Tuna transformer hman mek .

 Nov 10, 2023

 Message pakhat dah la .

 

Instrument transformer hi chi hnih a awm a :
1.Tunlai transformer (a nih loh leh series transformer) .
2.Potential transformer (a nih loh leh parallel transformer) .
AC current magnitude chuan measuring instruments current safe value a pelh chuan current transformer hman a ni.
Potential transformer hi AC circuit voltage 750 V aia tam a nih chuan hman a ni a, hei aia voltage tehna hmanrua tehnaah hian insulation tling tak pek theih a nih loh avangin.
 
Tuna transformer (CT) awmzia sawifiahna .
1. CTs hi AC current value sang atanga value hniam zawka tihtlem / step down nan hman a ni a, chu chu tehna / venhimna / control atan a ni. Typical secondary current chu 5 A RMS a ni.
..
 
Hnathawh dan tur (working principle ) .
1.A CT hian electrical power transformer hnathawh dan bulpui inang a nei a mahse hetah hian danglamna engemaw zat a awm.
Electrical power transformer emaw general purpose transformer dang emaw a nih chuan primary current chu load emaw secondary current emaw a zirin a danglam thin.
2.Ct a nih chuan primary current chu system current a ni a, he primary current emaw system current hi CT secondary ah a inthlak a, chuvangin secondary current emaw burden current chu current transformer primary current ah a innghat a ni.
 
CT a tihsual chhan .
in Ideal CT ah chuan .
Actual transformation ratio KC=Turn ratio KT leh phase angle chu zero a ni ang. Mahse electric leh magnetic CKT-a taksa lama harsatna awm vangin tihsual a awm thin.
A chhan:
1.ct chuan magnetising current IM a draw a, chu chuan primary winding-in a mamawh MMF ngaihnawm tak a pe a, chu chuan flux a siam chhuak thei a ni.
2.CT hian core loss (eddy current leh hysterisis loss) supply turin energy current a la a +electrical I2R hloh. Chutiang chuan energy hloh component .
IE hi primary winding-a current IO ngaihnawm tak avang hian winding-a flux leh a kaihhnawih culoss nena inzawm loss supply turin a ngai a ni.
3.Flux density in core hi magnetising force linear function a ni lo. Chutiang chuan CT core chu a saturate ta a ni.
4.Magnetic leakage a awm fo thin .

 

Current transformer a error awm tlem dan .
1. Permeability sang leh hysteresis loss magnetic materials core hmanga siam.
2. Rated burden chu burden tak tak value hnaih zawka dah.
3. Flux path sei ber leh cross-sectional area of ​​core tihpun, joint of core tih tlem.
4. Secondary chhunga impedance tihhniam .
 

Tuna transformer hman mekte test dan .

Type Tests chu IS angin a awm a.
A hnuaia test te hi Type Test 1000 a ni.
A) Terminal marking leh polarities te finfiah .
b) Short-Hun hman mek test .
c) Temperature sang test .
d) Primary-a impulse voltage test .
e) Primary-a power frequency voltage tuar thei test .
f) Thil dik lo tehna .
g) Overvoltage Inter-Turn Test neih tur a ni.
Routine Tests chu IS angin .
A hnuaia test te hi individual CT tin ah hman a ni .
A) Terminal marking leh polarities te finfiah .
b) voltage power sang tak-frequency voltage tuar thei tur test chu secondary-ah a awm.
c) Inter-Turn overvoltage test a ni.
d) Thil dik lo hriatfiahna leh dikzia class .
--- Test order chu standardized a ni lo va, mahse test dang hnuah tihsual tihfel a ni ang
Test bik 1.1.

 

A hnuaia test te hi 1999 inkara inremna siam a nih chuan tih a ni.
A siamtu leh a lei tu:
a) Lightning impulse test 2019.
b) Capacitance leh dielectric dissipation factor tehna .
c) Primary winding-a impulse test tam tak neih theih a ni.
d) Mechanical test 10.1.
e) -voltages hmanga transmitted tehna .
 

Wuhan Huayi Electric Power Technology chuan tunlai transformer chi hrang hrang test equipment a siam chhuak mek a, a siam mek bawk. Kan thil siam tha tak tak leh proffional solution kan pe che a ni. I CTS te kha humhim la, enkawl rawh.

Inquiry thawn rawh .
Inquiry thawn rawh .