Power atana cable thlan dan .

 Apr 28, 2024

 Message pakhat dah la .

 

Power transmission atana cable remchang ber thlan chu electrical system chu a tha leh him taka a thawh theih nan a pawimawh hle. Cable thlan hunah ngaihtuah tur pawimawh engemaw zat a awm. Chung zingah chuan operating voltage, operating frequency, insulation level, cross{2}}section area (MM2), conductor type, core number, neutral leh earthing cable, leh derating factors te a tel.

Factor ngaihtuah hmasak ber chu operating voltage a ni. Hei hi cable hnathawh tur voltage a ni a, system voltage atana rated cable thlan a pawimawh hle. Voltage rating chu system voltage sang ber nen a inang tur a ni.

A dawttu chu operating frequency a ni. Hei hi cable-in power a phur tur frequency a ni a, cable performance-ah pawh nghawng a nei thei a ni. Cable chi hrang hrang hi frequency hrang hrang atan siam a nih avangin system frequency atan cable dik tak thlan a pawimawh hle.

Power atana cable thlan hunah pawh insulation level ngaihtuah a pawimawh hle. Cable-a insulation rating chu system-a voltage rating nen a inang tur a ni. Hei hian cable hian electrical arcing emaw breakdown emaw hlauhawm lovin power him taka a phurh theih nan a pui ang.

Cable-a cross-section area (mm2) pawh ngaihtuah tel a ngai bawk. Cross-Section area hian cable carrying capacity awm mek chu a tichiang a. Cable chu a chhunga current luang chhuak tur maximum current chu a handle theih nan size tur a ni. Current load atana cable te lutuk chu a lum lutuk thei a, kangmei hlauhawm a ni thei bawk.

Conductor type tih hian cable-a conductive element atana hman tur material a kawk a ni. Conductor chi hrang hrang hman tlanglawn ber chu copper leh aluminum te an ni. Copper hi conductivity sang tak neia hriat a ni a, aluminum erawh a man tlawm zawk a, a rit zawk bawk. Conductor type thlan dan hi thil engemaw zat a innghat a, chu chu cable run hlat zawng, voltage level, leh load mamawh te a ni.

Core number hian cable chhunga conductor awm zat a kawk a ni. Common core number tam ber chu single-core, pahnih-core, leh pathum-core te an ni. Single-core cable hi high-voltage power transmission atan hman a ni a, voltage level hniam zawk atan chuan pahnih leh pathum-core cable hi hman a ni thung. Core number dik tak thlan chu power mamawh, voltage level leh phase hrang hrang awm zat a zirin a innghat a ni.

Neutral leh earthing cable te hi safe power transmission atan a pawimawh hle. Neutral cable hian current tan return path a pe a, earthing cable erawh chuan system chu voltage leh current tam lutuk lakah a veng thung. Neutral leh earthing cable chi hrang hrang mamawh chu system-a voltage level, earthing system hman chi leh fault protection hman danah a innghat ang.

Derating factors tih hian environment leh installation dinhmun a zirin cable-in a phurh theihna tur a siamrem dan a kawk a ni. Ambient temperature sang, lei hnuaia dah, leh cable bundling te hian cable hnathawh temperature a nghawng thei a, chutiang chuan a current-carrying capacity a nghawng thei bawk. Cable chu him taka leh a design limit chhunga a thawh theih nan derating factors chungchangah cable size thlan a pawimawh hle.

Inquiry thawn rawh .