Electrical substation atana enfiah leh enkawlna hmanrua .

 May 31, 2024

 Message pakhat dah la .

 

Inspection leh maintenance equipment "Electrical substation pakhata component hrang hranga a dinhmun tehna, enfiahna leh enkawlna hna thawhna atana hmanrua, hmanrua, leh machinery hmante a huam a ni. He hmanrua hi substation infrastructure rintlak, himna leh hnathawh thatna tur atana pawimawh tak a ni. Here’s an elaboration of key aspects related with inspection and maintenance of equipment in the context of AIS & GISSation:

 

1. Hriselna hmanrua:

· Mimal invenna hmanrua (PPE):

· Inspection leh maintenance neih chhung hian himna hi ngaih pawimawh ber a ni. PPE, hard hats, safety glasses, safety shoes, gloves, leh incheina tur dik tak te hi a pawimawh a, chu chuan mi te chu hlauhawm lo thei laka an him theih nan a pawimawh hle.

· Hnathawktute tan himna tur harness leh fall protection equipment te a ngai thei ang.

A san zawng te.

2. Diagnostic hmanrua:

· A then atanga a chhuah theihna tur detector: 1.1.

· Heng detector te hian electrical insulation-a partial discharge te an hmuchhuak a, chu chuan equipment failure a thlen hmain insulation breakdown awm thei te chu a hriat theih nan a pui a ni .

3. Electrical test-na hmanrua: 1.1.

· Voltage test tu te:

· Voltage testers hmangin electrical 1000 ah voltage awm leh awm loh an enfiah thin.

Components, hmanrua chu de-in enkawl hna thawh tan hmain tihchak a nih theih nan enfiah.

· Insulation do thei lo testers:

· Heng testers te hian electrical components te insulation resistance an teh a, chu chuan insulation system te integrity a teh thin.

· Circuit breaker analyser te chu:

· Circuit breaker analyzer te hi circuit breaker te hnathawh dan test leh analysis atan hman a ni a, fault condition laiin an hnathawh dan tur dik tak an enfiah thin.

4. Mechanical enfiahna hmanrua: 1.1.

· Torque-a a chet dan:

· Torque wrench hmang hian bolt leh connection tihkhauh laiin torque value bik hman a ni a, hei hian mechanical integrity dik tak a siam thei a ni.

5. Oil test dan tur:

Dissolved Gas Analysis (DGA) hmanrua:

· DGA hmanrua hmangin transformer oil-a gas awmte chu an zirchiang a. Gas level inthlak danglamna hian transformer chhunga chhiatna awm thei emaw, thil awm thei lo emaw a awm tih a tilang thei a ni.

Oil sampling kits te chu:

· Oil sampling kits hi laboratory analysis atana oil sample lakkhawmna atan hman a ni a, transformer insulation dinhmun hriat theihna leh harsatna awm thei te hriatchhuah a ni.

6. Condition enkawl dan tur: 1.1.

· Online-a enfiahna kalphung: 1.1.

· Continuous monitoring systems hian critical substation components dinhmun chungchanga time data tak tak a pe a, hei hian proactive maintenance a siam thei a, beisei loh taka hlawhchhamna a thlen thei bawk.

· Heng system te hian sensor, communication module, leh data analysis te a huam thei .

software.

7. Cable test dan tur:

· Cable fault locators:

· Cable fault locators hian lei hnuaia cable-a fault awmna hmun hriat theihna a pui a, targeted repairs leh downtime tih tlem theih a ni.

· Cable diagnostic system hrang hrangte:

· Heng system te hian power cable dinhmun chu insulation resistance, capacitance, leh partial discharge te tehna hmangin an teh thin.

8. Grounding leh bonding test tu te:

·

Leilung dodaltu testers: 1.1.

Ground resistance testers te chuan grounding system te resistance an teh a, substation grounding chu himna leh hmanrua venhimna atana pawm theih chin chhungah a awm tih an tichiang a ni.

· Bonding test tu te:

· Bonding Testers Bonding connection-te integrity an teh a, electrical equipment chu stray currents venna tur leh grounding dik tak neih theihna tura a tha taka bonded a nih leh nih loh finfiah a ni.

Inspection leh maintenance hmanrua te hian AIS substation rintlak leh himna tur atan hmun pawimawh tak an chang a ni. Inspection leh proactive maintenance hmalakna, hmanraw leh hmanrua \\ha tak takte \\anpuina hian substation infrastructure dam rei leh \\ha ber a thlen \\hin.

Inquiry thawn rawh .
Inquiry thawn rawh .