1. Circuit breaker te: 1.1.
· High-Voltage circuit breaker te:
· High-Voltage circuit breaker te hi fault emaw abnormal condition emaw a awm chuan electrical current titawp emaw ti chhe emaw thei tur venna hmanrua pawimawh tak an ni. Power system-a section dik lo tak takte isolate-naah te, hmanrua tihchhiat loh nan leh downtime tih tlem nan te hmun pawimawh tak an chang a ni.
· Circuit breaker chi hrang hrang:
· Circuit breaker chi hrang hrang zingah hian air circuit breaker, vacuum circuit breaker, leh gas-insulated circuit breaker te a awm a. Type thlan dan hi voltage level, application mamawh, leh environment ngaihtuah dan ang chi thilteah a innghat a ni.
2. Relays: 1.1.
· Hriselna atana hman tur relay te: 1.1.
· Protection relays chu electrical parameter leh trip enkawlna hmanrua a ni.
Circuit breaker emaw, venhimna hmanrua dang emaw a awm loh chuan a awm loh chuan. Protection relay chi hrang hrang hman tlanglawn tak takte chu overcurrent relay, differential relay, distance relay, leh directional relay te an ni. Microprocessor-based relays: Tunlai protective relay-ah chuan microprocessor-based technology an hmang fo va, substation venhimna tihchangtlunna atan feature hmasawn tak tak, flexibility, leh communication theihna an pe fo thin.
3. Invenna leh enkawlna system: 1.1.
· Substation Automation Systems (SAS):
· SAS hian substation hnathawh awlsam taka kalpui theihna tur leh venhimna, control, leh monitoring tihchangtlunna turin protective relay, control system, leh communication network te a thlunzawm a ni.
theihna (capabilities) te.
· Heng system te hian faults te, real-time data analysis te, leh substation hmanrua te remote control te chu rang taka chhanna a pe thei a ni.
4. Ground fault detectors: 1.1.
Ground fault detectors chuan electrical system-a ground fault awm chu a hre thei a, .
a dik lo section isolate turin protective action trigger. Heng hmanrua te hi electric shock hlauhawm lo awm tur venna leh hmanrua chhiatna tihtlem nan a pawimawh hle.
5. Over-Tunlai venhimna hmanrua:
· Over-Tunlai relay-te chu:
· Over-Tunlai venna hmanrua, over-Tunlai relay ang chi te hian a tam lutuk tih a hmuchhuak
System chhunga current flow leh protective action intan tir. Thil hmanrua a chhiat loh nan an pui a, thermal overloads laka an him loh nan an pui bawk.
6. Transformer laka invenna hmanrua:
· Buchholz Relay-ah hian a awm a.
· Buchholz relay hi transformer humhalh nan hman a ni tlangpui. Chumi
Internal faults, insulation breakdown emaw, awm emaw ang chi te a hmuchhuak thin.
gas kang thei a ni.
Fault a awm tih hmuhchhuah a nih chuan Buchholz relay chuan transformer trip turin signal a thawn a, .
Thil chhiat belh zel tur venna.
7. Voltage laka invenna hmanrua:
·-Voltage leh over-Voltage relays:
· Under-voltage leh over-Voltage relay te hian system chhunga voltage level awm dan an enfiah thin. Anni hian voltage a tlak emaw, predefined limits aia tam a nih chuan protective devices an trip a, chu chuan hmanrua a chhiat loh nan a veng thei a ni.
8. Frequency laka invenna hmanrua:
· Frequency relay te: 1.1.
· Frequency Relays Electrical system a frequency enfiah thin. Normal frequency atanga inthlak danglamna hian thil awm thei a kawk thei a, relay hian system stability vawng reng turin protective action a tichhuak thei bawk.
9. Arc flash hmuhchhuah dan tur:
· Arc flash sensor te chu:
· ARC Flash Detection Systems Sensor hmangin arc flash event lo awm dan hriat theih a ni a, hei hi energy chhuahna hlauhawm tak a ni. Heng systems te hian rang takin trip circuit breakers 2019 tih tlem nan .
of arc flash incidents, mi leh hmanrua humhalh.
10. Surge mantute: 1.1.
· Lightning leh surge laka invenna:
· Surge arresters te hian lightning strike emaw switching operation emaw avanga voltage surge lo awm tur lakah an venghim thin.
· Energy tam zawk chu leiah an divert a, chu chuan hmanraw sensitive tak tak leh insulation a chhiat loh nan a pui a ni.
11. Fault locators:
· Fault awmna hmun hriat theihna hmanrua:
· Fault locators hmangin electrical system-a fault awmna hmun hriat theih a ni a, targeted repairs siam awlsam leh downtime tih tlem a ni.
12. Gas enkawlna hmanrua:
· Gas hriat theihna tur: 1.1.
· Gas monitoring device te hi gas-insulated substations ah hian insulating gas leak awm leh awm loh hriat theih nan an hmang thin. Gas leak hmuh hmasak hian hmanrua a chhiat loh nan a pui a, mipui himna a tichiang bawk.
Protective devices hi transmission line infrastructure-a thil pawimawh tak a ni a, electrical fault leh disturbances laka venhimna pawimawh tak a pe a ni. Thil hmanrua, mi leh sate, leh power system-a a dikna zawng zawng humhalhna kawnga an that leh that loh enfiah turin venhimna hmanrua te chu a inmil dan tur, test leh enkawl dan tur dik tak neih a ngai a ni.