Testing leh measurement device te hi substation chhunga electrical component te rintlak, himna leh an hnathawh that theihna tura hmanraw pawimawh tak a ni. Test leh maintenance tih fo hian a tir lamah harsatna awm thei te hriatchhuah a pui a, hmanrua a chhiat loh nan leh downtime a tih tlem theih nan a pui bawk. Heng hmanrua te hian routine maintenance, diagnostics, leh troubleshooting-ah te hmun pawimawh tak an chang a ni.
1. Voltage leh current tehna hmanrua:
· Digital multimeters:
· Digital multimeter hmangin electrical circuit-a voltage, current leh resistance te an teh thin.
· Electrical components te chu a tha taka an thawh theih nan routine check leh troubleshooting atan an pawimawh hle.
2. Power quality analyzer te:
· Harmonic leh voltage inthlak danglamna:
· Power quality analyzer te hian harmonics, voltage inthlak danglam dan, leh power factor te tehna hmangin electrical power quality an teh thin.
· Power supply rintlakna tichhe thei tur thil hriatchhuah leh hmachhawn an pui thin.
3. Cable Fault Locators:
· Cable fault hriat theihna:
· Cable fault locators hmang hian lei hnuaia cable-a fault awmna hmun hriat theih a ni.
· Cable fault awmna dik tak chu siamthatna tha tak leh downtime tlemte chauh a awm theih nan an puih theih nan an pui thin.
4. Insulation laka inven theihna testers:
· Insulation system hrang hrangte dikna:
· Insulation resistance testers te hian electrical components ah insulation an do theih dan an teh thin. Heng test te hian insulation system te integrity a tichiang a, electrical leakage leh breakdown te venna kawngah a pui bawk.
5. A then atanga a chhuahna tur hriat theihna: 1.1.
· Insulation chungchanga thil awm dan hriat hmasak dan:
· Partial discharge detector te hian insulation system chhunga partial discharge te an hmuchhuak thin.
· Partial discharge hmuh hmasak hian insulation breakdown a veng a, electrical components te dam chhung a ti rei bawk.
6. Transformer hian ratio testers a turn a:
· Transformer winding ratio te tehna:
· Transformer turns ratio testers te chuan transformer windings turns ratio an teh thin.
· He test hi transformer te chu voltage level dik taka an thawh theihna tur leh transformer windings-a harsatna awm thei te hriatchhuahna atan a pawimawh hle.
7. Circuit breaker analysters:
· Circuit breaker te performance test dan:
· Circuit breaker analyzer te hian circuit breaker te hnathawh dan an zir chiang thin.
· Heng device te hian circuit breaker te hun, hman dan leh an dinhmun te chu fault awm laiin dik taka an chhan theih nan an finfiah thin.
8. Relay test set hrang hrang:
· Protection relays te finfiah dan:
· Relay test set hmangin protection relay te hnathawh dan tur an enfiah thin.
· Testing tih fo hian relay-te chuan dinhmun pangngai lo tak takte chu dik taka an chhan theih nan a enkawl a, substation atan venhimna rintlak tak a pe a ni.
9. High-Thil awm thei (hipot testers) nei thei:
· Dielectric chakna hmanga test dan:
· High-potential testers te chuan insulation dielectric strength chu voltage sang zawk-tha zawk-sawi hmangin an teh thin.
· He test hian insulation system-a chak lohna awm thei turte hriatchhuah a pui a ni.
10. Lei lama dodaltu testers: 1.1.
· Grounding hman tangkai dan tehna: 1.1.
· Ground resistance testers te hian grounding system te resistance an teh thin.
· Safety leh equipment venhimna atan grounding dik tak neih a pawimawh a, heng test te hian grounding system te chu a tha hle tih a tichiang a ni.
11. Voltage detector leh phasing hmanrua te:
· High-Voltage hnathawh tur himna hmanrua:
· High-voltage hmanrua hmanga hnathawktute himna tur atan voltage detector leh phasing tools te hi a pawimawh hle. Voltage awm lohna finfiah nan an pui a, phase relationship an hriat theih nan an pui bawk.
12. Battery test tu:
· Battery hriselna chungchanga tehna: 1.1.
· Battery testers te hian backup power atana hman thin battery te hriselna leh an theihna an teh thin.
· Test mumal tak neih hian power outage laiin battery rintlak a awm theih nan a enkawl thin.
13. Frequency chhanna thlirletna: 1.1.
· Frequency-Thil test a innghat a ni:
· Frequency response analyzer te hian frequency-electrical components te ziarang a innghat tih an zirchiang thin.
· Frequency condition hrang hrang hnuaia device awm dan tehna atan an tangkai hle.
14. Oil test-na hmanrua:
· Dissolved Gas Analysis (DGA) leh Oil Quality Testing te:
· Oil testing hmanrua hian transformer oil quality a zirchiang a, dissolved gas analysis (DGA) a ti bawk.
· Heng test te hian transformer dinhmun tehna leh harsatna awm thei te hriatchhuahna kawngah a pui thin.
15. Switchgear voltage sang tak test na : 1.1.
· High-Substation switchgear-a Voltage testing hi hmanrua rintlak leh himna tur atana hmalakna pawimawh tak a ni