Tuna transformer (CT) nameplate chhiar leh hriatthiam dan .

 Sep 12, 2025

 Message pakhat dah la .

 

Tuna transformer (CT) nameplate hman mek hi engtin nge kan chhiar ang a, kan hriatthiam ang?

Current transformer (CT) chuan high current (KA level) chu a hlutna te tak te, teh theih (1 a emaw 5 a emaw)-ah a hruai thla a ni. Hei hian meter, relay, leh venhimna hmanrua te him taka inzawmna a siam thei a ni. Current transformer (CTs) te hi electrical system-a current flow tehna leh enkawlna atana thil pawimawh tak an ni. CT nameplate-a thu awmte chhiar leh hrilhfiah dan hriatthiam hi device-a dah leh hman dan dik tak hriat chian nan a pawimawh hle. CT nameplate dik taka chhiar hian metering dik tak, venhimna rintlak tak, leh electrical network him taka hman theihna tur a siam a ni.


A tlangpuiin CT nameplate data sawifiah a ni.

CT ratio (primary / secondary current) .
Entirnan: 1000/5 A tih ang chi te hi a ni.
A awmzia: Primary-a A 1000 a luang chuan 5 A chu secondary-ah a awm ang.
phurrit (VA) .
Entirnan: 15 VA .
Load CT tam ber chuan a supply thei (meter + relay + cable resistance).
He → Accuracy a tlahniam.
Accuracy class 1000 a ni.
0.2 / 0.5 / 1 → CT metering (a dikna sang, bill, tehna).
5P / 10P / PS → Protection CT (fault current laiin a thawk dik).

Knee point voltage (VK) (protection CTS chauh) a awm bawk.
voltage a CT a saturates. Differential protection atana pawimawh.
ALF (accuracy limit factor) (protection CTS) 1.1.
Entirnan: ALF 10 → CT chu 10 × rated current thlengin a dik reng a ni.
ILF (instrument limit factor) (metering CTS) 1.1.
Entirnan: ILF 5 → Current chu 5 × rated value aia sang a nih chuan meter a venghim.
Rated continuous current (IN) .
CT hian he current hi overheating awm lovin a phur chhunzawm thei a ni.
Entirnan: Rated current atanga 120%.
Short-Hun thermal current (ITH) .
Fault withstand current chu 1s emaw 3s emaw atan a ni.
Entirnan: ith=25 Ka / 1s.
Dynamic current (IDYN) 1.1.
Short circuit (a tlangpuiin 2.5 × ith) laiin mechanical withstand a ni.
Frequency & Standard .


Entirnan: 50 Hz, IEC 61869 / chu 2705 a ni.

Entirna CT nameplate tih a ni.
CT ratio: 1000/5 A a ni.
A phurrit: 15 VA .
A dikna class: 0.5 (metering), 5p10 (protection) a ni.
A khup point: 100 v a ni.
ALF: 10 a ni.
ILF: 5 a ni.
Ith: 25 Ka / 1s
IDYN: 62.5 ka ti a.
Rated Continuous Current: 120%
A thlen tam dan: 50 Hz
Standard: IEC 61869 a ni.

 

CT nameplate chhiar leh hrilhfiah dan hriatthiam hi CT model dik thlan nan te, current tehna dik tak neih theihna tur leh electrical system rintlakna vawng reng tur atan te a pawimawh hle. Primary leh secondary ratings, accuracy class, burden rating, frequency, leh temperature ratings te ang chi key parameters te ngaihven a nih chuan i application-a CTS i thlan leh install hunah thutlukna dik tak i siam thei ang. CT nameplate chhiar chungchanga zawhna emaw, ngaihtuahna emaw i neih chuan, a siamtu emaw, electrical professional thiam tak emaw hnenah kaihhruaina dil fo ang che.

Inquiry thawn rawh .
Inquiry thawn rawh .