Circuit breaker leh transformer te chu GIS system ah hman a ni.

 Jul 10, 2024

 Message pakhat dah la .

 

Circuit breaker AIS leh GIS te hian a bul berah chuan dead tank chi khat SF6 puffer circuit breaker an hmang a. Mahse, GIS system hmang chuan SF6-to-air bushings circuit breaker enclosure-a dah ai chuan GIS circuit breaker chu a kianga awm GIS module-ah direct-in a inzawm a ni.

 

GIS application-te tana current transformersCurrent transformer te chu device an ni a, chu chu conductor atanga high-Thil chu standardized, equivalent value-a chantirna tur insubstation dah a ni a, chu chu metering, measuring leh protection atan hman a ni. Installation location - AGIS system-a dah mek transformer awm mekte chu inductive-ring type a ni a, GIS enclosure chhung emaw pawnah emaw dah theih a ni. Transformer secondary winding lam ah metering leh protection - an ti a. GIS conductor chu tuna transformer unit awm mek tan chuan single-Turn primary a ni.

 

Enclosure chhunga - chhunga dah current transformer-te tana ngaihtuah tur CTs-te chu high-voltage conductor-in a siam chhuah electric field-ah a venghim tur a ni a, chutiang a nih loh chuan heng secondary winding-ah hian capacitive coupling hmangin high transient voltages a lang thei a ni. Enclosure pawn lama CTs dah - Enclosure ngei pawh hian insulating joint a nei tur a ni a, enclosure currents te chuan CT chu an shuntedaround tur a ni. Heng GIS siam chi pahnih hi hman a ni nasa hle.

 

CTS atanga digital output signal - analog relaysadvanced CT chi hrang hrang te chu space humhim nan leh GIS man tihtlem nan an siam a, magnetic core emaw Rowgowski coil emaw chu paih chhuah a ni. Heng CT unit chi hrang hrang output signal te hi level hniam takah an awm a, chu chuan enclosure-mounted device hmangin, digital signal-ah a chantir nghal thei a ni. Signal chu digital a nih tawh chuan wire emaw fiber optic cabling hmangin hla tak takah, control emaw protective relay emaw hmangin a kal thei a ni. Thupui pakhat erawh chu, utility-te hman mek protective relay tam tak chuan relay hian conventional analog signal chu digital-ah a chantir thei a, mahse, process hmain digital input a pawm lo tih hi a ni.

 

GIS hmanna atana hman voltage transformer voltage transformer (VTs) te hi iron core nei inductive type an ni. VT hi a tlangpuiin sealed unit a ni a, gas barrier insulator a awm bawk. Installation option 1 - VT hi awlsam takin removable a nih avangin GIS chu a sang thei-Voltage tested within the unit the unit.Installation option 2 - VT hi disconnect switch emaw removable conductor link emaw hmanga pek a ni. Primary winding - chu SF6-a insulating plastic film-a thun a ni.Transient voltage - capacitive coupling ven nan VT hian primary leh secondary windings inkarah electric field shield a nei tur a ni.

Inquiry thawn rawh .
Inquiry thawn rawh .