Test transformer-a capacity chu engtin nge kan thlan ang?
HI-pot test neih chungchang sawi dawn chuan test transformer capacity hian hmun pawimawh tak a chang a ni. HI-pot test hian a tum ber chu electrical insulation-a chak lohna awm thei te hriatchhuah a ni a, test transformer rintlak tak chu result dik leh inmil tak neih theihna kawngah a pawimawh ber a ni. Test transformer-a capacity emaw, a mamawh voltage leh current pek theihna emaw chu i test-na mamawh tur unit dik tak i thlan hunah a pawimawh ber a ni.
I test transformer-a ideal capacity hriat chian nan thil engemaw zat i ngaihtuah a ngai a ni. A hmasa ber chu testing chhunga i tih tur voltage leh current sang ber a ni. He hlutna hi hmanrua chi hrang hrang test mek leh industry dan hman tur a zirin a innghat ang. Entirnan, damdawi hmanrua test nan transformer chuan high voltage leh current a mamawh zawk a, high-voltage electrical machinery test nan a hmang thei bawk.
Ngaihtuahna pahnihna chu transformer lian leh rit zawng zawng a ni. Test transformer atana hman tum dan azirin, device compact leh phurh awlsam emaw, high-volume testing atana lian zawk leh robust zawk emaw i mamawh mai thei.
Thil pawimawh dang ngaihtuah tur chu i test atana voltage output mamawh frequency hi a ni. Common test transformer te hian frequency 50 emaw 60 Hz ah an thawk a, mahse specialized equipment te hian voltage level duh ang siam chhuah leh test dik tak an tih theih nan frequency hrang hrang an mamawh thei a ni.
Tin, hmanraw rintlak leh dik tak siam chhuaktu nia hriat, siamtu hmingthang tak atanga test transformer thlan a pawimawh bawk. A well-designed leh high-quality test transformer hian i HI{-pot tests dikna leh himna nasa takin a ti tha thei a, electrical shock emaw thil hlauhawm dang emaw a awm theihna a ti tlem thei bawk.
Test transformer theihna thlan dan .
Nominal test transformer-a capacity PN tehna formula chu:
pn=KVN2WCT10-9 a ni.
n- Nominal test transformer theihna (KVA);
K - himna atana thil pawimawh;
VN- Test transformer (KV) a rated output voltage sang tak a hman tangkai theihna tur value tha tak a ni.
w - angular frequency, w=2πf,f chu test power supply frequency a ni a;
CT- subject capacitance (PF) 1.1.
Test voltage hrang hrang VN tan chuan Safety Factor K dik tak thlan a ni. Nominal test voltage a hniam chuan K value a sang thei. A hnuaia tarlan te hi test voltage VN hrang hrang, Safety Factor K value thlan tawh, reference atan a ni:
VN=50-100KV K=4;
VN=150-300KV K=3 a ni.
A tawpah chuan i test transformer capacity chu thil chi hrang hrangah a innghat ang a, chung zingah chuan i specific application-a voltage leh current mamawh te, transformer lian leh te, leh voltage output mamawh frequency te pawh a tel ang. Heng thilte hi uluk taka ngaihtuah a, thil siamtu rintlak leh hmingthang tak thlan hian i HI{-pot test te hi nang leh i thawktute tan a dik a, a him tih i tichiang thei ang.