Transformer oil tih dan tur dielectric strength test tih dan .

 Mar 21, 2025

 Message pakhat dah la .

 

Transformer oil dielectric strength test hian oil insulation performance chu a tha zawngin a ennawn thei a, transformer him taka hman theihna tur guarantee pawimawh tak a pe thei bawk.

Test dan: Dielectric Strength Tester hmang rawh .

Oil dielectric strength test tih dan tur step:
Electrode te chu tifai la, standard angin an inkar a awm ngei ngei tur a ni (a tlangpuiin 2.5 mm) a ni.
Oil sample chu test cup-ah theh lut la, chu chuan electrode chu oil chhungah a thun lut vek ang.
Oil sample a chhiat thlengin voltage chu constant rate-in tihpun tur a ni.
Breakdown voltage value chu record a ni a, average value chu vawi tam tak teh a ni tlangpui.
Standards: Test hian international emaw national emaw standard kaihhnawih, IEC 60156 emaw ASTM D877 emaw a zawm tur a ni.

Oil dielectric chakna atana influencing factor .
Moisture: Oil chhunga tui hian dielectric strength nasa takin a ti tlem a.
Thil bawlhhlawh: solid particle emaw fiber emaw ang chi bawlhhlawh te hian conductive channel a siam thei a, chu chuan a ti chhe thei a ni.
Temperature: Oil temperature sang lutuk emaw, a hniam lutuk emaw chuan test result a nghawng ang.
Aging: Oil a upa tawh chuan a insulation performance a ti tlem ang.

Result Oil Dielectric Strength Test hmanga zirchianna .
Dielectric strength value a san chuan oil insulation performance a tha zawk.
Test result chu standard value aia hniam a nih chuan oil chu filter emaw, dried emaw, thlak emaw a ngai thei.

Thil ngaihtuah ngai thilte .
Pawn lam atanga bawlhhlawh awm loh nan test environment chu fai taka dah tur a ni.
Uniformity a awm theih nan oil sample chu test hmain uluk taka hrual hmasa phawt tur a ni.
Test result chu oil quality indicator dang (moisture content, acid value, etc. ang chi) nen a inzawm tur a ni a, chu chuan rorelna zau tak a siam tur a ni.

Inquiry thawn rawh .
Inquiry thawn rawh .