Secondary circuit impedance chu ohms-ah a lang a, power factor angle chu burden an ti a. Mahse a tlangpuiin KVA-a apparent power leh specified power factor-a secondary current rated-a tarlan a ni. He power factor hi CT-a secondary current-a power factor a ni lo.
Rated ‘burdens’ of CTs and VTs hian volt-amperes (VA)-a load sang ber, secondary terminal-a hman theih tur, ratio leh phase angle error awm lo, permissible limits aia tam lo chu a kawk a ni. phurrit chu instrument emaw relay emaw inzawm zat leh an mimal phurrit typical value-ah a innghat a ni.
CT terminal chhinchhiahna:
Terminal marking-ah chuan:
a) Primary leh secondary windings te.
b) Winding section te, a awm chuan.
c) winding leh winding section hrang hrangte inzawmna (relative polarities); leh
d) Intermediate tappings, a awm chuan.
CT hmanga chhinchhiahna siam dan: 1.1.
1. Terminal-te chu an leihnuaiah emaw, a chungah emaw chiang tak leh thahnemngai taka chhinchhiah tur a ni.
an hnaih berna hmun.
2. Marking-ah hian letter zawm tur a awm tur a ni a, a nih loh leh a tulna hmunah chuan a hmasa ber tur a ni ang.
numbers te chu a ni. Lehkha te chu block capital-ah a awm ang.
3. P1, S1 leh C1 tih ziak terminal zawng zawng hian eng polarity inang an nei vek tur a ni.
chawpchilh.
Magnetization curve: - a ni.
CT-a magnetization curve-ah hian typical oriented electrical steel-a excitation characteristic curve a awm a. Excitation curve hi ankle point atanga ankle point (II) thlenga ankle point atanga ankle point (II) thlenga khup (iii) knee region (IV) saturation region thlenga chi hrang hrang lian pali (I)-ah then theih a ni. Knee point tih hi flux density 10% a san chuan ampere ngaihnawm tak 50% a tihpunna hmun a ni tihna a ni-turns tihna a ni.
Protective current transformer hian a tlangpuiin over-ankle atanga a chunga knee region thlenga inzar pharh flux density of flux density range a thawk a, measuring current transformer erawh chuan ankle awmna region-a flux density chauh a nei thung.
Saturation hmain core-a flux density chu ampere-turns nen a inzat a ni. Saturation a thlen chuan magnetizing inductance chu a hniam a, total primary current chu a core exciting chauh ah hman a ni a, chuvangin CT secondary output chu a bo ta a ni.
Saturation chu primary transient current chu saturation level aia hniam a nih thlengin a kal zel a. Saturation zone-a energy chungchangah chuan CT chu open circuited a ni. Short-circuit conditions laiin saturation awm loh a harsa. Saturation effect chu output tihtlem a ni a, chuvang chuan over-current relays speed tihhniam a ni. Differential relay-ah chuan saturation hian balance a tibuai a, venhimna stability a nghawng bawk.
Current transformer saturation curve hi secondary Volts vs.-ah plot a ni tlangpui a, secondary-a teh a ni. Secondary voltage mamawh magnitude atan chuan saturation℃chu curve atang hian hmuh theih a ni a, he voltage siam chhuahna tur hian exciting current magnitude hmangin a lang bawk.