VLF test hian engtin nge motor insulation tar tawh chu a evaluate thin?

 Mar 14, 2025

 Message pakhat dah la .

 

Very Low Frequency Testing (VLF Testing) hi motor insulation tar tawh dan tehna atana hmanraw tangkai tak a ni. Motor hnathawh laiin voltage stress chu ultra-insulation system a chhiatna emaw a upa tawh emaw hriat theihna turin Frequency hniam (a tlangpuiin 0.1Hz aia tlem) AC voltage hmangin a simulate a ni. A hnuaia tarlan te hi ultra-low frequency testing-in motor insulation aging a evaluate dan chipchiar taka hrilhfiahna a ni.

1. Test principle .
Ultra- hniam zawk frequency test hian frequency hniam AC voltage hmangin motor windings-ah electric field stress hmangin operating condition a simulate a.
Test chhunga current, voltage waveform, emaw partial discharge signal emaw enfiahin insulation system dinhmun chu a dik leh dik loh enfiah theih a ni.

2. Indicator hrang hrangte endik .
Current Change: Insulation aging hian leakage current a tipung ang a, test-a current inthlak dan enfiahin insulation aging℃chu a dik leh dik loh a enfiah thei ang.
Partial discharge: Insulation aging hi partial discharge phenomenon nen a inzawm fo thin a; VLF test hian discharge signal chakna leh frequency a hre thei a ni.
Voltage Waveform: Insulation defects hian voltage waveform distortion a thlen thei a, insulation state chu waveform inthlak danglamna thlirletin a teh theih bawk.

3. Test dan tur .
Inbuatsaihna: Motor power supply chu titawp la, safe grounding ensure la, test voltage leh frequency dik tak thlang rawh.
Voltage hman dan: Zawi zawiin ultra- hniam zawk frequency voltage chu preset value-ah (a tlangpuiin rated voltage aiin a let 1.5 atanga 2) in tisang la, hun engemaw chen (a tlangpuiin minute 15 atanga 30) chhung chu vawn tlat rawh.
Monitoring leh Analysis: Test neih chhung hian current, voltage waveform emaw partial discharge signal emaw record la, insulation status chu enfiah rawh.

4. Test result chu evaluate rawh .
Insulation pangngai: current nghet tak, voltage waveform distortion awm lo, partial discharge signal langsar lo.
Slight aging: current a sang deuh a, voltage waveform a inthlak tlem a, partial discharge signal a chak lo bawk.
Severe aging: current a pung nasa hle a, voltage waveform chu nasa takin a chhe a, partial discharge signal a chak bawk.

VLF test hmang hian motor insulation kum upa lam℃chu a kimchangin zirchian theih a ni a, chu chuan motor enkawl leh thlak theihna tur scientific basis a pe thei a, chu chuan hmanrua dam chhung a ti rei a, operation risk pawh a ti tlem thei a ni.

 