Turn Ratio tehna tih dan .

 Jul 15, 2024

 Message pakhat dah la .

 

Turn ratio tehna hi kawng hrang hrang pahnih hmangin siam theih a ni a;
ani. Bridge hman dan tur .
b. Windings te voltage ratio tehna hmangin .
Turn ratio tehna chu a innghat a, bridge (equipment) hmanga winding pakhatah phase voltage hman a, bridge-a induced voltage ratio tehna a ni. Measurement te chu phase zawng zawngah leh tap position zawng zawngah repeat a ni a, a hnungzuiin. Measurement lai hian magnetic flux inang nei winding couple te turn ratio chauh teh theih a ni a, chu chu 1000 a ni tihna a ni.
Vector diagram-a parallel vector nei winding couple zingah turn ratio teh theih a ni.
Theoretical Turn Ratio=HV winding voltage / LV winding voltage theoretical NO-Load Turn Ratio chu hmanruaah adjustable transformer hmangin a inthlak a, % error indicator-a balance a awm hma loh chuan a danglam a ni. He error chungchanga value chhiar .
Indicator ah hian transformer a deviaton te chu real turn ratio atanga % anga tarlan a ni.
info-583-80
Winding couple-a voltage teh tur chu a rualin teh theih a ni a, ratio pawh hriat theih a ni a, a nih loh leh chutiang atana siam digital instruments chu voltage ratio tehna method-ah hman theih a ni bawk. Chutiang instruments hmangin, turn ratio tehna bakah, connection group (three-phase measuring instrument hmanga siam) leh tehna
Measurement neih chhunga current te pawh a theih bawk. Vector couple voltage tehkhin dan hian vector inkara angle (phase slip) chu a rualin a teh theih bawk a, chutih rual chuan turn ratio-te NO-load deviation chu % 0,5 . aia tlem emaw, a tlukpui emaw a ni tur a ni.