A chunga kan sawi tak insulation testing bakah hian switch lian leh circuit breaker te tan a hnuaia test te hi hman theih a ni.
A. Circuit breaker hun chhung-Travel thlirletna.
He test, medium leh high-a hman-voltage circuit breakers hian circuit breaker hnathawh dan tur a thawk tha em tih hriat theihna a pe a ni. He test hmang hian breaker hawn leh khar speed te, closing leh tripping hun chhung leh contact bounce te hriat theih a ni. He test hian harsatna, chak lohna chak lo tak tak, shock absorber chhia, dashpot, buffer, leh closing mechanism te ang chi harsatna hriat theihna tur information a pe a ni. Test hi mechanical device hmanga tih a ni a, chu chu breaker-ah a inzawm a ni. Device pakhat, rotating drum chart attached chu breaker-a chassis emaw tank emaw-ah hun eng emaw chen a inzawm a ni. Breaker-a lift rod portion-ah chuan marking device attached nei movable rod dah a ni. Breaker hawn emaw, khar emaw a nih chuan, marking device chuan drum chu speed hriat tawha a inher laiin chart-a contact travel zat a tarlang a ni. Device dang awm thei nen chuan movable rod-ah transducer an dah a, breaker operation chu oscillograph-ah record a ni.
Wuhan Huayi Electric Power chuan circuit breaker analyzer model number GKC-y a siam a, hei hian high-voltage circuit breaker voltage level hrang hrang, oil tlem zawk, oil tam zawk, vacuum leh sulfur hexafluoride te mechanical dynamic characteristics te chu dik takin a teh thei a ni.
B. Contact-resistance testing.
He test hi switch leh circuit breaker-a contact awmte quality test nan hman a ni. Chumi atana siam test set chu microHMS-a direct-scale calibration hmangin a awm a, contact resistance 10 microHMS emaw a aia tlem emaw chhiar thei a ni. Alternate method chu contact structures kaltlangin direct current level hriat tawh chu pass a, contacts zawng zawnga do millivolt drop tehna a ni. Chumi hnuah chuan data an hmuh chu OHM’s law hmangin resistance-ah an chantir thei a ni. Alternate method hian amperes 100 aia tlem lo, mill volt meter 0-20 mV vel awmna source a mamawh a ni.
Wuhan Huayi Electric Power chuan contact resistance tester a siam a, hei hian model hrang hrang 100A/200A/400A/500A/600A a nei a ni. 0.01μΩ resolution a nei a, printer-ah built- a nei bawk. Power leh power supply department-a high-voltage switch leh high-voltage switch plant-a circuit resistance testing-a ON-Site Maintenance-a thil tulte a tlin thei a ni. High leh low voltage switch contact (LOOP) resistance atan a tha a, cable line DC resistance value of high precision measurement atan pawh a tha a, current lian tak, micro resistance measurement occasion dang tan pawh a tha bawk.