Transformer oil a dielectric strength tih that dan tur .

 Mar 21, 2025

 Message pakhat dah la .

 

Transformer oil-a dielectric strength tihchangtlun hi transformer him taka hman theihna tura tehfung pawimawh tak a ni. A hnuaia methods te hian transformer oil insulation property siam that nan a pui thei che a ni.

1. Oil atanga tui lakchhuah .
Thiltih dan: Vacuum oil filter emaw heating dehydration hmanrua emaw hmangin oil chhunga tui awm emaw, tui awm lo emaw chu paih chhuah theih a ni.
A chhan: Moisture hi dielectric strength tihtlem chhan ber a ni a, chu chuan conductive channel a siam ang a, chu chuan breakdown a thlen ang.
Thurawn: Oil-a tui awm zat chu standard value aia hniam (a tlangpuiin 35 ppm aia tlem emaw, a tlukpui emaw) a nih leh nih loh enfiah fo thin ang che.
2. Filter bawlhhlawh te .
Thiltih dan: Oil chhunga solid particle, fiber leh bawlhhlawh dangte chu precision oil filter hmanrua hmangin an paih chhuak a.
A chhan: Thil bawlhhlawh hian tualchhung electric field concentration a siam ang a, oil-a insulation performance a ti tlem ang.
Thurawn: Transformer enkawl emaw oil thlak emaw lai hian secondary contamination awm loh nan fuel tank leh internal components te chu uluk takin tifai thin ang che.

3. Oil aging venna .
Thiltih dan: Antioxidant chu oil aging rate tih hniam nan an dah a. A lum lutuk loh nan operating temperature control a ni.
A chhan: Tarna hian oil chhunga acidic substance leh sediment siam a thlen ang a, dielectric strength a ti tlem ang.
Thurawn: Oil-a acid value leh oxidation stability chu enfiah fo la, a hun takah oil upa tawh tak chu thlak leh rawh.
4. Test leh enkawl reng reng .
Thiltih dan: Dielectric strength test hi IEC 60156 emaw ASTM D877 ang chi standard angin tih thin a ni.
A chhan: A hun taka harsatna awm chu zawng la, targeted measures la rawh.
Thurawn: Test result leh oil quality trend record turin oil quality monitoring file siam.

5. High-Quality transformer oil 1000 thlang rawh.
Thiltih dan: Standard nena inmil tur high- quality transformer oil thlang la, chu chu Class I emaw Class II oil emaw ang chi hi a ni.
A chhan: High-Quality oils hian insulation property leh oxidation resistance tha zawk a nei a.
Thurawn: A lei lai khan a dielectric strength, moisture content, leh indicator dangte’n standard an tlin theih nan oil enfiahna report dil rawh.
6. Operating environment control .
Thiltih dan: Pawn lam bawlhhlawh a luh loh nan transformer operating environment chu a vawt leh fai taka dah tur a ni.
A chhan: Environment humidity leh pollutants hian oil insulation performance a nghawng thei a ni.
Suggestion: Fuel tank leh respirator te a thawk tha em tih enfiah nan transformer tightness te chu a hun hunah enfiah thin ang che.

Inquiry thawn rawh .
Inquiry thawn rawh .