1. Multi-Channel tehna: Voltage channel 4 leh current channel 4 chu a rualin teh a ni.
2. Electrical parameter tehna: A rualin voltage amplitude, current amplitude, phase, frequency, active power, reactive power, power factor, leh parameter dangte a teh thei a
3. 2-64th voltage harmonic leh current harmonic content a teh thei a;
4. Inter harmonic content chu 0.5-31.5 times voltage leh current a teh thei a;
5. voltage leh current-a harmonic distortion rate zawng zawng a teh thei a;
6. Short-Term Flicker (PST), Long-Term Flicker (PLT), leh voltage inthlak danglamna te a teh thei a;
7. positive sequence voltage, negative sequence voltage, zero sequence voltage, leh voltage imbalance te a teh thei a;
8. positive sequence current, negative sequence current, zero sequence current, leh current imbalance te a teh thei a;
9. Transient parameter measurement function, recording voltage sudden rise leh fall events hnathawh dan nen, leh thil thleng hun chhung leh a hma leh hnua cycle pangate waveform tak tak record turin wave recording function chu automatic-in a start a
10. Oscilloscope function a nei a, chu chuan voltage leh current magnitude leh distortion chu real-time waveforms-ah a lantir thei a, instrument-a voltage leh current waveforms te chu a scale thei bawk Waveform factor chhiar dan a nei a;
11. Hexagonal diagram display function hian metering loop leh protection device loop te vector analysis a ti thei a, metering devices wiring dik lo a awm leh awm loh a enfiah thei bawk Pathum-phase pathum-wire wiring mode-ah chuan wiring mode 48 chu automatic-in a hriat theih a; Supplementary power hmanga automatic calculation function hi hman a awlsam hle. Personnel te chuan wiring problem nei te tan power additional an chhut ang.
12. Optional large clamp meter hmang hian low-voltage current transformer te transformation ratio leh angle danglamna tehna hman theih a ni a;
13. Harmonic content chu bar graph angin visual effect tha tak tak hmangin a lang thei a;
14. Built- lian takah-Capacity data storage, (Storage interval 1 second - 1000 optional) chu thla 18 aia tam minute 1 chhungin dah chhunzawm theih a ni a
15. 10-inch lian-screen rawng LCD monitor 1280×800;
16. Capacitive screen touch operation hi tablet computer leh smartphone hman dan nen a inang a, zir a awlsam bawk;
17. Mouse hnathawh dan tur thlawp a, thil tih dan hrang hrang nei operator-te nena inmil;
18. Harmonics tehnaah chuan order tinte harmonic content chu national standard angin standard aia tam a nih leh nih loh chu automatic-in a hriat theih a, prompt a pe thei a, chu chu a mitmengah a chiang a
19. Harmonic content rate national standard query function chuan national standard allowable value te chu a zawt thei a;
20. Frequency measurement range 42.5Hz-69Hz a nei a, power system 50 leh 60 a teh thei bawk.
21. Data hi USB flash drive ah hian historical query atan dah theih a ni.
22. Test result thlirlet leh process turin special data analysis leh management software te pawh a awm thei. Power quality leh load periodic changes of the measured points te chu a man thei a ni. Power worker-te tan chuan user-te power quality an hriatthiam a, a inmil tur processing measures an lak chu thlak theih a ni lo. thiltih;
23. Analysis software hian ram pum huap standard angin professional power quality analysis report a siam thei a;
24. Instrument hian screen capture function a nei a, screen eng pawha display data chu thlalak angin kut hmanga save theih a ni a;
25. Instrument hi a lian lo hle a, a rit lam a rit a, a phur awlsam bawk;
26. Built-Performance Lithium-ION Battery chu Power-saving mode-ah automatic-in a lut a, chu chuan instrument chu pawn lam power supply tel lovin darkar 10 aia rei hna a thawk chhunzawm thei a, chu chuan on-site testing atan a remchang a ni