Terminology partial discharge tehna hmanruaa hman tlanglawn .

 May 15, 2023

 Message pakhat dah la .

 

1. A then a chhuah .
Partial discharge tih hian insulation awmna hmuna discharge a kawk a, chu chu insulation pumpui penetrating breakdown a ni lo. Discharge form pathum a awm a, chungte chu internal discharge (medium chhungah), creeping discharge (medium chunglamah), leh corona discharge (electrode tip-ah) te a awm a ni.
2. Charge quantity Q 1000 a ni.
Instantaneously inject a, test object tawp pahnihah charge zat engemaw zat inject la, chutiang chuan test object-a terminal voltage inthlak danglamna chu partial discharge avanga terminal voltage inthlak danglamna nen a inang ang. He injected amount hi partial discharge charge apparent charge a ni.
3. A lan dan chuan a chhuak calibrator .
A lan dan chuan discharge calibrator hi standard electricity generator a ni. Test hmain electric a zat tur ruat sa a output a, sample tawp ber pahnihah a dah a, chu chu he electric zat hnuaia sample chhuah a nih hunah partial discharge tester chhanna simulate a ni. Hetih lai hian scale coefficient chu siamrem rawh. Test neih chhunga rated voltage hnuaia sample discharge apparent discharge tehna tur partial discharge detector range chu teh rawh. Discharge capacity chu standard power generator nena khaikhin chuan indirect-a teh a nih avangin, direct-a teh ai chuan discharge capacity chu "apparent discharge capacity" an ti a ni.
Calibration power generator hi partial discharge tehna atana hmanraw pawimawh tak a ni a, a performance parameters te hi test result dik leh dik loh nen a inzawm tlat a ni.
Apparent discharge calibrator hi calibration pulse voltage generator leh calibration capacitor series-a siam a ni a, a parameter-te chu: pulse waveform rise time, decay time, internal resistance, pulse peak value, calibration capacitor value, etc. te a ni.
Calibration pulse voltage generator voltage waveform rise time chu 0.1U0 atanga 0.9U0 thlenga hun a ni a, decay time chu peak value atanga 0.1U0 thlenga hun a ni.
4. Detection impedance .
Detection impedance hi detection signal lakna hmanrua a ni. A hmannaah chuan, detection impedance dik tak chu test tum hrang hrang leh test object chi hrang hrang angin thlan tur a ni a, chutiang chuan sensitivity, resolution, waveform characteristics leh signal-to-noise ratio of partial discharge measurement tihsan theih a ni.
5. Hun hman dan (Gate Unit) .
Time window hi circuit device a ni a, interference signal lian zawk, peak detection circuit-a partial discharge lut tur venna atana siam a ni. A chhan chu interference engemaw zat chu test tak takah a rawn luh tir ngei ang, a bik takin field test-ah chuan time window hman a pawimawh zawk.
Time window-a hnathawh dan tur chu elliptical scanning time base chu hmun hnih-ah then a ni a, conduction (highlighted area) leh cut-off (non-highlighted area), leh discharge pulse chu conduction (highlighted area)-ah dahin time window awmna leh a zau zawng a inthlak a ni. , interference pulse chu cut-off (unhighlighted area)-ah dah a ni a, tun dinhmunah chuan meter chhiar chu discharge pulse value a ni a, interference hian a lian leh te pawh nise discharge pulse value a nghawng dawn lo. Time window pahnih chu a ruala khar a nih chuan meter reading chu ellipse pumpui a pulse peak value a ni.