HI-POT test hi dielectric-absorption test emaw step-voltage test emaw angin kan hmang thei a ni. DC high potential test te chu "go-No-go" test te an ni. Cable hi hun bituk chhunga voltage tarlan tawh chu tuar thei turin a mamawh a ni . Heng test-te hian a tlangpuiin field handling dik lo, accessories dik lo taka dah, emaw mechanical damage vangin harsatna lian tak tak a awm tih a tarlang ang. Test voltage rawt chu DO leh AC te tan standard table-ah tarlan a ni. Do hi-pot test tur chuan input voltage test set-a test tur a ni. Test equipment-a sensing circuit awm mekte chuan test mek cable nena inzawm leakage current chauh an teh tur a ni a, test equipment chhunga leakage awm chu a huam lo vang. Bulb leh dry wet record-bulb temperature emaw relative humidity leh temperature te record rawh. Wet bulb temperature chu thermometer bulb-in a pek temperature chu absorbent material (linen wet with distilled water) hmanga khuh a, boruak atanga expose a, chu chuan evaporation chuan tui leh thermometer bulb chu a ti lum ang. Dry-bulb temperature chu thermometer pangngaiin a pek boruak temperature tihna a ni. Cable section tin chu conductor dang zawng zawng grounded hmangin test vek tur a ni.
Shields zawng zawng pawh grounded vek tur a ni. Termination te chu guard ring, field reduction sphere emaw, a tul angin kawng remchang dang hmanga tihtawp tur corona tha tak a ni tur a ni. IEEE standard 48 emaw siamtute specification-a tarlan termination-te tan test voltage sang berin a huam chin a pelh loh nan fimkhur tur a ni. Dielectric absorption test anga hman a nih chuan second 60 atanga 90 chhungin a voltage sang ber chu zawi zawiin a hnawih zauh zauh a ni. Chumi hnuah chuan maximum voltage chu 5 .Minutes with leakage-Tunlai minute tin reading lak mek. Cable-ah chuan, ambient temperature sang emaw, .Cable siam dik loh tawp lama humidity chuan DO leakage current chu a normal value aiin a let tam takin a tisang thei a ni. Step-voltage test anga hman a nih chuan voltage sang ber chu a then chu a tlukpuiin a apply a ni.Increment, a tlangpuiin pariat aia tlem lo, voltage step tin chu hun bituk chhung atan vawn reng a ni.
Step inkar hun chhung chu a sei tawk tur a ni a, chu chuan leakage current chu stability a thlen theih nan, minute 1 emaw 2 vel a thleng thei ang. a leak .
Voltage chu level danga tihsan hmain interval tin tawp lamah current reading lak a ni.Test a kal zel chuan test voltage leh leakage current emaw insulation resistance emaw plot a awm a. ANINonlinear increase in leakage current hian failure lo thleng tur a tarlang thei a, test pawh tihtawp a ngai bawk.Test voltage sang ber a thlen hnuah chuan chu voltage-ah chuan dielectric absorption test tih theih a ni a,A tlangpuiin minute 5 chhung atan.
AC High-Thil tih theih dan tur test theihna .
Alternating-Tunlaia high-potential tests chu voltage-ah system voltage pangngai aia rei, hun rei lo te chhung, chutiang minute 1 chhung chu siam a ni. Test voltage hman tur chu device emaw circuit emaw a hniam emaw a voltage sang emaw, primary emaw control circuit emaw a zirin, factory-ah emaw, field-ah emaw test a nih leh nih loh a zirin a inang lo. Thil siamtute thupek leh a hman dan tur tehfungte chu hlutna dik tak nei turin zawhfiah tur a ni.
