Transformer te hian electrical power transmission leh distribution-ah hmun pawimawh tak an chang a ni. Anni hian a tul angin voltage step up emaw, step down emaw an tum a, chu chu power chu hla tak takah leh consumer-te hnena tha taka thawn theih a nih theih nan a ni. Transformer rintlak leh himna tur atan transformer oil hi routine testing neih a pawimawh hle.
Transformer oil, insulating oil emaw dielectric oil tia hriat bawk hi coolant leh insulator angin a thawk a ni. Transformer hnathawh dan dik tak atan a pawimawh hle. Transformer oil hi routine testing hian harsatna lian tham a nih hmain thil awm thei te chu a hriat theih a, chu chuan transformer failure a thlen thei a ni.
Transformer oil-a test pawimawh tak tak eng emaw zat a awm a, chung zingah chuan:
1. Dissolved Gas Analysis (DGA) – DGA hi test pawimawh tak a ni a, transformer hnathawh avanga gas lo chhuakte awmna hriat theihna a ni. Heng gas te hian transformer chhunga fault emaw thil dang emaw awm leh awm loh a tilang thei a ni.
2. Moisture Content – Moisture hian transformer oil dielectric strength pumpui a tihhniam thei a, chu chuan arcing leh potential failure awm theihna a tipung thei a ni. Transformer chu him tak leh rintlak taka a thawh theih nan moisture content test hi a pawimawh hle.
3. Acid Number – Transformer oil acid number hian transformer tichhe thei, a dam rei zawng a tihtlem theihna tur corrosive compound awmna a tarlang thei a ni.
4. Interfacial tension – Interfacial tension tlahniam hi transformer oil-a bawlhhlawh awm leh awm loh hriattirna a ni thei a, chu chuan operational problem a thlen thei a ni.
5. Dielectric Breakdown Voltage – He test hian transformer oil hian electrical stress a tuar theih dan a teh a, a chhe lo thei lo. Dielectric breakdown voltage tihtlem hi bawlhhlawh emaw thil dang emaw a awm tih hriattirna a ni thei.
6. Oil Tan Delta Resistivity Test-Insulating oil ang chi liquid insulating medium-a dielectric loss factor leh DC resistivity tehna.
Test hi hun bi neia tih tur a ni tih hriat a pawimawh a, chu chu transformer kum leh a dinhmun leh oil hman chi hrang hrang a zirin a ni. Tin, hmanraw leh hmanraw dik tak hmanga technician thiam tak takte’n testing an neih theih nan a pawimawh bawk. Wuhan Huayi Electric Power Company chuan a mamawh phuhrukna tur oil test hmanrua series chu a zirchiang a, a siam chhuak a ni, tiin IEC Standard chuan a tarlang. Transformer oil parameters test leh analysis an nei thei a, transformer te performance an vawng reng thei bawk.