tester hian a lantir thei a ni.
11 Motor NO{{1}Load test, short circuit test, excitation system step response test, de-excitation time constant tehna, frequency-voltage characteristic curve tehna. Load rejection test, leh grid synchronous connection test template te chu tester ah hian an inzawm khawm a. Chutiang template te test result chu record atan template hman a nih chuan automatic a ni ang.
12 Data leh result zawng zawng chu Word leh Excel Test Report-ah a chantir theih vek a ni.
13 Curve chu text automatic hmangin mark theih a ni. Chu chuan report siam chu a ti awlsam zawk .
14 Channel hming leh unit zawng zawng chu users ten an sawifiah leh thei.
15 Test configuration leh test setting zawng zawng chu a save vek ang.
16 Sensors setup window hian tester hian a value tak tak a lantir thei a, chu chu voltage sang, current sang, pressure sang, leh a dangte a ni a, chu chu user configure hnuah direct-in sensors factors te chu a configure a ni.
17 Data leh report zawng zawng chu U-disk ah save theih a ni. Chutiang chuan PC atanga report an review leh an siam theih nan.
18 Tester system disk-a protection unit chuan a reboot apiangin software leh system chu a recover thei a. Mahse test data zawng zawng chu save vek a ni ang.
1.2.2 Technique Index 1.1.
Tester-a technique index chu hetiang hi a ni.
1 Channel 12 voltage/current sample a awm a. Analog range-ah hian -10V~10V, -200V~200V, -400V~400V leh -20mA~20mA te a awm a ni. User te chuan software atang hian input range an switch thei a. Tin, channel pakhat -100mv~100mv a awm a, chu chuan input signal chu 10V aia tlem a phalsak bawk.
2 Voltage leh current input range assured errors chu hetiang hi a ni:
-400V~ 400V 0.5V aia tlem lo a dik lo tih a chiang.
-200V~ 200V 0.2V aia tlem lo a dik lo tih a chiang.
-10V~ 10V A dik e, 0.01V aia tlem a dik lo.
-20MA~ 20mA Error 0.02mA aia tlem lo a awm tih a chiang
-100MV~ 100MV 0.2MV aia tlem lo a awm tih a chiang.
3 Channel wet contacts binary signal input 12 a awm a. Input voltage dik leh phal chu DC12-200V a ni.
4 Channel relay contacts output 3 a awm. Contact-te tana capacity sang ber chu AC220V/1A a ni.
5 Data export leh mouse/keyboard input atana hman thin USB port 2 a awm a .
6 LCD chu 12.1 inches touchpad input mode a ni. Mihring interface chu a awlsam zawk nan siam rawh.
7 Tester chhunga hmun saved chu standard configuration atan 32G a ni.
8 Channel hrang hrang tan input resistance chu hetiang hi a ni:
-10V~10V Range Input laka inven theihna chu 820K a ni.
-200V~200V Range range input a awm theih dan chu 820K a ni.
-400V~400V range input a awm thei a, 820K a ni.
-20MA~20MA Range Input laka inven theihna 820K a ni.
-100MV~100MV Range range input laka inven theihna 10m a ni.
9 Power supply AC 220V 10% 45Hz-65Hz .