Solar Module IV Tester chu xenon lamp hmanga test atana ni êng simulate tur a ni a, solar cell module test mamawh power, efficiency, voltage, current leh parameter dangte neih theih nan a ni. Test system-a principle bulpui ber chu ni hian solar cell components test mek chunga illumination a simulate hian electric load hmangin solar cell components-a current inthlak danglamna chu control a ni a, volt-a voltage leh current te chu components-a voltage leh current te chu teh a ni.
Performance ziarang .
u Irradiance Inhomogeneity: Grade A chuan tehna nghet tak a neih theih nan.
u Power detection error: < ± 1%, small leh medium -sized manufacturer te mamawh phuhruk nan
u Quick On-Duty Operation: On-Site training of operators, minute 30 chhungin duty operation
u FLoating Frame Display: The Test Software Real-Time Monitoring, Component Measurement parameters-in design mamawh a tlin loh chuan software chuan alarm a tidik nghal a, operator-te tana technical requirement a tihtlem phah a ni.
|
Product Model 1000 a ni. |
HYZG100 a ni. |
|
Process Parameters te chu . |
|
|
Productivity 1.1. |
<5S/PCS 1000 a ni. |
|
Test na hmun . |
2,000mm*1,000mm a ni. |
|
light source lam hawi a ni . |
Light source hian light downward a pe chhuak thin . |
|
Automation mode a ni a, a hman dan pawh a inang lo hle. |
Manual / sem dan line . |
|
A tehna parameters . |
|
|
Eng chhuahna hmun . |
HID(high intensity discharge lamp) . |
|
spectrum 100 a ni. |
-- |
|
Light Source Class 1000 a ni. |
-- |
|
A kalpui dan tur tehfung . |
-- |
|
Calibration hman dan . |
-- |
|
Spectral match 100 a ni. |
-- |
|
A tawi-Term instability (STI) . |
-- |
|
Long-Term instability (LTI) 1.1. |
-- |
|
Non-Irradiance a awm dan inang lo . |
<2%(grade A ) . |
|
Spectral range a ni a. |
400-1100nm a ni. |
|
Irradiance hun hman dan . |
15ms a ni. |
|
intensity range a ni. |
1000W / m² |
|
Repetition dikzia . |
<±1% |
|
Xenon Lamp nun . |
admidia 15W a ni tawh. |
|
Voltage 1000 a ni. |
0-80V (resolution 1MV) a ni. |
|
current range . |
0-20A (Resolution 1ma) a ni. |
|
Solar Cell Parameter Analytics 1000 a awm a. |
A rilru a buai em em a, a rilru a hah em em bawk a. |
|
Product dimension leh mamawh . |
|
|
System control a ni a . |
Integrated PC hian application software a run a, hardware a control bawk. |
|
User interface 1000 a ni. |
Touch screen, keyboard leh mouse te a awm bawk. |
|
Chenna khawvel |
Non-Condensing ambient humidity leh relative humidity 85% aia tlem lo |
|
A chhehvel boruak lum leh vawt . |
25℃± 10℃a ni. |
|
Thuneihna |
AC220V/50Hz/10A ah hian a awm a. |
|
Thil hmanrua dimensions . |
1600mm*2450mm*830mm a ni. |