Capacitance leh dissipation factor test te hi power transformer te tana diagnostic tools pawimawh tak a ni. Heng test te hian transformer insulation condition hriat theihna a pui a, hei hi beisei loh taka hlawhchhamna venna atana pawimawh tak leh transformer hnathawh leh dam chhung tih that nan a pawimawh hle.
Capacitance hi transformer-in electrical charge voltage bik a dah theihna tehna a ni. Test-ah hian winding leh ground tin inkar capacitance tehna a awm a, chutiang bawkin winding hrang hrang inkar a ni bawk. Hun kal zelah capacitance inthlak danglamna hian insulation aging emaw, transformer chhunga moisture emaw contaminant dang emaw a awm tih a tilang thei a ni.
Dissipation factor, Tan Delta tia hriat bawk hian insulation material-a power hloh zat a teh a ni. He hloh hian transformer a ti lum thei a, a tichhia thei bawk a, chuvangin dissipation factor level enfiah a pawimawh hle. Test-ah hian transformer-ah AC voltage hman a, power hloh zat ratio chu insulation-a dah energy ratio teh a ni.
Capacitance leh dissipation factor test pahnih hi specialized test equipment hmangin a rualin tih theih a ni. He hmanrua hian low-frequency AC voltage a siam a, transformer windings inkar current leh phase angle a teh bawk. Capacitance leh dissipation factor value te chu industry standard nen khaikhin chuan technician te chuan transformer-in a insulation condition zawng zawng a teh thei ang.
Transformer’s insulation chu hun kal zelah thermal cycling, moisture, leh environment thil dang avang hian a chhe thei a ni. Chu bakah, thil siamna lama chhiatna emaw, dah dik loh emaw chuan a tir atang khan insulation problem a thlen thei bawk. Insulation a chhiat chuan downtime man to tak, transformer tihchhiatna, leh hnathawk leh hmanrua te tan pawh dinhmun hlauhawm tak tak thlengin a thlen thei a ni.
Capacitance leh dissipation factor test tih fo hian transformer neitute leh operator-te chuan an hmanrua hriselna chungchangah hriatna hlu tak an nei thei a, hlawhchhamna tur venna kawngah hma la hmasain an ti thei bawk. Entirnan, test-te hian dissipation factor sang tak a lantir a nih chuan transformer chu oil purged, dried, emaw re-insulated a ni thei a, chu chuan a performance a ti tha thei a ni. Chutiang bawkin, hun kal zelah capacitance value te chu a inthlak danglam a nih chuan, transformer chu a chhiat theihna tur hlauhawmah a awm a, ngun zawka enkawl a ngai tih a tilang thei a ni.
HUAYI developed the capacitance and dissipation factor tester which has multiple test modes:It can test by internal high voltage, external high voltage, internal standard,external standard, positive connection method, reverse connection method, self-excitation method and other methods;High voltage (>10KV) External standard external high voltage dinhmun hnuaiah dielectric loss siam theih a ni. CVT test:CVT(capacitor voltage transformer)C1/C2 hmangin dielectric hloh leh capacitance a test thei a, C1/C2 chu a rualin a test thei bawk. CVT variation ratio leh voltage angle danglamna pawh a test thei bawk.
Capacitive leh dissipation factor test te hi power transformer rintlak leh him taka hman theihna tura hmanraw pawimawh tak a ni. Insulation dinhmun enfiah a, harsatna awm thei te chu a pawimawh em em hmaa hriatchhuah a nih chuan, transformer neitute leh operator-te chuan sum an humhim thei a, hun an humhim thei a, dinhmun hlauhawm an veng thei bawk.